background image

TNT Physical Specifications

DEALER NAME:

 

 

 

RECOMMENDED BRINE TANK 

MINERAL TANK 

APPROXIMATE

 

PIPE SIZE 

MINERAL TANK 

SIZE 

SALT STORAGE 

GRAVEL UNDERBEDDING 

SHIPPING WEIGHT

 

MODEL 

(INCHES) 

(INCHES) 

(INCHES) 

( LBS) 

1/4" X 1/8" 

#20 

SINGLE 

TWIN

 

TNT-300-24 

24 X 72 

30 X 50 

1,110 

150 

1085 

2145

  TNT-300-30 

30 X 72 

30 X 50 

1,110 

200 

75 

1160 

2295

  TNT-450-30 

30 X 72 

39 X 48 

2,030 

200 

75 

1600 

3120

  TNT-450-36 

36 X 72 

39 X 48 

2030 

300 

150 

1835 

3590

  TNT-600 

36 X 72 

39 X 48 

1,640 

300 

150 

2115 

4135

  TNT-750 

42 X 72 

42 X 60 

2,580 

500 

175 

3475 

6325

  TNT-900 

42 X 72 

50 X 60 

4,130 

500 

175 

4280 

8560

  TNT-1200 

48 X 72 

50 X 60 

3,495 

700 

200 

4800 

8760

Mineral tank sizes shown are with composit/FRP tanks.

 

 

RATED CAPACITY 

 

FLOW RATES (gpm)

 

 

RESIN 

LOW SALT 

MEDIUM SALT 

HIGH SALT 

 

  

 

BKW

 

MODEL 

CU.FT. 

GRAINS/LBS 

GRAINS/LBS 

GRAINS/LBS 

15 PSI 

25 PSI 

GPM

 TNT-300-24 

10 

190,000/60 

280,000/100 

320,000/150 

120  

170 

12

 TNT-300-30 

10 

190,000/60 

280,000/100 

320,000/150 

175  

225 

20

 TNT-450-30 

15 

285,000/90 

420,000/150 

480,000/225 

158  

212 

20

 TNT-450-36 

15 

285,000/90 

420,000/150 

480,000/225 

200  

278 

30

 TNT-600 

20 

380,000/120 

560,000/200 

640,000/300 

189 

257  

30

 TNT-750 

25 

475,000/150 

700,000/250 

800,000/375 

212 

280 

40

 TNT-900 

30 

570,000/180 

840,000/300 

960,000/450 

215 

282 

50

 TNT-1200 

40 

760,000/240 

1,120,000/400 

1,280,000/600 

213 

280 

50

TNT Capacity Ratings

1.  Steel tank design configurations available up through 60” tank diameters.  Consult factory for details.

OPERATING CONDITIONS

1. Water Pressure 30 - 100 psi.

2. Water temperature is not to exceed 110°F and the unit cannot be subject to freezing conditions.  Consult factory for higher water  

  temperature applications.

3. Limit of 2 ppm of Ferrous Iron. Add 3 grains per gallon of hardness for each ppm of iron present.

4. Flex connectors and vacuum breakers are required when using the PolyGlass Composite mineral tanks.

5. Backwash flow rates are calculated at 4 gpm per sq. ft. of bed area and rounded off based on 50ºF water temperature.

TNT Series Fiberglass Dimensions

 

with Six-Inch Flange Opening

73-054

9/08-LBRY

TNT-300-24 

101 

87.5 

82.5 

51 

62 

99

TNT-300-30 

101 

87.5 

80 

51 

68 

108

TNT-450-30 

112 

96.5 

80 

51 

83 

117

TNT-450-36 

112 

97 

81 

51 

83 

129

TNT-600-36 

112 

97 

81 

51 

83 

129

TNT-750-42 

113 

104.5 

92 

51 

92 

144

TNT-900 

113 

104.5 

92 

51 

92 

144

TNT-1200-48 

116 

103 

93 

51 

106 

164

All dimensions ±1” and are subject to change without notice.  Use as reference only.

*Allow additional 12” for resin filling on HT dimension.

**Allow additional 18” for resin filling on HS dimension.

Call factory for optional tank & dimensional configurations.
Product Improvement designs are subject to change without notice.

HELLENBRAND, INC.

1-800-626-1417

www.hellenbrand.com

 

 HEIGHT 

INLET/OUTLET HEIGHTS  SUGG. WIDTH

 

  

TOP MOUNT  SIDE MOUNT  TOP MOUNT SIDE MOUNT  SINGLE  TWIN

 

MODEL 

HT* 

HS** 

IT 

IS

Содержание TNT Series

Страница 1: ...Buildings Boiler Water Treatment Car Washes Commercial Buildings Condominiums Factories Hospitals Laundries Mobile Home Parks Motels and Hotels Nursing and Rest Homes Office Buildings Restaurants Schools For Commercial Industrial Applications ...

Страница 2: ...t Outlet FRONT VIEW BACK VIEW 8 Heavy duty Drive Motor receives signal from timer to efficiently direct water flow during regeneration Piston shifts smoothly and quietly regardless of water pressure 9 Lower Heavy duty Drive Motor receives signal from upper drive motor to direct the service piston into posi tion Piston shifts smoothly and quietly regardless of water pressure 10 TNT Series Timer pro...

Страница 3: ...rs between last two regenerations Hours since last regeneration Adjustable volume remaining Valve position 3200NXT Electronic Controller 3 Twin Tri Plex Four Plex Demand Recall Progressive Systems 3214NXT Controller 2 4 Units Individual Meters Single or Individual Brine Systems Three programming levels User mode Master programming Diagnostics mode Note The 3214NXT Demand Flow Network Controller is...

Страница 4: ...ONAL SAFETY BRINE VALVE Acts as a Second ary Shut Off for Timed Brine and may be used as a Primary Shut Off without Timed Brine TNT Series Typical Single Tank Installation Twin Alternating Tank Installation Available with individual brine tanks as shown or with one twin brine tank TOP VIEW Note 1 Optional stainless steel flex connectors are available for the inlet and outlet connection with each s...

Страница 5: ...actory Where ceiling heights may pose a restriction or a side mounted configuration is preferred TNT Series systems are available in this design configuration Factory pre piped and pressure tested these system designs must be shipped either skid mounted or have face piping dis assembled for shipment and re assembled at the job site Available with non corrosive polyglass composite tanks or steel Co...

Страница 6: ...ervice Rates Pressure Drop Chart 11 92 TNT 300 3 Service Rates Pressure Drop Chart 11 92 FLOW RATE G P M FLOW RATE G P M TNT 450 3 Service Rates Pressure Drop Chart 11 92 FLOW RATE G P M FLOW RATE G P M TNT 750 3 Service Rates Pressure Drop Chart 11 92 ...

Страница 7: ... epoxy resin Rustproof and corrosion resistant Operating Parameters Maximum operating pressure 150 PSI 10 2 BAR Maximum operating temperature 120ºF 49ºC Industry Approved Tanks designed and tested to meet industry standards ensuring top field performance NSF Standard 44 Warranty Allcommercial lightindustrialtanksarebackedbyanexclusivelimitedmanufacturer s warranty Sizes 24 through 48 5 year limite...

Страница 8: ...0 000 600 213 280 50 TNT Capacity Ratings 1 Steel tank design configurations available up through 60 tank diameters Consult factory for details OPERATING CONDITIONS 1 Water Pressure 30 100 psi 2 Water temperature is not to exceed 110 F and the unit cannot be subject to freezing conditions Consult factory for higher water temperature applications 3 Limit of 2 ppm of Ferrous Iron Add 3 grains per ga...

Отзывы: