Heltun HE-ZW-THERM-FL1 Скачать руководство пользователя страница 11

1 – Degree Mode 

 

Value 

Description 

How to Read and Write 

Dec 

Hex 

Available 
settings 


0x00 
0x01 

°C – Celsius 

°F – 

Fahrenheit 

Read:

 Command = CONFIGURATION_GET 

Parameter Number = 1 (0x01) 
Report is returned. 

Write:

 Command = CONFIGURATION_SET 

Parameter Number = 1 (0x01) 
 

Default settings 

0x00 

°C 

Parameter size:

 1 byte 

 
2 – Source Sensor 

 

Value 

Description 

How to Read and Write 

Dec 

Hex 

Available 
settings 







0x00 
0x01 
0x02 
0x03 
0x04 
0x05 
0x06 

F – Floor sensor 
FA – Floor+Air sensors 
A – Air sensor 
AF – Air+Floor sensors 
P – Time regulation 
PF – Time+Floor sensor 
PA – Time+Air sensor 

Read:

 Command = CONFIGURATION_GET 

Parameter Number = 2 (0x02) 
Report is returned. 

Write:

 Command = CONFIGURATION_SET 

Parameter Number = 2 (0x02) 
 

Default settings 

0x00 

Parameter size:

 1 byte 

 
3 – Power Regulation ON time 

 

Value 

Description 

How to Read and Write 

Dec 

Hex 

Available 
settings 

10 

90 

0x0A 

0x5A 

Minutes 

Read:

 Command = CONFIGURATION_GET 

Parameter Number = 3 (0x03) 
Report is returned. 

Write:

 Command = CONFIGURATION_SET 

Parameter Number = 3 (0x03) 

Default settings 

15 

0x0F 

15 min 

Parameter size:

 1 byte 

 
4 – Power Regulation OFF time 

 

Value 

Description 

How to Read and Write 

Dec 

Hex 

Available 
settings 

10 

90 

0x0A 

0x5A 

Minutes 

Read:

 Command = CONFIGURATION_GET 

Parameter Number = 4 (0x04) 
Report is returned. 

Write:

 Command = CONFIGURATION_SET 

Parameter Number = 4 (0x04) 

Default settings 

15 

0x0F 

15 min 

Parameter size:

 1 byte 

 
5 – Air Temperature Minimum 

 

Value 

Description 

How to Read and Write 

Dec 

Hex 

Available 
settings 

40 

360 

0x28 

0x0168 

(Value/10), 
Temperature in 
Celsius 

Read:

 Command = CONFIGURATION_GET 

Parameter Number = 5 (0x05) 
Report is returned. 

Write:

 Command = CONFIGURATION_SET 

Parameter Number = 5 (0x05) 

Default settings 

210 

0xD2 

21.0

°

Parameter size:

 2 byte 

 

Содержание HE-ZW-THERM-FL1

Страница 1: ...FLOOR HEATING THERMOSTAT HE ZW THERM FL1 USER MANUAL...

Страница 2: ...in room air temperature sensor The thermostat is also equipped with built in humidity and energy consumption sensors The thermostat has a built in 5th generation Z Wave module which allows to integrat...

Страница 3: ...ork 4 operation modes ECO GEN DRY MANUAL Choosing a temperature sensor for operation Floor temperature only Air temperature only Floor Air temperature Power regulator Automatic ON OFF timer Time cycle...

Страница 4: ...o the wall mounting box using the screws provided Install the thermostat body by carefully aligning the top snap connectors and then pushing on the front cover with gentle pressure ensuring it snaps f...

Страница 5: ...table MODE This mode is recommended for normal comfort Factory default set point is 25 0 C 77 F Minimum set point is 4 0 C 39 F Maximum set point is 37 0 C 99 F ECO energy saving MODE You can use this...

Страница 6: ...02 SEn Source Sensor F F FA A AF P PF PA 03 Pon Power Regulation ON time min 15 10 90 04 PoF Power Regulation OFF time min 15 10 90 05 AIL Air Temperature Minimum C F 21 70 4 36 in Celsius mode 39 99...

Страница 7: ...aram 03 Pon and then OFF during the time in Param 04 Pof 6 PF Power regulator Floor sensor parameters Parameter is heating time set by Params 03 and 04 but also controlled by the floor temperature sen...

Страница 8: ...r 08 FLH Floor Temperature Maximum Floor temperature high limit Reading of the external floor temperature sensor It has effect only if AF or PF are selected as the source sensor Factory default value...

Страница 9: ...ines the brightness level of the display in the inactive state You can select the level from values 1 to 4 but the level cannot be higher than the level of brightness for the active state Default valu...

Страница 10: ...r appear in the value position then the inclusion was not completed Note In case the device has been part of a system before and not excluded since inclusion is not possible In this case exclusion mus...

Страница 11: ...3 Power Regulation ON time Value Description How to Read and Write Dec Hex Available settings 10 90 0x0A 0x5A Minutes Read Command CONFIGURATION_GET Parameter Number 3 0x03 Report is returned Write Co...

Страница 12: ...How to Read and Write Dec Hex Available settings 50 370 0x32 0x0172 Value 10 Temperature in Celsius Read Command CONFIGURATION_GET Parameter Number 8 0x08 Report is returned Write Command CONFIGURATIO...

Страница 13: ...Available settings 5 95 0x5 0x5F Value 10 in Celsius 0 5 C to 9 5 C Read Command CONFIGURATION_GET Parameter Number 13 0x0D Report is returned Write Command CONFIGURATION_SET Parameter Number 13 0x0D...

Страница 14: ...ure setpoint used in DRY mode Value 10 in Celsius 4 0 C to 37 0 C Read Command Class COMMAND_CLASS_THERMOSTAT_SETPOINT Command THERMOSTAT_SETPOINT_GET Type Dry air 0x08 Report is returned Write Comman...

Страница 15: ...0x01 0x08 0x0B OFF GEN DRY ECO Read Command Class COMMAND_CLASS_THERMOSTAT_MODE Command THERMOSTAT_MODE_GET Report is returned Write Command Class COMMAND_CLASS_THERMOSTAT_MODE Command THERMOSTAT_MODE...