OPERATION AND INSTALLATION:
The HSX steam generator is only intended for use in the heating of steambaths. Use of the steam
generator in any space other than intended can result in structural damage.
The manufacturer is not liable for any damages caused by installation in a space not inlended for
steambath use, or misure of the generator.
Before connecting the steam generator to the mains power, connect all water and steam lines. All
lines must be connected with the greatest care. Ensure that all joints are properly sealed. Although
thread seal tape can be used to properly seal threaded joints, soldering the joints is recommended.
The steam generator should be placed away from water and moisture (dry space). The space should
be well-ventilated, as the steam generator also generates heat. The minimum recommended safety
clearance on each side and above the generator is 30 cm. When placing the steam generator, also
take into consideration the space required for its maintenance.
Ensure that there is a drain in close proximity to the steam generator for discharging the tank.
The steam generator can be mounted on the floor (free standing) or on the wall using mounting
brackets. When using wall brackets, use a fastening method and mounting screws appropriate to the
wall material in question. When filled with water, the steam generator weighs approx. 17 kg.
If the automatic discharge valve is being used, a wall-mounting is recommended to ensure the
proper discharge pressure in the discharge pipe leading into the drain.
HSX M installation
The control panel can be mounted either inside or outside the steamroom. If the control panel is
mounted outside the steamroom, a separate thermostat connected to the circuit board
must always
be used.
Water connection
400V 3N~
Discharge
Temperature sensor
Control panel
Steam nozzle
OK
O N OF F
OK
O N OF F
Button
Location of control panel and button Steam generator wall mounting