Since 1967, Hellenbrand Water Conditioners, Inc. has provided water solutions to the water treatment industry in the 

U.S. and around the world. We have developed a complete line of high quality products. An excellent example of this, 

is the Hellenbrand TNT Series Conditioners.

  TNT Series Conditioners use a flanged top-mounted or optional side-mounted adapter, three-inch NPT inlet and outlet 

solid brass control valve with a motor-driven, time-tested, hydraulically-balanced piston with a seal and spacer concept 

to pilot service flow not dependent on water pressure. No diaphragms to rupture or false transfer. It will provide up to 

170 gpm hard water by-pass during regeneration, or you may have the optional “no hard water by-pass piston” for twin 

or multiple systems. These high service flow rates, the simplified alternating and multiple lockout systems, eliminate the 

need for diaphragms, solenoids and stagers.  The five cycle TNT controller is available with either downflow (co-current) 

or upflow (counter-current) brining, with easy adjustable cycle times. The TNT Series offers you a choice of mechanical 

or microprocessor controlled meter demand systems, with two-inch or three-inch meter turbines. All systems are fac-

tory-wired and tested electrically to assure easy installation and correct operation.

Hellenbrand Means

Quality and Reliability

TNT Series Control Valve -Three Inch Inlet/Outlet

FRONT VIEW

BACK VIEW

 8.  Heavy-duty  Drive  Motor  receives  signal  from  timer 

to  efficiently  direct  water  flow  during  regeneration. 

Piston shifts smoothly and quietly regardless of water 

pressure.

 9.  Lower Heavy-duty Drive Motor receives signal from 

upper drive motor to direct the service piston into posi

-

tion. Piston shifts smoothly and quietly regardless of 

water pressure.

 10. TNT Series Timer provides fully automatic, depend

-

able timing for regeneration. The Cycle Programmer 

regulates  all  regeneration  cycles  which  are  easily 

adjustable. For manual regeneration start, simply turn 

the service indicator clockwise.

 1.  Stainless Steel Backplate will not rust or corrode.

 2.  Factory provided Drain Line Flow Control maintains 

accurate backwash rates.

 3.  Three-Inch NPT Inlet & Outlet Connections.

 4.  Solid Brass Valve assures durability and long life.

 5.  Hydraulically-balanced  Piston,  Seal,  and  Spacers. 

Lower service piston is available with or without hard 

water by-pass. Non-sticking Teflon-coated Piston al-

lows foreign particles to pass through without damaging 

the unit.

 6.  Upper Piston pilots the regeneration steps of backwash, 

brine and slow rinse, fast rinse, and brine tank refill.

 7.  Separate “Time-fill” Brining with accurate flow controls 

allows  automatic  brine  tank  refill.  Brine  Tank  Refill 

Rates  are  easily  adjustable  on  the  cycle  program-

mer. No need to worry about adjusting float valves or 

repositioning brine plugs for salt measurements.

Optional 

2” Meter Outlet

Inlet

Optional Factory Installed Vacuum 

Breaker

Controller

Inlet

Outlet

Optional Inlet & Outlet Pressure Gauges & Soft Water 

Test Port

Содержание TNT Series

Страница 1: ...Buildings Boiler Water Treatment Car Washes Commercial Buildings Condominiums Factories Hospitals Laundries Mobile Home Parks Motels and Hotels Nursing and Rest Homes Office Buildings Restaurants Schools For Commercial Industrial Applications ...

Страница 2: ...t Outlet FRONT VIEW BACK VIEW 8 Heavy duty Drive Motor receives signal from timer to efficiently direct water flow during regeneration Piston shifts smoothly and quietly regardless of water pressure 9 Lower Heavy duty Drive Motor receives signal from upper drive motor to direct the service piston into posi tion Piston shifts smoothly and quietly regardless of water pressure 10 TNT Series Timer pro...

Страница 3: ...rs between last two regenerations Hours since last regeneration Adjustable volume remaining Valve position 3200NXT Electronic Controller 3 Twin Tri Plex Four Plex Demand Recall Progressive Systems 3214NXT Controller 2 4 Units Individual Meters Single or Individual Brine Systems Three programming levels User mode Master programming Diagnostics mode Note The 3214NXT Demand Flow Network Controller is...

Страница 4: ...ONAL SAFETY BRINE VALVE Acts as a Second ary Shut Off for Timed Brine and may be used as a Primary Shut Off without Timed Brine TNT Series Typical Single Tank Installation Twin Alternating Tank Installation Available with individual brine tanks as shown or with one twin brine tank TOP VIEW Note 1 Optional stainless steel flex connectors are available for the inlet and outlet connection with each s...

Страница 5: ...actory Where ceiling heights may pose a restriction or a side mounted configuration is preferred TNT Series systems are available in this design configuration Factory pre piped and pressure tested these system designs must be shipped either skid mounted or have face piping dis assembled for shipment and re assembled at the job site Available with non corrosive polyglass composite tanks or steel Co...

Страница 6: ...ervice Rates Pressure Drop Chart 11 92 TNT 300 3 Service Rates Pressure Drop Chart 11 92 FLOW RATE G P M FLOW RATE G P M TNT 450 3 Service Rates Pressure Drop Chart 11 92 FLOW RATE G P M FLOW RATE G P M TNT 750 3 Service Rates Pressure Drop Chart 11 92 ...

Страница 7: ... epoxy resin Rustproof and corrosion resistant Operating Parameters Maximum operating pressure 150 PSI 10 2 BAR Maximum operating temperature 120ºF 49ºC Industry Approved Tanks designed and tested to meet industry standards ensuring top field performance NSF Standard 44 Warranty Allcommercial lightindustrialtanksarebackedbyanexclusivelimitedmanufacturer s warranty Sizes 24 through 48 5 year limite...

Страница 8: ...0 000 600 213 280 50 TNT Capacity Ratings 1 Steel tank design configurations available up through 60 tank diameters Consult factory for details OPERATING CONDITIONS 1 Water Pressure 30 100 psi 2 Water temperature is not to exceed 110 F and the unit cannot be subject to freezing conditions Consult factory for higher water temperature applications 3 Limit of 2 ppm of Ferrous Iron Add 3 grains per ga...