5
Usage
The
Heatstore HS65VT-Eco
contains an integrated weekly mechanical programmer.
This facility allows the user to set the heater “ON” and “OFF” periods for each separate
day of the week.
“ON” periods are settable by sliding the timer segments to the outer position.
The minimum selectable “ON” period is 2 hours and 20 minutes.
A major benefit of the
Heatstore HS65VT-Eco
heater is the energy saving possibilities of
controllability and the facility in a commercial installation to set a programme to cover a
weekly usage pattern including weekends.
However, the thick insulation contained in the
Heatstore HS65VT-Eco
heater also
ensures economic running costs if the heater is left on at all times.
Setting up the weekly mechanical programmer
The dial should be set to the current time and day.
Rotate the dial slowly in the clockwise direction, until the correct time and day segment
on the dial is approaching the arrowhead shown at the top of the dial.
Note the dial is printed with the 24 hour clock.
6.00 am = 6 on the dial and 6.00 pm = 18 on the dial.
Programming switching times
(see Diagram 6)
Set the tappets between the desired “ON” and “OFF” period
required.
ALL the tappets must be pushed to the outer edge of the dial for
an extended “ON” period.
Each tappet switches the output for a 2 hour and 20 minute
period.
Setting the selector switch
(see Diagram 7)
“
” setting.
The heater will operate and heat water as programmed.
The separate water temperature thermostat will control the water
temperature.
“ ” setting.
The weekly programmer is over-ridden.
The water heater is “OFF” and the water will not be heated.
“ ” setting.
The weekly programmer is over-ridden.
The water heater is “ON” and the separate water temperature
thermostat will control the water storage temperature.