TEAM GENERATOR AND AUXILIARY PARTS INSTALLATION:
The
control panel
can also be installed inside the steamroom. If the control panel is installed
outside the steamroom or so low that its own thermostat will not display the proper temperature, a
separate thermostat must be used, which is connected directly to the circuit board and installed 170
cm above floor level, preferably on the wall opposite the steamroom door.
The push button
can be fitted either in the steam room or outside of it. In addition it is also
recommended to install a limiting thermostat to prevent the rise of the temperature above +50 °C
when the steam room is used for longer than 30 minutes, which is the fixed operating time of a
steamer equipped with a push button. See the separate installation and connection picture.
The
steam nozzle(s)
are installed approx. 20 – 40 cm above floor level under the bench or seat, or
on the wall, making sure that the hot steam does not burn your feet. When placing the nozzles, also
make sure that they will not be touched accidently.
The steam temperature is + 100 °C
and can
cause severe burns.
The thermostat
is installed at a height of 170 cm, preferably on the wall opposite the door.
The installation space for the thermostat should also be sealed with a suitable material to prevent the
seeping of moisture into the structure. The thermostat is connected directly to the steamer circuit
card and its program will automatically incorporate it, see the connection picture.
Water connection
400V 3N~
Discharge
Temperature sensor
Control panel
Steam nozzle
OK
ON OFF
OK
ON OFF