background image

SideMount

 

2” Meter and Flow/Pressure Loss Data 

■  

Standard Range 1,250 Gal. Min. to 21,250 Gal. Max. 

■  

Flow accuracy –– 

+5% from 3 to 150 GPM

■  

Extended Range 6,250 Gal. Min. to 106,250 Gal. Max. 

■  

Dimensions & Flow Data are the same with NT Microprocessor

3” Meter and Flow/Pressure Loss Data

■  

Standard Range 3,750 Gal. Min. to 63,750 Gal. Max. 

■  

Flow accuracy –– 

+5% from 7 to 300 GPM

■  

Extended Range 18,750 Gal. Min. to 318,750 Gal. Max. 

■  

Dimensions & Flow Data are the same with NT Microprocessor

■  

Other meters available, consult factory 

Where ceiling heights may pose a restriction or a side-mounted configuration is preferred, TNT Series systems are available in this 

design configuration.  Factory pre-piped and pressure tested, these system designs must be shipped either skid mounted or have 

face piping dis-assembled for shipment and re-assembled at the job site.  Available with non-corrosive polyglass composite tanks or 

steel.  Consult factory for details.

2” Meter

 

3” Meter

 

Optional skid mounted system 

design  configurations  with  or 

without factory interconnecting 

piping for twin or tri-plex system 

designs  are  available,  in  both 

top-mount or side-mount design 

configurations.

Skid mounted and 

factory pre-piped

2” Brass Meter

Содержание TNT Series

Страница 1: ...Buildings Boiler Water Treatment Car Washes Commercial Buildings Condominiums Factories Hospitals Laundries Mobile Home Parks Motels and Hotels Nursing and Rest Homes Office Buildings Restaurants Schools For Commercial Industrial Applications ...

Страница 2: ...t Outlet FRONT VIEW BACK VIEW 8 Heavy duty Drive Motor receives signal from timer to efficiently direct water flow during regeneration Piston shifts smoothly and quietly regardless of water pressure 9 Lower Heavy duty Drive Motor receives signal from upper drive motor to direct the service piston into posi tion Piston shifts smoothly and quietly regardless of water pressure 10 TNT Series Timer pro...

Страница 3: ...rs between last two regenerations Hours since last regeneration Adjustable volume remaining Valve position 3200NXT Electronic Controller 3 Twin Tri Plex Four Plex Demand Recall Progressive Systems 3214NXT Controller 2 4 Units Individual Meters Single or Individual Brine Systems Three programming levels User mode Master programming Diagnostics mode Note The 3214NXT Demand Flow Network Controller is...

Страница 4: ...ONAL SAFETY BRINE VALVE Acts as a Second ary Shut Off for Timed Brine and may be used as a Primary Shut Off without Timed Brine TNT Series Typical Single Tank Installation Twin Alternating Tank Installation Available with individual brine tanks as shown or with one twin brine tank TOP VIEW Note 1 Optional stainless steel flex connectors are available for the inlet and outlet connection with each s...

Страница 5: ...actory Where ceiling heights may pose a restriction or a side mounted configuration is preferred TNT Series systems are available in this design configuration Factory pre piped and pressure tested these system designs must be shipped either skid mounted or have face piping dis assembled for shipment and re assembled at the job site Available with non corrosive polyglass composite tanks or steel Co...

Страница 6: ...ervice Rates Pressure Drop Chart 11 92 TNT 300 3 Service Rates Pressure Drop Chart 11 92 FLOW RATE G P M FLOW RATE G P M TNT 450 3 Service Rates Pressure Drop Chart 11 92 FLOW RATE G P M FLOW RATE G P M TNT 750 3 Service Rates Pressure Drop Chart 11 92 ...

Страница 7: ... epoxy resin Rustproof and corrosion resistant Operating Parameters Maximum operating pressure 150 PSI 10 2 BAR Maximum operating temperature 120ºF 49ºC Industry Approved Tanks designed and tested to meet industry standards ensuring top field performance NSF Standard 44 Warranty Allcommercial lightindustrialtanksarebackedbyanexclusivelimitedmanufacturer s warranty Sizes 24 through 48 5 year limite...

Страница 8: ...0 000 600 213 280 50 TNT Capacity Ratings 1 Steel tank design configurations available up through 60 tank diameters Consult factory for details OPERATING CONDITIONS 1 Water Pressure 30 100 psi 2 Water temperature is not to exceed 110 F and the unit cannot be subject to freezing conditions Consult factory for higher water temperature applications 3 Limit of 2 ppm of Ferrous Iron Add 3 grains per ga...