5
MultiVent
®
MV EC
Installation and Operating Instructions
5
EN
3 .2 Type plate
Example:
Fan type plate key:
Ref. no., SNR (series no.) and PC (production code) numbers clearly identify the fan.
3 .3 Accessories
The use of accessory parts, which are not recommended or offered by Helios, is not permitted. Any possible dama-
ges are not covered by the warranty. Other accessories see catalogue or www.heliosselect.de.
4 .0 Functional description
The fans are variable speed controllable by means of a 0-10 V control voltage. Suitable potentiometers (type PU/A 10),
three-step switches (type SU/A) are available in the Helios accessory range. Variable speed control is possible with a
universal control system (type EUR EC). Alternatively, the electronic differential pressure/temperature controller EDR /
ETR can be used.
m
Activation / deactivation:
EC fans can be frequently activated and deactivated via the 0-10 V control input or the release input
depending on the type . This is gentle on the electronics and ensures a long service life . Control via the
power supply (on/off) is not recommended . In general, there must be an interval of at least 120 seconds
between activation and deactivation .
m
In case of strong vibrations and/or noises, maintenance must be carried out by a specialist according to
chapter 1 .4 .
FM . . .
Flexible sleeve
Description see main catalogue
FM 125
Ref. no. 1682
FM 160
Ref. no. 1684
FM 200
Ref. no. 1670
FM 250
Ref. no. 1672
FM 315
Ref. no. 1674
MVS . . .
Protection guard
Description see main catalogue
MVS 125
Ref. no. 6072
MVS 160
Ref. no. 6074
MVS 200
Ref. no. 6075
MVS 250
Ref. no. 6076
MVS 315
Ref. no. 6077
PU/A 10
Speed potentiometer
For direct control/setpoint spe-
cification of EC fans with poten-
tiometer input.
PU 10
Ref. no. 1734
PA 10
Ref. no. 1735
SU/A-3
Three-step switch
For three-step control of EC
fans with a 0-10 V DC control
input.
SU-3 10
Ref. no. 4266
SA-3 10
Ref. no. 4267
CHAPTER 4
FUNCTION
NOTE!
ò
Manufacturer‘s address
ù
Fan marking:
CE
=
CE mark
ä
Version:
MV EC
=
Type designation
125
=
Size
ë
Ref. no.
ö
Production code / Year of constr.
ü
Rated voltage or voltage range / frequency
Å
Rated current
î
Power input
Ø
max. air flow temperature at rated operation
Æ
Protection class
Installation and operating instructions print no.
ù
ä
ë
ü
ö
Å
î
Ø
Æ
ò
Fig .3
Содержание MultiVent MV EC 125
Страница 21: ...19 MultiVent MV EC Montage und Betriebsvorschrift DE...
Страница 41: ...19 MultiVent MV EC Installation and Operating Instructions EN...
Страница 61: ...19 MultiVent MV EC Notice de montage et d utilisation FR...
Страница 62: ...20 MultiVent MV EC Notice de montage et d utilisation...
Страница 63: ...21 MultiVent MV EC Notice de montage et d utilisation...