EN
MT 56
2.1.6 Safety Precautions for Hybrid/Electric Vehicles
Very high tensions occur on hybrid and electric vehicles. Due to voltage flashover on damaged
components, such as marten damage or touching live components, the risk of electric shock is
likely. High voltage at or in the vehicle can lead to death in case of inattention. Therefore observe
the following:
• Only the following qualified employees are allowed to de-energize the high-voltage system:
– High-voltage technician
– Skilled electrician for predetermined operations – Hybrid or rather electric vehicles
– Skilled electrician
• Place warning signs and warning tapes.
• Check the high-voltage system and the high-voltage lines for damage (visual inspection!).
• De-energizing the high-voltage system:
– Switch off ignition.
– Disconnect the service disconnect plug.
– Remove the fuse.
• Securing the high-voltage system against re-activation:
– Withdraw the ignition key and keep it safe.
– Keep the service disconnect plug safe or secure the battery master switch against re-
activation.
– Insulate the battery master switch, the plug connections etc. with dummy plugs, covering
caps or insulating tape with the corresponding warning notice.
• Check the de-energized state with a voltage tester. Even with disconnected high-voltage
system, residual voltage can still be present.
• Ground and short-circuit the high-voltage system (necessary only if voltage is higher than
1000 V).
• Voltage below 1000 V: Cover the parts which are close to the system or which are energized e.
g. with insulating cloth, hoses or plastic coverings. Voltage higher than 1000 V: Cover the parts
with insulating plates/protective panels specially developed for this purpose so that sufficient
protection against contact to adjacent parts is ensured.
• Regard the following before re-energizing the high-voltage system:
– All tools and utilities are removed from the hybrid/electric vehicle.
– Remove the grounding and short circuit of the high-voltage system. No cable must be
touched now.
– Attach the protective panelling that has been removed before.
– Remove the protective measures at the switching system.
28
Содержание MT 56
Страница 1: ...BD0006V0000ML0622S0 460 989 57 06 22 Operating Instructions MT 56...
Страница 2: ......
Страница 4: ...4...
Страница 22: ...DE Notizen MT 56 Notizen 22...
Страница 40: ...EN Notes MT 56 Notes 40...
Страница 57: ...FR MT 56 Notes Notes 57...
Страница 58: ...Notes MT 56 58...
Страница 76: ...IT Appunti MT 56 Appunti 76...
Страница 94: ...ES Notas MT 56 Notas 94...
Страница 112: ...NL Aantekeningen MT 56 Aantekeningen 112...
Страница 130: ...PL Notatki MT 56 Notatki 130...
Страница 148: ...DA Notater MT 56 Notater 148...
Страница 166: ...PT Notas MT 56 Notas 166...
Страница 184: ...TR Notlar MT 56 Notlar 184...
Страница 202: ...CS Pozn mky MT 56 Pozn mky 202...
Страница 220: ...HU Feljegyz sek MT 56 Feljegyz sek 220...
Страница 238: ...FI Muistiinpanot MT 56 Muistiinpanot 238...
Страница 256: ...RO Noti e MT 56 Noti e 256...
Страница 274: ...SK Pozn mky MT 56 Pozn mky 274...
Страница 276: ...EL MT 56 1 1 1 13 08 2005 276...
Страница 277: ...EL MT 56 1 2 277...
Страница 279: ...EL MT 56 2 1 3 60 V DC 42 V peak MT 56 2 1 4 Start Stop MT 56 2 1 5 MT 56 mega macs 56 279...
Страница 280: ...EL MT 56 2 1 6 Volt Volt HVT EFffT EFK Volt Volt Service Volt Service Volt Volt 1000 V 1000 V 1000 V Volt Volt 280...
Страница 282: ...EL MT 56 3 3 1 1 MT 56 1 1 1 1 1 3 1 1 1 282...
Страница 284: ...EL MT 56 3 3 1 ST3 2 T 3 Scope 1 CH1 Scope 1 CH1 4 Scope 2 CH2 Scope 2 CH2 3 4 7 MT 56 mega macs 56 MT HV MT HV 284...
Страница 285: ...EL MT 56 3 5 8 MT 56 mega macs 56 MT HV 285...
Страница 287: ...EL MT 56 MT 56 3 MT 56 MT HV 4 MT 56 MT 56 MT HV 4 3 MT 56 MT HV 287...
Страница 288: ...EL MT 56 MT 56 4 4 MT 56 MT HV mega macs X 288...