background image

Consumer’s Filter Manual

Manufactured by:

HELLENBRAND, INC.

404 Moravian Valley Road • Waunakee, Wisconsin 53597

www.hellenbrand.com • [email protected]

STORM

ProMate-6.0 Iron Curtain Storm Series

p/n 111701 Rev. B

Updated 10/30/17

© 2017

Содержание PM6 IC Storm 10

Страница 1: ...er Manual Manufactured by HELLENBRAND INC 404 Moravian Valley Road Waunakee Wisconsin 53597 www hellenbrand com info hellenbrand com STORM ProMate 6 0 Iron Curtain Storm Series p n 111701 Rev B Update...

Страница 2: ...r filter please contact the dealer who installed this system TABLE OF CONTENTS General Specifications 3 Pre Installation Check List 4 Bypass Valve Operation 4 Startup Instructions 5 Operating Conditio...

Страница 3: ...F METER Accuracy 5 Flow Rate Range 0 25 27 GPM Gallon Range 20 50 000 DIMENSIONS Drain Line 3 4 or 1 NPT Ozone Check Valve 3 8 Poly Tube ELECTRICAL CURRENT DRAW AND VOLTAGE 2 0A 120V NOTE Operating ou...

Страница 4: ...m lime and iron build up Piping that is built up heavily with lime and or iron must be replaced If piping is blocked with iron additional equipment may be needed ahead of the filter to correct the pro...

Страница 5: ...ies such as those with with positive Coliform or E Coli bacteria tests Smallamountsofhardness 0 5 2gpg mayoccurinitially when filters installed on soft water Specifications Iron Storm 10 10 x54 1 0 1...

Страница 6: ...scrolled this screen will remain constant for 5 minutes then continue to scroll The condition al screens will take precedence over the scrolling and the conditional conditions will apply OR DEALER NAM...

Страница 7: ...thium battery on circuit board provides up to 2 years of time clock backup during power outages If the power is out when battery is depleted only time of day needs to be reset all other values are sto...

Страница 8: ...valve set at NORMAL on 0 E Check control valve set up procedure regeneration time option 6 Odor bleedthrough A Test for Hydrogen Sulfide H2 S on site A Hydrogen Sulfide bleedthrough 1 Increase frequen...

Страница 9: ...110543 IC Storm 13 Tank Natural Vortech Standard with Media 5 Filter Media 110544 IC Storm 10 Rebed 110545 IC Storm 12 Rebed 110546 IC Storm 13 Rebed 6 Plate Distributor Part of Vortech Tank 7 Bypass...

Страница 10: ...uttons for 3 seconds or unplug power source jack from the printed circuit board black wire and plug back in This resets the electronics and establishes the service piston position The display should f...

Страница 11: ...hole For a filter that only backwashes injector plugs are located in both holes The nuts and caps are designed to be unscrewed or tightened by hand or with the special plastic wrench If necessary a p...

Страница 12: ...for 3 4 One DLFC must be used if 3 4 fitting is used QTY ITEM NO ORDER NO DESCRIPTION Figure 12 WATER METER AND METER PLUG 1 102141 Nut 1 QC 1 2 4 102051 Meter Assy 1 3 102687 Turbine Assy 1 4 102165...

Страница 13: ...with the special plastic wrench If necessary a pliers can be used to un screw the nut or cap Do not use a pipe wrench to tighten or loosen nuts or caps Do not place screwdriver in slots on caps and o...

Страница 14: ...ce ozone Verify ozone production prior to changing CD cell to understand need for cleaning frequency at each application Initiate regeneration attach tubing to CD cell inlet and disconnect brine elbow...

Страница 15: ...0 5 0 Max Manganese Concentration 1 0 1 0 1 0 Based upon 50 psi water pressure require different application parameters Note Manual regeneration follow sequence 2 800591 Revised 8 12 2015 FACTORY PRE...

Страница 16: ...include any labor charges This paragraph sets forth the exclusive remedy for any valid warranty claims against Hellenbrand THIS WARRANTY DOES NOT COVER defects caused by sand sediment or bacteria foul...

Отзывы: