Soffit element installation package –
KWL 45-160 LE-RP
Installation and Operating Instructions
7
5. Then seal the ring gap against diffusion (see Fig. 9).
m
Danger to life due to electric shock!
Before any installation work, disconnect the connection cable from the mains power supply and secure
against unintentional restart!
6. Lay connection cable correctly in the empty conduit.
The connection cable must protrude from the empty conduit in the wall installation sleeve with an overhang
of min . 300 mm!
7. Detach the plastic bar from the wall installation sleeve to insert the connection cable and cut out the wall installation
sleeve cut-out (see Fig. 10).
8. Insert into the wall installation sleeve to protect against structural protection cover contamination on the internal and
external side of the wall.
Installation step EXTERNAL SIDE OF WALL:
1. Remove structural protection cover on external side of wall.
2. Mount seal to wall installation sleeve on external side of wall (see Fig.11).
3. Shorten soffit channel to the corresponding length.
Take soffit channel installation requirements into account!
Fig .8
INTERNAL SIDE OF WALL
Ring gap
Installation
foam
Fig .9
INTERNAL SIDE OF WALL
Sealing
compound
m
DANGER
Fig .10
INTERNAL SIDE OF WALL
Cut out the
connection cable
cut-out
Fig .11
EXTERNAL SIDE OF WALL
Seal
EN