Installation Instructions and Owner’s Manual

Unvented Liquid Propane Fired Room Heater

 Figure 10

2.  Mark screws locations on wall.
3.  Remove heater from mounting bracket.
4.  If installing bottom mounting screw into hollow 

or solid wall, install wall anchors. Follow steps 1 

through 4 under Attaching to Wall using Anchor. 

If installing bottom mounting screw into wall 

stud, drill holes at marked locations using 9/64” 

drill bit.

5.  Re-place heater onto mounting bracket.
6.  Place spacers between bottom mounting holes 

and wall anchor or drilled hole.

7.  Hold spacer in place with one hand. With the 

other hand, insert mounting screw through 

bottom mounting hole and spacer. Place tip of 

screw in opening of wall anchor or drilled hole.

8.  Tighten both screws until heater is firmly se

-

cured to wall. Do not over tighten.

Note: Do not re-place front panel at this time. 

Replace front panel after making gas connections 

and checking for leaks.

FLOOR MOUNTING AWAY FROM WALL:

Installing Support Feet (See figure 11.)

1.  Lay heater onto table on its back with bottom 

edge overhanging table edge.

2.  Securely attach feet to bottom of heater using 

2 – self-tapping screws each.

Figure 11

Note: Feet should have long end going out the 

front of heater, and the edge coinciding with side of 

heater. If feet overhang side of the heater, switch 

leg location.
3.  Place heater on non-combustible surface (see 

Locating Heater, page 6) before proceeding 

with gas connection. If this will be a permanent 

location, heater may be locked into position 

using anchoring holes in mounting feet.

Note: Use of floor mounting feet will require 

you to use a 3/8 NPT street elbow to make gas 

connection.

CONNECTING TO GAS SUPPLY

WARNING:

 A qualified service person must connect 

heater to gas supply. Follow all local codes. 

WARNING:

 This appliance requires a 3/8” NPT 

(National Pipe Thread) inlet connection to the 

pressure regulator. Use of floor mounting feet will 

require you to use a 3/8 NPT street elbow to make 

gas connection. 

CAUTION: Never connect heater directly to the 

Propane supply. This heater requires an external 

regulator (not supplied). Install the external regulator 

between the heater and Propane/LP supply. 
The installer must supply an external regulator. 

The external regulator will reduce the incoming gas 

pressure to between 11 and 14 inches of water. If 

you do not reduce incoming gas pressure heater 

regulator damage could occur. Install external 

regulator with the vent pointing down. Pointing the 

vent down protects it from freezing rain or sleet.

CAUTION:

 Use only new black iron or steel pipe. 

Internally-tinned copper tubing may be used in certain 

areas. Check your local codes. Use pipe of large 

enough diameter to allow proper gas volume to heater. 

If pipe is too small, undue loss of pressure will occur. 

Installation must include an equipment shutoff valve, 

union and plugged 1/8” NPT tap. Locate NPT tap within 

reach of test gauge hookup. NPT tap must be upstream 

from heater (see figure 12).
*A CSA/AGA certified equipment shutoff valve with 

1/8” NPT tap is an acceptable alternative to test gauge 

connection. Purchase the CSA/AGA certified equipment 

shutoff valve from your dealer. 

IMPORTANT:

 Install an equipment shutoff valve in an 

accessible location. The equipment shutoff valve is for 

turning on or shutting off the gas to the appliance.
Apply pipe joint sealant lightly to male threads. This will 

prevent excess sealant from going into pipe. Excess 

sealant in pipe could result in clogged heater fuel train.

CAUTION:

 Use pipe joint sealant that is resistant to 

LP-Gas

Install sediment trap in supply line as shown in figure 

12. Locate sediment trap where it is within reach 

for cleaning. A sediment trap traps moisture and 

contaminants. This keeps them from going into heater. 

If sediment trap is not installed or is installed improperly, 

heater may not run correctly.

IMPORTANT:

 Hold pressure regulator with wrench 

when connecting it to gas piping and/or fittings.

Screw  

hole

Screw  

hole

Содержание HSVFBF10LP

Страница 1: ...r from a neighbor s phone Follow the gas supplier s instructions If you cannot reach your gas supplier call the fire department Installation and service must be performed by a qualified installer service agency or the gas supplier WARNING This is an unvented gas fired heater It uses air oxygen from the room in which it is installed Provisions for adequate combustion and ventilation air must be pro...

Страница 2: ...liance Due to high temperatures heater should be kept out of traffic and away from furniture and draperies Surface of heater becomes very hot when running Keep children and adults away from hot surfaces to avoid burns or clothing ignition Heater will remain hot for a time after shutdown Allow heater surfaces to cool before handling Young children should be carefully supervised when they are in the...

Страница 3: ...you provide fresh outside air If heater keeps shutting off it requires servicing 5 Turn off and let cool before servicing Only a qualified service person should service and repair heater 6 Do not run heater Where flammable liquids or vapors are used or stored During dusty conditions 7 Before using furniture polish wax carpet cleaner or similar products turn heater off If heated the vapors from the...

Страница 4: ...nstruction provide adequate combustion and ventilation air by the methods described in the National Fuel Gas Code NFPA 54 ANSI Z223 1 Section 5 3 or applicable local codes 3 Add the Btu hr of all the fuel burning appliances in the space such as Vent free heater Gas water SAFETY DEVICE This heater has a pilot with an Oxygen Depletion Sensor ODS safety shut off system The ODS pilot shuts off the hea...

Страница 5: ...ecause the actual Btu hr used is more than the maximum Btu hr the space can support You must provide additional fresh air Your options are as follows A Rework worksheet and the space of an adjoining room If the extra space provides an unconfined space remove door to adjoining room or add ventilation grills between the rooms See Ventilation Air From Inside Building Fig 2 B Vent room directly to the...

Страница 6: ...t be at least 18 inches above floor Locate heater where moving vehicle will not hit it CAUTION This heater creates warm air currents These currents move heat to wall surfaces next to heater Installing heater next to vinyl or cloth wall covering or operating heater where impurities such as tobacco smoke aromatic candles cleaning fluids oil or kerosene lamps etc are present in the air may discolor w...

Страница 7: ... mounting bracket is firmly fastened to wall studs Attaching to Wall using Anchor For attaching mounting bracket to hollow walls wall areas between studs or solid walls concrete or masonry Note Wall anchors mounting screws and spacer are in hardware package The hardware package is provided with heater 1 Drill holes at marked locations using 5 16 drill bit For solid walls concrete or masonry drill ...

Страница 8: ...r Use of floor mounting feet will require you to use a 3 8 NPT street elbow to make gas connection CAUTION Never connect heater directly to the Propane supply This heater requires an external regulator not supplied Install the external regulator between the heater and Propane LP supply The installer must supply an external regulator The external regulator will reduce the incoming gas pressure to b...

Страница 9: ...Reconnect heater and equipment shutoff valve to gas supply 8 Reconnected fittings must be checked for leaks in next section Low Pressure Test Pressure Equal To or Less Than psig 3 5 kPa 1 Close equipment shutoff valve see figure 13 2 Pressurize supply piping system by either using compressed air or opening propane LP supply valve 3 Check all joints from the propane LP supply valve to equipment shu...

Страница 10: ...ushed in slightly Do not force 4 Wait five 5 minutes to clear out any gas Then smell for gas including near the floor If you smell gas STOP Follow B in the safety information above If you do not smell gas go to the next step 5 Push in gas control know slightly and turn counterclockwise to PILOT IGN and depress for five 5 seconds Note The first time that the heater is operated after connecting the ...

Страница 11: ...rille guard is in place before running heater If screen or grille guard is removed for servicing it must be replaced prior to operating the heater WARNING Failure to keep the primary air opening s of the burner s clean may result in sooting and property damage CLEANING ODS PILOT AND BURNER Use as vacuum cleaner pressurized air or small soft bristled brush to clean CLEANING BURNER PILOT AIR HOLE IN...

Страница 12: ... thermocouple 7 Replace Control valve Burner does not light after ODS pilot is lit 1 Burner orifice is clogged 2 Burner orifice diameter to small 3 Inlet gas pressure is too low 1 Clean burner orifice see Cleaning and Maintenance on page 11 or replace burner orifice 2 Replace burner orifice 3 Contact local gas company Delayed ignition of burner 1 Manifold pressure is too low 2 Burner orifice is cl...

Страница 13: ...ing Gas Connections page 9 2 Replace control valve Gas odor during combustion 1 Foreign matter between control valve and burner 2 Gas leak See WARNING statement at top of page 1 Take apart gas tubing and remove foreign matter 2 Locate and correct all leaks see Checking Gas Connections page 9 Heater produces a clicking ticking noise just after burner is lit or shut off 1 Metal expanding while heati...

Страница 14: ...ner Left Bracket 1 18 N A Heat Shield 1 7 N A ODS Pilot Assembly w Thermocouple LP 1 19 N A Back Heat Shield 1 8 80017 Burner Assembly 1 20 80005 Valve Bracket 1 9 80009 Orifice 1 21 80006 Knob 1 10 N A Burner Right Bracket 1 22 80080 Valve 1 11 80016 Elbow Adapter 90 Regulator Connection 1 23 80034 Glass Bracket 1 12 80078 Regulator 1 70342 Hardware Kit not shown 1 1 2 3 4 5 6 7 8 9 10 11 12 13 1...

Страница 15: ...056 ODS Pilot Assembly w Thermocouple LP 1 15 N A Heat Shield 1 6 N A ODS Bottom Bracket 1 16 N A Back Heat Shield 1 7 N A Fireproof Plate 1 17 80005 Valve Bracket 1 8 70597 3 8 FTP x 3 8 MPT Elbow 1 18 80006 Knob 1 9 80078 Regulator 1 19 80080 Valve 1 10 N A Regulator Mounting Bracket 1 70342 Hardware Kit not shown 1 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 PARTS LIST AND DIAGRAM WARNING F...

Страница 16: ...aterial and workmanship for a period of five years from the date of manufacture During the first two years EGI will repair or replace this product if it is proven to be defective within the first two years and it is returned at customer expense with proof of purchase to the location of EGI s choice EGI will be the sole judge of what is determined to be a defect In year s three to five EGI will pro...

Отзывы: