Water Connection (s

ee Diagram 4 for suggested installation plan) 

 

Oversink 

(see Diagram 3)

 

When using the tap and spout as supplied, the cold water connection is made directly to 

the Ø15mm compression fitting at the rear of the cold inlet tap.  
Ensure that the water flow is in line with the flow direction arrow moulded on the cold 

inlet tap. 

 

Undersink 

If the unit is to be mounted below sink level, it MUST be connected to special open 

outlet taps as recommended by Heatstore. 
The economic performance of the heater will be enhanced by lagging the hot water pipe 

from the heater to the outlet. 

 

Oversink and Undersink Installation 

Before final assembly of the tap the appropriate restrictor insert must be selected and 

fitted into the end of the cold inlet pipe on the heater (see Table A). 
The correct insert will ensure that the flow rate of water through the heater is at an 

optimum to prevent undue mixing of the incoming cold water with the stored hot water, 
as well as avoiding any unnecessary pressure within the tank. 

 
 

 
 

 

 

 
 

 
 

 

 

 

Suggested Installation Plan 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

Содержание HS65VT-Eco

Страница 1: ...orage water heater for use with Heatstore recommended fittings for one outlet only It operates on the displacement principle i e when cold water is admitted into the bottom of the tank hot water flows out through the outlet Installation We recommend that this unit should be installed in the following order 1 Fit wall bracket 2 Fit mains electrical cable to the unit 3 Fit heater to the wall 4 Conne...

Страница 2: ...any unit that is to be filled from the heater Electrical Connection The installation must be in accordance with the current BS7671 IEE Wiring Regulations and Part P of the Building Regulations WARNING THE UNIT MUST BE FILLED WITH WATER BEFORE POWER IS SWITCHED ON 1 The heater is suitable for 240 230V single phase A C supply 2 The live brown and neutral blue wires must be connected to the designate...

Страница 3: ...ecial open outlet taps as recommended by Heatstore The economic performance of the heater will be enhanced by lagging the hot water pipe from the heater to the outlet Oversink and Undersink Installation Before final assembly of the tap the appropriate restrictor insert must be selected and fitted into the end of the cold inlet pipe on the heater see Table A The correct insert will ensure that the ...

Страница 4: ...h the bezel keeping the front cover square to the wall 3 Once the mechanical programmer is engaged into the bezel adjust the position so that it is a snug fit over the appliance Backplate 4 Replace the top fixing screws x2 then press the cover at the base while tightening the bottom fixing screws x2 5 Check that the mechanical programmer is free to spin and the switch is in its aperture 6 The appl...

Страница 5: ...ent time and day Rotate the dial slowly in the clockwise direction until the correct time and day segment on the dial is approaching the arrowhead shown at the top of the dial Note the dial is printed with the 24 hour clock 6 00 am 6 on the dial and 6 00 pm 18 on the dial Programming switching times see Diagram 6 Set the tappets between the desired ON and OFF period required ALL the tappets must b...

Страница 6: ...er first establishing that the temperature is as required the knob may be removed and the blanking grommet supplied free with heater inserted in the hole This grommet is a relatively loose fit and can be made more secure by the use of suitable silicone sealant or PTFE tape etc not supplied Draining the Tank If it is required to drain the tank this can be effected by undoing the screw in the base p...

Страница 7: ...or disconnection If you feel that your installation may suffer from a water failure we recommend the fitting of a non return water check valve After Sales Service We offer a technical advisory service on the telephone to contractors and other customers with problems in the field Ring 0117 923 5375 E Mail enquiries heatstore adivision co uk Remember to quote the exact type of unit as written on the...

Страница 8: ...l details of terms and conditions are available on request MANUFACTURED FOR VICTORIA ROAD AVONMOUTH BRISTOL BS11 9DB TEL 0117 923 5375 FAX 0117 923 5374 Website www heatstore co uk A4 Leaflet No 578 2018 11a ...