Installation Instructions and Instructions for Use
Subject to technical modifications
–
Date of Issue March/2021
41
Installation self-supporting
Columns and rain gutters
Fig.: 3
Connect the columns (1)
with the rain gutters (2):
Push the rain gutters in the
upper profile chamber (see
Fig. 3) onto the corner joints
and fasten them with the
filister head screws M8x20
(4).
When mounting a VENTUR
SIDE, special screws
M8x20 with extremely flat
heads are used instead of
the filister head screws (4)
(see illustration).
x
2
3
2
4
4
1
3
Installation Instructions and Instructions for Use
42
Subject to technical modifications
–
Date of Issue March/2021
Installation self-supporting
Columns and rain gutters
With linkage:
Use cylinder head screws with plain washers (5) instead of filister head
screws (4). Fix the connection brackets for the rain gutters (6) with four
self-drilling head screws (7) each, distributed over the complete length.
Legend
Corner columns
Cylinder head screw M8x25
- + sealing washer M8
Rain gutters
Connection brackets for rain gutters
Corner joint
Self drilling head screw 3.9x19
Filister head screw M8x20
All filister head screws (4) for mounting the
rain gutters must be mounted bare/electrically
conductive. This applies to all rain gutters on
all column variants.
1
5
2
6
7
4
5
Installation Instructions and Instructions for Use
Subject to technical modifications
–
Date of Issue March/2021
43
Installation self-supporting
Columns and rain gutters
Place the assembled rain gutters and columns onto the floor brackets (2)
and fix them with filister head screws M8x20 (1).
1
2
5
Installation Instructions and Instructions for Use
44
Subject to technical modifications
–
Date of Issue March/2021
Installation self-supporting
Columns and rain gutters
Fig. 4
Fig. 5
Fig. 6
The 230 V mains cable
must be pulled through the
column provided for the
electrical supply up to the
upper end (see Fig. 4).
The mains cable is only
allowed to be inserted into
the column without water
drain. Please make sure
that sharp edges do not
damage the cable coating.
There is danger to life, if
defect cables or cables with
open ends are used. If you
have any doubts, gather
information from an
electrical company and let
the necessary electrical
works be carried out by a
professional electrician.
After all the socles of the
columns (3) are to be
mounted.
With columns with
integrated water drain, the
column opening at the
bottom remains open (Fig.
5).
The column openings of the
columns provided for the
electrical supply are closed
with a cover sheet (4) (for
better visual appearance,
as protection against dirt
and animals) (Fig. 6).
8
9
7
3
3
3
3