CONCENTRATE (WASTE WATER) CONNECTION 

 

Locate the 

1” or 3/4” connection (Depending on the unit)

labeled concentrate and attach to a drain. Run 

the concentrate line to an open drain in a free and unrestricted manner (no backpressure). It is advised 

that an air-break be used on the concentrate line to prevent siphoning of water from the pressure vessels 

when the system is in standby. 

 

  CAUTION: ANY RESTRICTIONS OR BLOCKAGE IN THE DRAIN LINE CAN CAUSE 

BACKPRESSURE,  WHICH  WILL  INCREASE  THE  SYSTEM’S OPERATING  PRESSURE.  THIS  CAN 

RESULT IN DAMAGE TO THE SYSTEM’S MEMBRANES AND COMPONENTS.

 

 

 

ELECTRICAL 

 

The motor used on the HRO 6-Series systems are pump and motor combination. The motor is available 

in  220/460 Volt, 50/60 Hertz,  1 Phase/3 phase.  Each  HRO 6-Series  system is equipped with a 5 foot 

electrical cord. 

 

Ensure that the electrical circuit supplying the system is compatible with the requirements of the specific 

HRO 6 model you are installing. 

 

NOTE:  IT’S

  RECOMMENDED  THAT A LICENSED ELECTRICIAN WIRE YOUR SYSTEM IN 

ACCORDANCE WITH LOCAL AND NATIONAL ELECTRICAL CODES (NEC).

 

 

  WARNING: TO REDUCE THE RISK OF ELECTRICAL SHOCK, THE INCOMING POWER 

SUPPLY MUST INCLUDE A PROTECTIVE EARTH GROUND. 

 

HRO 6-Series systems are typically controlled with a liquid level switch in a storage tank. The liquid level 

switch turns the system on when the water level in the tank drops, and off when the tank is full. Liquid 

level switches can be obtained by your local dealer or distributor. If a liquid level switch is to be used, 

install it at this time. 

 

PRE-FILTRATION 

 

HRO 6-Series systems are supplied with a 5 micron sediment filter. Change the cartridge once a month or 

when a 10-15 psi differential exists between the two pre-filter gauges. Ask your local dealer or distributor 

about Pre-Filtration systems, if required. 

 

NOTE: THE SYSTEM MUST BE OPERATED USING FILTERED FEED WATER ONLY.  

 

PUMP 

 

The pump used on the HRO 6-Series systems is of the multi-stage centrifugal stainless steel type.   

 

Follow these guidelines to ensure proper operation of the pump: 

 

  The pump must 

NEVER

 be run dry. Operating the pump without sufficient feed water will damage 

the pump. 

Содержание HRO 6 Series

Страница 1: ...HRO 6 07 26 12 Reverse Osmosis User s Manual Model HRO 6 1800 HRO 6 4000 HRO 6 5000 HRO 6 7000 HRO 6 9000 HRO 6 10 000...

Страница 2: ...2 HRO 6 07 26 12...

Страница 3: ...3 HRO 6 07 26 12 This Page Intentionally Left Blank...

Страница 4: ...HRO 6 4000 HRO 6 5000 HRO 6 7000 HRO 6 9000 HRO 6 10 000 Error Bookmark not defined SYSTEM IDENTIFICATION 17 SYSTEM PURGING 22 INITIAL START UP 23 OPERATING DO s AND DON Ts 25 OPERATION AND MAINTENAN...

Страница 5: ...DEALER OR DISTRIBUTOR FOR REVIEW NOTE PRIOR TO OPERATING OR SERVICING THE REVERSE OSMOSIS SYSTEM THIS USER S MANUAL MUST BE READ AND FULLY UNDERSTOOD KEEP THIS AND OTHER ASSOCIATED INFORMATION FOR FU...

Страница 6: ...ction on page 21 of this manual For example the HRO 6 10 000 produces 6 25 gallons per minute of permeate water at the listed operating test conditions The amount of total dissolved solids TDS rejecte...

Страница 7: ...4 2 Attach the inlet piping to the 1 FNPT Solenoid Valve feed water inlet 3 Be certain that all of the dissolved solids within the feed water are soluble at the concentrations attained in the system P...

Страница 8: ...ENDED THAT A LICENSED ELECTRICIAN WIRE YOUR SYSTEM IN ACCORDANCE WITH LOCAL AND NATIONAL ELECTRICAL CODES NEC WARNING TO REDUCE THE RISK OF ELECTRICAL SHOCK THE INCOMING POWER SUPPLY MUST INCLUDE A PR...

Страница 9: ...nform them of your system s model and pump size MOUNTING The free standing system should be bolted down in compliance with local regulation standards or securely fastened MEMBRANE ELEMENTS HRO 6 Serie...

Страница 10: ...10 HRO 6 07 26 12 HF5 OPTIONAL...

Страница 11: ...11 HRO 6 07 26 12 NF3 OPTIONAL...

Страница 12: ...12 HRO 6 07 26 12 NF4 OPTIONAL...

Страница 13: ...13 HRO 6 07 26 12 LC LE 4040 OPTIONAL...

Страница 14: ...14 HRO 6 07 26 12...

Страница 15: ...15 HRO 6 07 26 12 LC HR 4040 OPTIONAL...

Страница 16: ...16 HRO 6 07 26 12...

Страница 17: ...17 HRO 6 07 26 12 HRO 6 1800 HRO 6 4000 HRO 6 5000 HRO 6 7000 HRO 6 9000 HRO 6 10 000 SYSTEM IDENTIFICATION FIGURE 1A...

Страница 18: ...TO FEED IF APPLICABLE 9 CONCENTRATE VALVE CONTROLS FLOW OF CONCENTRATE WASTE WATER TO THE DRAIN 10 RO PUMP AND MOTOR PRESSURIZES RO SYSTEM 11 THROTTLE VALVE CONTROLS FLOW OF PUMP 12 FLOW METER MEASURE...

Страница 19: ...19 HRO 6 07 26 12 FIGURE 1B...

Страница 20: ...20 HRO 6 07 26 12 FIGURE 1C FIGURE 1D...

Страница 21: ...21 HRO 6 07 26 12 FIGURE 1E FIGURE 1F Note A portion of the frame has been removed to expose components...

Страница 22: ...open the concentrate valve Counter Clockwise Figure 1B Page 16 3 Fully close the recycle valve Clockwise If Applicable Figure 1B Page 16 4 Fully open the throttle valve Counter Clockwise Figure 1D Pa...

Страница 23: ...ure 1D Page 17 5 Turn the RO system on and adjust the concentrate waste valve recycle valve If Applicable and the throttle valve to the designed flow and pressure Figure 1B Page 16 6 Inspect the syste...

Страница 24: ...GN BASIS FOR HRO 6 1800 HRO 6 4000 HRO 6 5000 HRO 6 7000 HRO 6 9000 HRO 6 10 000 Specifications WARNING NEVER EXCEED THE SYSTEM S MAXIMUM PRESSURE RATING HRO 6 1800 HRO 6 4000 HRO 6 5000 HRO 6 7000 HR...

Страница 25: ...UL MEMBRANES AND MUST BE PREVENTED Check your feed water chemistry and pre treat the water and or reduce the system s recovery as required If necessary consult with your local dealer or distributor PR...

Страница 26: ...uts off the system when the feed water pressure drops below 15 PSI preventing damage to the pump The system restarts automatically when there is a constant pressure of 35 PSI or more PUMP THROTTLE VAL...

Страница 27: ...he O rings or brine seal if damaged 5 Flow directions should be observed for installation of each element into their respective pressure vessels REPLACING THE MEMBRANE ELEMENT WARNING THE BRINE SEAL M...

Страница 28: ...y fasten using a 5 Allen wrench 8 Reconnect any fittings that may have been disconnected when the membrane pressure vessels were disassembled 9 To Start Up the system please refer to the Initial Start...

Страница 29: ...in a solution of 2 M 100 venting the air outside of the pressure vessels Use the overflow technique circulate the M 100 solution in such a way that the remaining air in the system is minimized after...

Страница 30: ...See temperature correction sheet Low operating pressure Adjust concentrate valve POOR PERMEATE QUALITY Damage product tube o rings Inspect and or replace Damaged or oxidized membrane Replace membrane...

Страница 31: ...y after one year of operation but can be extended with diligent flushing and cleaning of the system A high pH and or precipitation of hardness can cause premature loss in rejection Permeate flow shoul...

Страница 32: ...ORS FOR MEMBRANE Find the temperature correction factor TCF from the table below Divide the rated permeate flow at 77 F by the temperature correction factor The result is the permeate flow at the desi...

Страница 33: ...ect flow Example 5 gpm 59 F 5 1 42 3 52 gpm 5 gpm 77 F 5 1 5 gpm 5 gpm 84 F 5 0 89 5 62 gpm SERVICE ASSISTANCE If service assistance is required please complete the following process Contact your loca...

Страница 34: ...system s manufacturer guarantees that the proposed product is to be free from any defects in material or workmanship when operated in accordance with written instructions for a period of one year 12...

Страница 35: ...35 HRO 6 07 26 12 DRAWINGS FIGURE 5A FIGURE 5B...

Страница 36: ...36 HRO 6 07 26 12 FIGURE 6...

Страница 37: ...37 HRO 6 07 26 12 FIGURE 7...

Страница 38: ...38 HRO 6 07 26 12 Note A portion of the frame has been removed to expose components FIGURE 8...

Страница 39: ...EDIMENT PLEATED 4 5 x 20 5 MIC 6 1 203649 HOUSING FILT BLK BLU 4 5 x 20 1 FNPT 7 1 202929 HOUSING MEM FRP 4040 P x C FNPT 8 1 204207 CONTROLLER COMPUTER C22 120 220V 1PH 9 1 200899 METER FLOW PM 1 10...

Страница 40: ...EDIMENT PLEATED 4 5 x 20 5 MIC 6 1 203649 HOUSING FILT BLK BLU 4 5 x 20 1 FNPT 7 2 202929 HOUSING MEM FRP 4040 P x C FNPT 8 1 204207 CONTROLLER COMPUTER C22 120 220V 1PH 9 1 200899 METER FLOW PM 1 10...

Страница 41: ...CART SEDIMENT PLEATED 4 5 x 20 5 MIC 6 1 203649 HOUSING FILT BLK BLU 4 5 x 20 1 FNPT 7 3 202929 HOUSING MEM FRP 4040 P x C FNPT 8 1 204207 CONTROLLER COMPUTER C22 120 220V 1PH 9 1 200899 METER FLOW P...

Страница 42: ...EDIMENT PLEATED 4 5 x 20 5 MIC 6 1 203649 HOUSING FILT BLK BLU 4 5 x 20 1 FNPT 7 4 202929 HOUSING MEM FRP 4040 P x C FNPT 8 1 204207 CONTROLLER COMPUTER C22 120 220V 1PH 9 2 200899 METER FLOW PM 1 10...

Страница 43: ...EDIMENT PLEATED 4 5 x 20 5 MIC 6 1 203649 HOUSING FILT BLK BLU 4 5 x 20 1 FNPT 7 5 202929 HOUSING MEM FRP 4040 P x C FNPT 8 1 204207 CONTROLLER COMPUTER C22 120 220V 1PH 9 2 200899 METER FLOW PM 1 10...

Страница 44: ...EDIMENT PLEATED 4 5 x 20 5 MIC 6 1 203649 HOUSING FILT BLK BLU 4 5 x 20 1 FNPT 7 6 202929 HOUSING MEM FRP 4040 P x C FNPT 8 1 204207 CONTROLLER COMPUTER C22 120 220V 1PH 9 2 200899 METER FLOW PM 1 10...

Страница 45: ...45 HRO 6 07 26 12 HRO 6 1800 FLOW DIAGRAM...

Страница 46: ...46 HRO 6 07 26 12 HRO 6 4000 FLOW DIAGRAM...

Страница 47: ...47 HRO 6 07 26 12 HRO 6 5000 FLOW DIAGRAM...

Страница 48: ...48 HRO 6 07 26 12 HRO 6 7000 FLOW DIAGRAM...

Страница 49: ...49 HRO 6 07 26 12 HRO 6 9000 FLOW DIAGRAM...

Страница 50: ...50 HRO 6 07 26 12 HRO 6 10 000 FLOW DIAGRAM...

Страница 51: ...51 HRO 6 07 26 12...

Страница 52: ...52 HRO 6 07 26 12...

Страница 53: ...53 HRO 6 07 26 12...

Страница 54: ...54 HRO 6 07 26 12...

Страница 55: ...55 HRO 6 07 26 12...

Страница 56: ...56 HRO 6 07 26 12...

Страница 57: ...57 HRO 6 07 26 12...

Страница 58: ...58 HRO 6 07 26 12...

Страница 59: ...59 HRO 6 07 26 12 This Page Intentionally Left Blank...

Отзывы: