31
HRO 6
07/26/12
ABNORMAL PERMEATE FLOW
As time progresses, the efficiency of the membrane will be reduced. In general, the salt rejection does not
change significantly until two or three years after installation when operated on properly pretreated feed
water. The permeate flow rate will begin to decline slightly after one year of operation, but can be
extended with diligent flushing and cleaning of the system. A high pH and/or precipitation of hardness
can cause premature loss in rejection.
Permeate flow should be within 20% of the rated production, after correcting the feed water temperatures
above or below 77°F. Check your permeate flow meter to determine the permeate flow rate.
NOTE:
TO DETERMINE THE TEMPERATURE CORRECTION FACTOR, LOCATE THE
TEMPERATURE CORRECTION TABLE IN THIS USER’S MANUAL AND FOLLOW THE DIRECTIONS
Содержание HRO 6 Series
Страница 2: ...2 HRO 6 07 26 12...
Страница 3: ...3 HRO 6 07 26 12 This Page Intentionally Left Blank...
Страница 10: ...10 HRO 6 07 26 12 HF5 OPTIONAL...
Страница 11: ...11 HRO 6 07 26 12 NF3 OPTIONAL...
Страница 12: ...12 HRO 6 07 26 12 NF4 OPTIONAL...
Страница 13: ...13 HRO 6 07 26 12 LC LE 4040 OPTIONAL...
Страница 14: ...14 HRO 6 07 26 12...
Страница 15: ...15 HRO 6 07 26 12 LC HR 4040 OPTIONAL...
Страница 16: ...16 HRO 6 07 26 12...
Страница 19: ...19 HRO 6 07 26 12 FIGURE 1B...
Страница 20: ...20 HRO 6 07 26 12 FIGURE 1C FIGURE 1D...
Страница 21: ...21 HRO 6 07 26 12 FIGURE 1E FIGURE 1F Note A portion of the frame has been removed to expose components...
Страница 35: ...35 HRO 6 07 26 12 DRAWINGS FIGURE 5A FIGURE 5B...
Страница 36: ...36 HRO 6 07 26 12 FIGURE 6...
Страница 37: ...37 HRO 6 07 26 12 FIGURE 7...
Страница 38: ...38 HRO 6 07 26 12 Note A portion of the frame has been removed to expose components FIGURE 8...
Страница 45: ...45 HRO 6 07 26 12 HRO 6 1800 FLOW DIAGRAM...
Страница 46: ...46 HRO 6 07 26 12 HRO 6 4000 FLOW DIAGRAM...
Страница 47: ...47 HRO 6 07 26 12 HRO 6 5000 FLOW DIAGRAM...
Страница 48: ...48 HRO 6 07 26 12 HRO 6 7000 FLOW DIAGRAM...
Страница 49: ...49 HRO 6 07 26 12 HRO 6 9000 FLOW DIAGRAM...
Страница 50: ...50 HRO 6 07 26 12 HRO 6 10 000 FLOW DIAGRAM...
Страница 51: ...51 HRO 6 07 26 12...
Страница 52: ...52 HRO 6 07 26 12...
Страница 53: ...53 HRO 6 07 26 12...
Страница 54: ...54 HRO 6 07 26 12...
Страница 55: ...55 HRO 6 07 26 12...
Страница 56: ...56 HRO 6 07 26 12...
Страница 57: ...57 HRO 6 07 26 12...
Страница 58: ...58 HRO 6 07 26 12...
Страница 59: ...59 HRO 6 07 26 12 This Page Intentionally Left Blank...