Technical specifications: 

 

Voltage: 400V – 415V 3N~ 50Hz (230V – 240V 1N~ 3.4 – 7.7 kW).

 

 

Power alternatives: 3.4kW-14kW.  

 

Enclosure rating: IP 20.  

 

Installation mounting: Floor/Wall. 

 

Water tank material: Aisi 316, acid-resistant steel. 

 

2-phase control for thermal resistance. (Not in the special Belgian version) 

 

Steamer dimensions: 520 x 380 x160 mm 

 

 

Easy to use: 

 

Automatic discharge and flush programme. 

 

Automatic fill and water level control. 

 

Floor or wall mounting. 

 

Digital control panel. 

-

 

Temperature control 

-

 

Time setting 

-

 

Light control 

 

Control panel can be installed inside the steamroom. 

 

Magnetic valve equipped with a large discharge port, allowing larger contaminants and lime 
deposits to be flushed from the tank after each use. (Accessory) 

 

 

Easy to maintain: 

 

Replaceable resistors (3 pcs), 1 of which is equipped with a thermal fuse. 

 

Lime remover (citric acid) fill port is conveniently located on top of the steam generator. 

 

Components can be easily replaced: 

            - Circuit board 
            - Thermal resistors 
            - Surface level sensor 
 

 

 
 
 
 
 

Содержание HSX M 120

Страница 1: ...M New HELO HSX M steam generator for home and professional use Operating instructions Installation instructions Operating and installation instructions for models HELO HSX M 34 47 60 77 95 120 140 701...

Страница 2: ...ill and water level control Floor or wall mounting Digital control panel Temperature control Time setting Light control Control panel can be installed inside the steamroom Magnetic valve equipped with...

Страница 3: ...enerator is 30 cm When placing the steam generator also take into consideration the space required for its maintenance Ensure that there is a drain in close proximity to the steam generator for discha...

Страница 4: ...room NO drainage traps water pockets may be installed on the line any water condensation forming in the steam line must be able to run freely into the steamroom or back into the steam generator If an...

Страница 5: ...ilation must also be given extra power The required power output can be estimated using the fomula below Volume m3 x K1 x K2 Required output kW Ventilation K1 0 75 No ventilation K1 0 52 Acrylic walls...

Страница 6: ...N 3 N N N N N V2 V1 H1 H2 N L PE OLEA 72 S1 S2 Lower limit Upper limit Water valve discharge 230 V AC Water valve fill 230 V AC Resistors Contactor LC1 LC2 B1 B2 T1 T2 A K S1 S2 TX RX 5 0 Serieal traf...

Страница 7: ...0 354 SHS 31 A 1 5 2 6 Levelprobe in Tank Main switch Top cover Lower limit Upper limit Water valve discharge 230 V AC Water valve fill 230 V AC Thermo fuse Resistors Contactor Serieal traffic MIDI co...

Страница 8: ...N 1 2 3 6 4 5 3 4 7 7 kW 230 V 1N 2 L1 N L2 1 2 3 6 4 5 3 4 14 kW 400 V 3N L1 L2 L3 Level probe N N N N V2 V1 H1 H2 N L PE OLEA 72 S1 S2 Low level High level Water valve drain 230 V AC Water valve fil...

Страница 9: ...ng time of a steamer equipped with a push button See the separate installation and connection picture The steam nozzle s are installed approx 20 40 cm above floor level under the bench or seat or on t...

Страница 10: ...selector button time display flashes button increases both time setting and temperature value button decreases both time setting and temperature value Light control button opto switch max 24 V DC 50...

Страница 11: ...n is pressed the circuit board transistor will transfer power to connector LC2 which controls the actual lighting unit BUTTON HSX M Button function Turning on the steam generator with the button will...

Страница 12: ...remove the frame use the included tool The frame has small holes around its edges 4 Using the tool lightly press the locking pin in each hole and then pull the frame out The button is filled with mas...

Страница 13: ...hing on or with the steam generator already running the water faucet is shut or water is for some other reason being prevented from flowing into the steam generator Turn on the water faucet If the fau...

Страница 14: ...hake off the excess water After one minute compare the colour of the strip with the colour code on the package Test result 3 dH Very soft water Lime removal once every 500 operating hours 4 dH Soft wa...

Страница 15: ...turn on again and refill the tank with water The generator shuts down again and discharges and flushes again after 15 minutes This can be repeated about 3 5 times Manual discharge valve After boiling...

Отзывы: