10
Charge the battery.
3. Battery - Recharging,Replacement
3.1 Safety Regulations for Handling Acid Batteries
3.1.1 Fire protection
Do not smoke and avoid naked flames when handling batteries. Wherever an industrial truck
is parked for charging there shall be no inflammable material or lubricants capable of creating
sparks within 2 metres around the truck. The room must be ventilated. Fire protection equipment
must be on hand.
The use of unsuitable fire-protection equipment can result in acid burns In the event of fire a
reaction with the battery acid can occur if water used to extinguish the fire. This can lead to acid
burns.
Use powder extinguishers.
Never extinguish burning batteries with water.
3.1.2 Battery maintenance
The batteries must be kept dry and clean. Terminals and cable shoes must be clean, lightly
greased with terminal grease and must be securely tightened.
3.2 Battery and charger Types
Battery
Charger
Voltage
24 V
Input
AC 220V
50/60Hz
Capacity
345 Ah
Output
DC 24V/50A
3.3 Charging
Do not full charge the battery, it will damage the battery.
The battery needs to be charged within 24 hours after used out.
3.3.1 Charging
Switch OFF
Open the battery hood panel
Connect the cable with the battery and charger
Switch on charger to charge
3.3.2 Finish of charging
Switch off the charger
Содержание 14-850