background image

4

1.0 IMPORTANT INSTALLATION POINTS

1.1  The Heatstore Ultima Profile Eco stores and dispenses water at or close to 

boiling point at all times it is switched on. Due caution must be taken when 

choosing a location for the product to minimise misuse. Locate the unit over 

a draining board NOT over the sink or basin.

1.2  Push fit connectors DO NOT grip chromed or stainless pipe.

1.3  The Heatstore Ultima Profile Eco is a vented water heater. The vent pipe 

must never be blocked or obstructed, it must be a minimum of 15mm outside 

diameter pipe. Where the vent pipe length exceeds 3m the pipe diameter 

should be increased. The vent pipe must be laid to a continuous fall and 

discharge in a safe and visible position; it must discharge via a tundish or 

finish a minimum of 20mm above a draining board. The vent pipe material 

must be capable of conveying boiling water.  The vent pipe must never be 

connected directly to a soil pipe.

1.4  Wherever  possible  the  Heatstore  Ultima  Profile  Eco  should  be  supplied 

directly from a rising main. If fed from a cold water feed cistern, the cistern 

must comply with the Water Regulations Guide (clause R27.2). It should be 

noted that water quality may be reduced when supplied from a cistern and 

additional forms of water pretreatment may be necessary.

1.5  In hard water areas, heated water will produce lime scale which will be 

deposited within the heater. If this is not regularly removed it will impair the 

operation of the heater. Where rapid and excessive scale build up is likely 

to occur the use of a proprietary scale reducing device may be beneficial.

1.6  The  installation  must  be  carried  out  in  accordance  with  the  relevant 

requirements of:      

The appropriate Building Regulations either The Building Regulations 

• 

(England  &  Wales),  The  Building  Regulations  (Scotland)  or  Building 

Regulations (Northern Ireland). 

The Water Supply (Water Fittings) Regulations in England & Wales or 

• 

Water Byelaws in Scotland.

1.7  The Heatstore Ultima Profile Eco will adjust for ambient (room) temperatures 

of between 1°C and 40°C.

1.8  When not in use care must be taken to prevent it freezing; if thought to be 

frozen it must not be switched on. It must be left to thaw and must then be 

thoroughly inspected to ensure it is totally thawed and undamaged.

1.9  The unit is not suitable for installation in an area where a water jet could be 

used.

Содержание Ultima Profile Eco 2.5

Страница 1: ... Instructions Models 2 5 5 0 7 5 litre Please read and understand these instructions before starting work Please leave this leaflet with the user following installation WARNING This Boiling Water Heater must only be installed by qualified persons ...

Страница 2: ...ions left with them for future reference This appliance is not intended for use by persons including children with reduced physical sensory or mental capabilities or lack of experience and knowledge unless they have been given supervision or instruction concerning the use of the appliance by a person responsible for their safety Children should be supervised to ensure that they do not play with th...

Страница 3: ...trical rating 2 3 2 5kW 230 240V Weight full Model 2 5 litre 8 4kg Model 5 0 litre 11 8kg Model 7 5 litre 15 4kg Rated pressure Minimum supply pressure 0 05MPa 0 5 bar Maximum supply pressure 1 0MPa 10 bar Enclosure rated IP X2 Nominal commissioning times minutes to temperature ready Model 2 5 litre 16 Model 5 0 litre 24 Model 7 5 litre 32 STANDARDS AND APPROVALS Complies with the requirement of E...

Страница 4: ... cistern must comply with the Water Regulations Guide clause R27 2 It should be noted that water quality may be reduced when supplied from a cistern and additional forms of water pretreatment may be necessary 1 5 In hard water areas heated water will produce lime scale which will be deposited within the heater If this is not regularly removed it will impair the operation of the heater Where rapid ...

Страница 5: ... reduce the efficiency of the unit 2 4 Ensure that the wall can support the full weight of the unit see technical specifications p3 and that there are no hidden services electricity gas or water below the surface of the wall 2 5 Using the backplate mark the fixing positions and water and vent entry points Drill and plug the fixing positions Fix the mounting bracket to the wall using the two No 12 ...

Страница 6: ...ure 01 Dimensions H J I L M N Fixing Bracket Fixing Hole K O Model DIMENSIONS mm A B C D E F G H Inlet Vent Inlet Vent Inlet Vent Cable Entry 2 5l 445 290 190 85 115 101 49 46 5 0l 510 335 200 103 133 101 49 69 7 5l 510 335 262 103 133 101 49 69 ...

Страница 7: ... ensuring it is fully pushed home 28mm engagement After connection DO NOT make soldered joints in the pipe work close to the heater as the heat may damage the connector or the water heater itself 3 5 A WRAS listed isolating valve should be fitted to the cold supply to facilitate servicing the heater 3 6 Push fit connectors are supplied to allow either bottom or rear entry of services 4 0 INSTALLAT...

Страница 8: ...unit is to be unused for significant periods of time running costs can be reduced by switching the unit off It is recommended that this is done automatically by incorporating a suitable timeswitch in the supply to the unit NOTE A timeswitch must be capable of switching 13 Amps resistive load ELEMENT A L L N S PRIMARY CUTOUT A SOLENOID VALVE LOWER SENSOR EARTH UPPER SENSOR EARTH UPPER LEVEL SENSOR ...

Страница 9: ...ing too low If this occurs switch the electrical supply OFF for several seconds and then switch ON The calibration sequence will reset Wait for the READY indicator to remain illuminated 6 6 The unit is now ready to use however it is recommended that the first few fills be drawn off and discarded to ensure the freshness of the water 6 7 The tap sealing washer pressure has been already set If the ta...

Страница 10: ... storage tank 7 3 The front cover and spout will require a periodic wipe to clean any marks splashes from use 8 0 FAULT FINDING Your Heatstore Ultima Profile Eco should give trouble free operation However should a fault occur the table below should allow most faults to be identified Fault finding should only be carried out by a competent person SYMPTOM POSSIBLE CAUSE ACTION No indicator lights 1 I...

Страница 11: ...uild up 1 Check continuity 5Kohms at 100 C 2 Check connections to electronic control Replace if necessary 3 Descale unit Drips from outlet 1 Incorrect spring tension 2 Scale debris under tap seal 3 Damaged tap seal 4 Scale on tap outlet spout 1 Ensure tap headwork nut correctly adjusted 2 Remove and clean as necessary 3 Replace tap seal 4 Clean tap outlet Water runs on when tap released 1 Scale on...

Страница 12: ...del 95 614 131 Cover assy screws 5 0ltr Model 95 614 132 Cover assy screws 7 5ltr Model 95 614 134 12 Steam condenser assy 2 5ltr Model 95 607 015 Steam condenser assy 5 0ltr Model 95 607 016 Steam condenser assy 7 5ltr Model 95 607 018 13 Condenser sealing gasket 2 5ltr Model 95 611 817 Condenser sealing gasket 5 0ltr Model 95 611 819 Condenser sealing gasket 7 5ltr Model 95 611 820 14 O ring kit...

Страница 13: ...13 13 17 7 8 9 10 14 16 15 21 14 2 1 22 12 11 13 6 5 4 23 13 3 Figure 03 Spares ...

Страница 14: ... draw water off When the green neon is on and stays as a solid light the unit is ready to be used 10 5 If the store of hot water is completely withdrawn the flow rate from the outlet tap will reduce to the filling rate of the heater leave for 2 minutes before drawing any more water off This slow flow rate allows the incoming water to be instantly reheated it does not indicate a fault with the wate...

Страница 15: ...y maintained as detailed in the Installation and User Instructions 4 The appliance has been used only for heating potable water 5 The appliance has been installed in the UK The appliance is not guaranteed against damage by frost and the inner container with integral heating element is not guaranteed against excessive scale build up This guarantee in no way affects the statutory rights of the consu...

Страница 16: ...a Road Avonmouth Bristol BS11 9DB www heatstore co uk 36006143_issue_01 Waste electrical products should not be disposed of with household waste Please recycle where facilities exist Check with your local authority or retailer for recycling advice X2 ...

Отзывы: