34
m. Detection of flammable refrigerants
Under no circumstances shall potential sources of ignition be used in the searching for or
detection of refrigerant leaks. A halide torch (or any other detector using a naked flame)
shall not be used.
n. Leak detection methods
The following leak detection methods are deemed acceptable for systems containing
flammable refrigerants. Electronic leak detectors shall be used to detect flammable
refrigerants, but the sensitivity may not be adequate, or may need re-calibration. (Detection
equipment shall be calibrated in a refrigerant-free area.) Ensure that the detector is not a
potential source of ignition and is suitable for the refrigerant used. Leak detection
equipment shall be set at a percentage of the LFL of the refrigerant and shall be calibrated
to the refrigerant employed and the appropriate percentage of gas (25 % maximum) is
confirmed. Leak detection fluids are suitable for use with most refrigerants but the use of
detergents containing chlorine shall be avoided as the chlorine may react with the
refrigerant and corrode the copper pipe-work. If a leak is suspected, all naked flames shall
be removed/ extinguished.
If a leakage of refrigerant is found which requires brazing, all of the refrigerant shall be
recovered from the system, or isolated (by means of shut off valves) in a part of the system
remote from the leak.
Oxygen free nitrogen (OFN) shall then be purged through the system both before and during
the brazing process.
o. Removal and evacuation
When breaking into the refrigerant circuit to make repairs or for any other purpose
conventional procedures shall be used. However, it is important that best practice is
followed since flammability is a consideration. The following procedure shall be adhered to:
Remove refrigerant; Purge the circuit with inert gas; Evacuate; Purge again with inert gas;
Open the circuit by cutting or brazing.
The refrigerant charge shall be recovered into the correct recovery cylinders. The system
shall be flushed with OFN to render the unit safe. This process may need to be repeated
several times. Compressed air or oxygen shall not be used for this task. Flushing shall be
achieved by breaking the vacuum in the system with OFN and continuing to fill until the
working pressure is achieved, then venting to atmosphere, and finally pulling down to a
vacuum. This process shall be repeated until no refrigerant is within the system. When the
final OFN charge is used, the system shall be vented down to atmospheric pressure to
enable work to take place. This operation is absolutely vital if brazing operations on the
pipe-work are to take place. Ensure that the outlet for the vacuum pump is not close to any
ignition sources and there is ventilation available.
p. Charging procedures
In addition to conventional charging procedures, the following requirements shall be
followed. Ensure that contamination of different refrigerants does not occur when using
charging equipment. Hoses or lines shall be as short as possible to minimise the amount of
refrigerant contained in them. Cylinders shall be kept upright.
Содержание HDU-M20
Страница 52: ...www heinner com 51 HDU M20 www heinner com 20 L...
Страница 53: ...www heinner com 52 I II...
Страница 54: ...www heinner com 53 III 1 2 3 4 5 6 7 8 9 10 11 12...
Страница 55: ...www heinner com 54 1 2 3 4 5 6 7 8 9 10 11 12 T3 15A 250V 350V...
Страница 56: ...www heinner com 55 IV R32 R290 4...
Страница 57: ...www heinner com 56 R32 R290 1 2 3 4 5 6 a...
Страница 58: ...www heinner com 57...
Страница 59: ...www heinner com 58 1 2...
Страница 60: ...www heinner com 59 25 o...
Страница 61: ...www heinner com 60 80...
Страница 62: ...www heinner com 61 t...
Страница 63: ...www heinner com 62 V...
Страница 64: ...www heinner com 63...
Страница 65: ...www heinner com 64 VI 20 5 C 41 F 5 C 41 F 40 20 20 20 40...
Страница 66: ...www heinner com 65 24 5 C 35 C...
Страница 67: ...www heinner com 66 5 CONT 0 5 10 1 24 5 0 0 P2 35 85 5 0 24...
Страница 68: ...www heinner com 67 40 50 60 TURBO 30 3 3...
Страница 69: ...www heinner com 68 VII 1 8 P2 30 8 P2 2...
Страница 70: ...www heinner com 69 1 2 3...
Страница 71: ...www heinner com 70...
Страница 72: ...www heinner com 71 1 2 3 30 A B A B VIII A B...
Страница 73: ...www heinner com 72 A B C C A B B C...
Страница 74: ...www heinner com 73 A B A B...
Страница 75: ...www heinner com 74 5 C 41 F ES AS P1 P2 IX...