Installation Engineer Note:
The most likely reason for no heated water is an open circuit thermal fuse.
See label on front insulation for details.
This can be caused at initial commissioning if the heating element is energized with no
water in the tank.
Alternatively, it may be due to a back siphonage in the cold water supply caused by a
break or disconnection.
If you feel that your installation may suffer from a water failure, we recommend the
fitting of a non-return water check valve.