7
7
I
J
K
L
M
N
O
Cable
Entry
Fixing
Point
Fixing
Point
Bracket Bracket Bracket Outlet
2.5l
59
96
50
342
52.5
169
152
5.0l
61
117
67
401
84
217
163
7.5l
61
117
67
401
84
217
225
3.0 INSTALLATION - WATER SUPPLY
3.1 Select appropriate push fit connector for chosen entry position:
Bottom entry water - 15mm x 15mm 90º elbow.
Rear entry water - 15mm x 15mm straight.
Note: stainless or chromed pipes DO NOT provide secure connections with
push fit fittings (use copper pipe at joints).
3.2 Push the connector fully home (28mm engagement) onto the solenoid valve
inlet spigot. To remove a push fit connector the collar (collet) should be
pushed towards the body of the fitting whilst pulling the connector off the
pipe.
3.3 If the inlet pipe run is horizontal and beneath the unit ensure it does not
prevent access to the case screws.
3.4 Connect the inlet pipe to the push fit connector ensuring it is fully pushed
home (28mm engagement). After connection DO NOT make soldered joints
in the pipe work close to the heater, as the heat may damage the connector
or the water heater itself.
3.5 A WRAS listed isolating valve should be fitted to the cold supply to facilitate
servicing the heater.
3.6 Push fit connectors are supplied to allow either bottom or rear entry of
services.
4.0 INSTALLATION - VENT PIPE
4.1 Select appropriate push fit connector for chosen entry position:
Bottom entry vent - 15mm x 15mm straight
Rear entry vent - 15mm x 15mm 90º elbow
4.2 Push the connector fully home (28mm engagement) onto the vent pipe
connection.
4.3 Connect the vent pipe to the push fit connector ensuring it is pushed fully
home (28mm engagement). Refer to the vent pipe requirement detailed in
IMPORTANT INSTALLATION POINTS. If a bottom entry vent pipe is used the
pipe must terminate below the unit, in a safe visible position. After connection
DO NOT make soldered joints in the pipe work close to the heater as the
heat may damage the connector or the water heater itself.