GENERAL INFORMATIONS

Important informations

Operation:

 Important information about the ventilation system as well as settings at the

controller are specified here.

Maintenance:

 In the maintenance part important information about filter changes and necessary

cleaning and maintenance activities are specified. The user usually accomplishes maintenance

work.

Montage:

 The chapter “installation” with important installation information and unit base

settings addresses itself to professional installers. Read this instruction in any case carefully

and completely before you operate, install or connect the ventilation unit. Keep in safe

custody!

Planning documents:

 The planning office provides the necessary planning documents for the

system calculation. Additional information can be requested ex works.

Saftey instructions

For safety it is absolutely necessary that the following instructions are thoroughly read and

observed.

Receipt

The consignment contains: 

KWL EC 300 Eco with control panel

Please check delivery immediately on receipt for accuracy and damage. If damaged, please

notify carrier immediately. Delayed notification may void any possible claim.

Storage

When storing for a prolonged time the following steps are to be taken to avoid damaging

influences: protection by dry air and dustproof packing (plastic bags with drying agent and

moisture indicators). The storage area must be free of water, vibration and temperature

variations.

When storing for years or non rotation of motor an inspection of the bearings with possible

replacement and an installation inspection in accordance with VDE 0530 are necessary

before starting using the unit. Damage caused by incorrect storage, transportation or

installation are not valid warranty claims.

Operation – Use

Compact unit to use in dry indoor areas for ventilation with heat recovery. Suitable as central

or decentral solution for commercial or industrial applications. The standard equipment

permits the installation and use in frost-protected rooms up to +5 °C.

For operation under difficult conditions, e.g. high humidity, long periods of standstill, high

air pollution or through climatic, technical or electronic influences other than standard

operations may not be suitable. For this reason please enquire and obtain operation release.

A release by a third party is not valid.

Mode of action

In the heat exchanger the cold outside air and the warm extracted air "crosses over" without

touching. Through this exchange the energy of the warm air (>90 %) is tranfered to the

incoming air. Additionally a thermostat controlled heating element (pre-heating) warms up

the inlet air (in extreme cold weather conditions) to the required temperature. The inlet air

is directed to the living rooms and bedrooms through ducting and valves. The used air is

extracted from the bathrooms, toilets and kitchens. It flows back to the fan via the ducting

systems, transfering heat before being released into the open air.

Performance

To achieve the given performance, the unit must be correctly installed. Varying from the

design and/or installation requireements and also by incorrect operation can lead to a

reduction in the unit capacity. Noise figures are stated in sound power levels LWA in dB(A)

(conforms to DIN 44635 T.1). Sound pressure levels LPA depend on room specific conditions.

These conditions may affect the measured result on site and vary from the catalogue data.

Installation – Assembly

 

The KWL EC 300 Eco is suitable for „hanging“ arrangement for installation in a cupboard

or for installation on a wall and therfore for installation within the room of the dewelling.

There are drilled holes for wall installation at the level of the air connecions. For wall

installation a support plate to hang the unit on is included. If a wall installation is not possible,

the unit can also be fixed through its side panell into the ajoining surface.

3

m

 Important

ß

Содержание KWL EC 300 Eco R

Страница 1: ...MONTAGE UND BETRIEBSANLEITUNG Modelle KWL EC 300 Eco R KWL EC 300 Eco L mit 4 Stufenschalter F r die kontrollierte L ftung mit W rmer ckgewinnung...

Страница 2: ...EC 300 Eco Seite 9 LEISTUNGSWERTE Ventilatorleistungen Seite 10 KWL EC 300 Eco Messpunkte Seite 10 Schallwerte Seite 10 ELEKTROANSCHL SSE Anschlussplan Seite 11 WARTUNG Filter und Kreuz Gegenstromtau...

Страница 3: ...ggregat f r den Einsatz in trockener Innenumgebung zur Be und Entl ftung mit W rmer ckgewinnung Geeignet als Zentralger t oder als dezentrale L sung im gewerblichen und industriellen Bereich Die serie...

Страница 4: ...WL w hrend der Brenndauer ausgeschaltet Dabei muss sichergestellt werden dass durch den Betrieb der Wohnungsl ftungsanlage kein gr erer Unterdruck als 4 Pa in der Wohneinheit erzeugt wird Das Zentrall...

Страница 5: ...innung Filter Ger t KWL EC 300 Eco M glichkeiten der Luftleistungsregelung ber Zusatzausstattungen Zuluft Abluft Gewicht IP 34 Zuluft 97 W DC Abluft 97 W DC Kreuz Gegenstromtauscher Sommer Winterbetri...

Страница 6: ...nate vermieden werden Wenn die Fortlufttemperatur unter den voreingestellten Grenzwert sinkt schaltet die Entfros terautomatik den Zuluftventilator vor bergehend ab Das Ger t KWL EC 300 Eco kann ber d...

Страница 7: ...satbildung an kalten Rohren und Geh useteilen Anschlussstutzen Das Ger t ist mit vier Anschlussstutzen Durchmesser 125 mit Gummilippendichtungen ausger stet Die Luftkan le werden fest und dicht in die...

Страница 8: ...ngsger t gelangen Im Reinigungsfall ist der Kugel Syphon leicht zu ffnen und wieder zu befestigen WICHTIG Der Rohrverlauf der Kanalisation darf hinter dem Siphon nicht ansteigen Der Kondensatablauf is...

Страница 9: ...der Montage des Ger tes Druckmessstutzen und Druck messschl uche in den Anschlussstutzen so anzubringen das eine einwandfreie Druckmessung vorgenommen werden kann Bypassfunktion Die Einstellung erfolg...

Страница 10: ...esamt f r beide Ventilatoren 1 2 3 4 5 36 W 72 W 130 W 160 W 194 W LEISTUNGSWERTE 10 Messpunkte nach dem Durchlasskragen Die Ventilatorkennlinien zeigen den verf gbaren Gesamtdruck f r den Druckverlus...

Страница 11: ...ter berwachung siehe Install Beispiel in MBV ohne Uhr bzw Party Schalter vom 4 Stufenschalter Klemme direkt auf Steuerklemme im Klemmkasten anschlie en b L1 N PE Optional Bauseitiger On off switch Tre...

Страница 12: ...dem Einbau darauf achten dass im Kreuz Gegenstromtauscher kei ne Feuchtigkeit zur ckbleibt Zum Einbau den Tauscher anheben und gleichzeitig ein schieben und nach unten auf die Dichtungen aufsetzen Di...

Страница 13: ...len die nicht von Helios empfohlen oder angeboten werden ist nicht statthaft Eventuell auftretende Sch den unterliegen nicht der Gew hrleistung Die Verwendung eines elektronischen oder transformatoris...

Страница 14: ...ht und keine Anzeige leuchte T rschalter ist eventuell defekt oder T r ist nicht richtig geschlossen Keine Netzspannung Sicherung evtl durchge brannt T rschalter und Sicherungen berpr fen Ger t hat ei...

Страница 15: ...INSTALLATION AND OPERATING INSTRUCTIONS Model KWL EC 300 Eco R KWL EC 300 Eco L with 4 level operation switch Controlled ventilation system with heat recovery...

Страница 16: ...L EC 300 Eco page 9 PERFORMANCE Fan performance page 10 KWL EC 300 Eco measuring points page 10 Sound pressure level page 10 ELECTRICAL CONNECTIONS Wiring page 11 MAINTENANCE Filter and heat recovery...

Страница 17: ...le as central or decentral solution for commercial or industrial applications The standard equipment permits the installation and use in frost protected rooms up to 5 C For operation under difficult c...

Страница 18: ...0100 DIN57100 T 420 VDE0721 DIN18379 Before maintenace an isolator is required for with a minimum of 3 mm contact opening of each pole Electrical connection should only be carried out by a qualified...

Страница 19: ...it KWL EC 300 Eco Control Accessory optional Zuluft Abluft Gewicht IP 34 Supply air 97 W DC Extract air 97 W DC Counter flow cell Summer winter automation manual G4 F7 supply air filter accessory opti...

Страница 20: ...ting of the heat recovery cells intermittently stops the supply air fan when the temperature of exhaust air goes under the set threshold value The unit KWL EC 300 Eco has an 4 level operation switch a...

Страница 21: ...it attach to the mounting plate The unit is splash protected IP34 and can thus also be mounted in a damp room NOTE Remove the transportation lock wingnut in the extract duct Before start up check the...

Страница 22: ...t into the ventilation unit In the case of cleaning the ball siphon is easy to open and to fasten again IMPORTANT The drainage may not rise after the siphon The condensate water outlet is placed in th...

Страница 23: ...l bypass flap Open or closed manually The outside air is passed by the counter flow heat exchanger at 100 and thus the heat recovery is stopped Defrost function of heat recovery cell To protect the he...

Страница 24: ...h fans 1 2 3 4 5 36 W 72 W 130 W 160 W 194 W PERFORMANCE 10 Measuring points after the spigots The performance curves indicate the available total pressure for the pressure loss in the duct system KWL...

Страница 25: ...iehe MBV Montage und Betriebsvorschrift Optional Bauseits bei Raumluft abh ngigen Feuerst tten zu erstellen 3 x 1 5mm N L1 Filterwechselanzeige Bauseits zur erstellen Wert variiert je nach Type z B 20...

Страница 26: ...inside of the cross counter heat exchanger before installation If the cell is contaminated soak it in a solution of water and washing up liquid Rinse the cell clean with a jet of water When all the w...

Страница 27: ...ent Grills must be cleaned each year from leafs or other objects by in coming air Accessories The use of accessories not recommended or provided by HELIOS is not permitted Damage arising from such usa...

Страница 28: ...d none of the indicator lamps of the control panel is lit The door switch may be broken or has not closed properly The socket is dead the fuse may have burned out for instance Check the door switch an...

Страница 29: ...NOTICE DE MONTAGE ET D UTILISATION Mod les KWL EC 300 Eco R KWL EC 300 Eco L avec un commutateur 4 tages Groupe double flux avec r cup ration d nergie...

Страница 30: ...e 7 Raccordement des conduits page 7 Ecoulement des condensats page 7 Raccordements lectriques KWL EC 300 Eco page 7 Montage commutateur 4 vitesses page 7 Pressostat diff rentiel DDS page 7 Evacuation...

Страница 31: ...oteur pendant plusieurs ann es il faut proc der avant la remise en route un contr le des roulements en les rempla ant ventuellement De plus il est n cessaire d effectuer un contr le lectrique selon le...

Страница 32: ...on par ex sonde de temp rature avec raccordement lectrique sur la centrale Par ailleurs il faut s assurer que lors du fonctionnement de l installation de ventilation la d pression dans la pi ce ne d p...

Страница 33: ...it de r gulation Accessoires Air neuf Air repris Poids IP 34 Air neuf 97 W DC Air extrait 97 W DC Echangeur contre courant Estival hiver op ration bypass manuel G4 F7 optional G4 41 kg Manuelle par co...

Страница 34: ...hermique EWT Lorsque la temp rature de l air extrait descend sous un seuil d fini une sonde de protection antigel coupe momentan ment le ventilateur de soufflage Le groupe KWL EC 300 Eco peut tre r gu...

Страница 35: ...a raulique Raccordements lectriques du KWL EC 300 Eco Les raccordements lectriques en 230 VAC 50Kz doivent tre effectu s par une personne autoris e Pr voir un dispositif de coupure du courant multipol...

Страница 36: ...au d vacuation ne peuvent pas remonter dans la centrale en d pression m me en cas de fonctionnement sec De plus il peut tre d mont facilement pour le nettoyage et l entretien IMPORTANT Le r seau d vac...

Страница 37: ...le pressostat DDS Branchement voir sch ma SS 857 Le pressostat contr le la pression statique de l installation la perte de charge des filtres et de d bit d air du ventilateur de soufflage L allumage...

Страница 38: ...ventilation Puissance absorb e totale pour les deux ventilateurs 1 2 3 4 5 36 W 72 W 130 W 160 W 194 W Les mesures ont t relev es dans les raccords Les courbes de fonctionnement indiquent la pression...

Страница 39: ...ontage und Betriebsvorschrift Optional Bauseits bei Raumluft abh ngigen Feuerst tten zu erstellen 3 x 1 5mm N L1 Filterwechselanzeige Bauseits zur erstellen Wert variiert je nach Type z B 200 ECO 1 3...

Страница 40: ...ec un jet d eau faible pression V rifier que l changeur soit sec avant de le remonter dans l appareil Pour le remontage poser l changeur sur le rail central inf rieur puis le pousser au fond du caisso...

Страница 41: ...ommande L utilisation d accessoires non agr es par Helios est d conseill les dommages ventuels ne seraient pas couverts par la garantie constructeur L utilisation d un variateur de vitesse lectronique...

Страница 42: ...t mal ferm e Pas de tension v rifier le fusible V rifier l interrupteur de s curit de la porte et les fusibles Le fusible de protection de la carte est une cartouche de calibre T800 mA Eventuellement...

Отзывы: