July 02
Machine Parameters
TNC 370 D
4–57
4.4 Positioning
Machine
parameter
Function and input
Change via
Reaction
MP1010.0-3 Rapid
traverse
Input:
80 to 300 000 [mm/min]
PLC
MP1020.0-3
Manual feed rate
Input:
80 to 300 000 [mm/min]
PLC
MP1030.0-3 Positioning
window
Input:
0. 001 to 2.000 [mm]
PLC
MP1040
Polarity of the nominal value voltage for the
positive traverse direction
Input: %xxxx
Bit
0 to 3
0 = not active
Axis
X to 4
1 = active
Reset
MP1050.0-3
Analog voltage for rapid traverse
Input:
1.000 to 9.000 [V]
PLC
MP1060.0-3 Acceleration
Input:
0.001 to 20.000 [m/s
2
]
PLC
MP1070.0
Radial acceleration
Input:
0.001 to 20.000 [m/s
2
]
PLC
RUN
MP1070.1
Acceleration at contour transition elements
Input:
0.001 to 20.000 [m/s
2
]
PLC
RUN
MP1080.0-3 Integral
factor
Input:
0 to 65 535
PLC
RUN
MP1090
Jerk limiting on the contour
Input:
0 to 1000 [m/s³]
0 = no jerk limiting (MP 1520 active)
1 to 1000 jerk limiting
MP1097.0-3
Axis-specific jerk limit
(active only with M112 and MP7415.1 bit 2)
Input:
1 to 1000 [m/s
3
]
Recommended input value 10 to 50
MP1099
Filter order for nominal position value filter
Input: 0 to 7
0 = no filter
1 to 7 filter order
Recommended input value 1 to 3
MP1110.0-3 Standstill
monitoring
Input:
0.001 to 30.000 [mm]
PLC
MP1140.0-3
Movement monitor on
Input:
0.030 to 10.000 [V]
PLC
RUN
Содержание TNC 370 D
Страница 1: ... z ad snnn Technical Information NC Software 286 02x xx ...
Страница 44: ...3 9 Mounting Dimensions LE 370 D July 02 Mounting and Electrical Installation TNC 370 D 3 41 ...
Страница 48: ...July 02 Mounting and Electrical Installation TNC 370 D 3 45 3 11 Grounding plan ...
Страница 49: ...3 46 TNC 370 D Mounting and Electrical Installation July 02 ...