The following wiring plan is suggested for shielding in the terminal box :
Insulated against housing
Leads are provided
with en sleeves.
Cable screens are led onto 0.14 mm
2
insulated strands via crimp eyelets.
SERVO
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
LE
•
•
X
Y
Z
S
IV
Insulated against housing
Leads are provided with end sleeves
Cable shields are led onto 0.14 mm² insulated
wires via crimp eyelets.
Connection
terminal
Assignment
1
Nominal value output
X axis
2
Nominal value output 0 V
X axis
3
Nominal value output
Y axis
4
Nominal value output 0 V
Y axis
5
Nominal value output
Z axis
6
Nominal value output 0 V
Z axis
7
Nominal value output
IV axis
8
Nominal value output 0 V
IV axis
9
Not used
10
Not used
11
Nominal value output
S axis
12
Nominal value output 0 V
S axis
13 Shield
connection
14 Shield
connection
15 Shield
connection
16 Shield
connection
3–16
TNC 370 D
Mounting and Electrical Installation