Working with the CSC-Kit Radar I
CSC-Kit Radar I
Calibrating the Radar Sensor with Magnetic Laser
3. Select the system to be calibrated under
>Basic settings<
.
A window with information and instructions appears.
CAUTION
Danger of injury or pinching through heavy parts
The angular adjustment plate may drop when fixing it to
the cross member and may cause injuries.
Ask a second person to fix the angular adjustment plate to
the cross member.
4. Attach the angular adjustment plate (1) to the cross member in
position 2.
The angular adjustment plate must be within the radar sensor area.
Depending on the selected manufacturer and vehicle type, the CSC-Kit
Radar II must be attached to the radar sensor.
5. Fix the CSC-Kit Radar II to the radar sensor (see assembly instructions
CSC-Kit Radar II) where necessary.
12