HeatStar HSVFBF10LP Скачать руководство пользователя страница 11

11

Installation Instructions and Owner’s Manual

Unvented Liquid Propane Fired Room Heater

IMPORTANT:

 Release downward pressure while 

turning control knob. Control knob must be locked at 

the desired position.

TO TURN OFF GAS TO APPLIANCE

SHUTTING OFF HEATER:

1.  Turn off equipment shutoff valve. 
2.  Turn control knob clockwise

 to the OFF 

position.

SHUTTING OFF BURNER ONLY (PILOT STAYS LIT)

1.  Turn control knob clockwise

 to the 

PILOT/IGN position.

INSPECTING BURNER

Check pilot flame pattern and burner flame pattern 

often.

PILOT FLAME PATTERN

Figure 17 show a correct pilot flame pattern and also 

shows an incorrect pilot flame pattern. The incorrect 

pilot flame pattern is not touching thermocouple. 

This will cause the thermocouple to cool. When the 

thermocouple cools, the heater will shut down. If pilot 

flame pattern is incorrect, as shown in Figure 17:

• 

Turn heater off (see 

To Turn OFF Gas to 

Appliance

, page 10.

 

• 

See Troubleshooting, pages 12-13.

CLEANING AND MAINTENANCE

WARNING:

 Turn off heater and let cool before 

servicing. 

For maintenance of the inside cabinet or to access 

the burner and pilot assembly for cleaning or service. 

Remove the four screws(two located on each side) that 

secure the front shell to the unit.(Figure 6) Gently lift 

up on the front shell to disengage the hooks and pull 

forward to remove it. You will now be able to access all 

of the internal components of the appliance.

CAUTION:

 You must keep control areas, burner and 

circulation air passageways of heater clean. Inspect 

these areas of heater before use. Have the heater 

inspected yearly by a qualified service person. Heater 

may need more frequent cleaning due to excess lent 

from carpeting, bedding material, pet hair, etc. 
Make sure grille guard is in place before running 

heater. If screen or grille guard is removed for servicing 

it must be replaced prior to operating the heater. 

WARNING:

 Failure to keep the primary air 

opening(s) of the burner(s) clean may result in 

sooting and property damage. 

CLEANING ODS/PILOT AND BURNER

• 

Use as vacuum cleaner, pressurized air or 

small soft bristled brush to clean.

CLEANING BURNER PILOT AIR HOLE INLET

We recommend that you clean the unit every 2,500 

hours of operation or every three months. We also 

recommend that you keep the burner tube and pilot 

assembly clean and free of dust and dirt. To clean these 

parts we recommend using compressed air no greater 

than 30 psig.
This can be done by using a vacuum cleaner in the 

blow position, using compressed air in a can, please 

follow the directions on the can. If you don’t follow 

directions on the can you could damage the burner or 

pilot assembly. In addition, the directions that follow 

should also be followed.

1.  Shut off the unit, including the pilot. Allow the 

unit to cool for at least thirty minutes.

2.  Inspect burner and pilot for dust and dirt.
3.  Blow air through the port/slots and holes in the 

burner.

A yellow tip on the pilot flame indicates dust and dirt in 

the pilot assembly. To clean the pilot assembly find the 

small pilot air inlet hole about two inches from where 

the pilot flame comes out of the pilot assembly (see 

figure 18). With the unit off, lightly blow air through the 

air inlet hole. You may blow through a drinking straw if 

compressed air is not available.

CLEANING HEATER CABINET

Air passageways

• 

Use a vacuum cleaner or pressurized air to 

clean

Exterior

• 

Use a soft cloth dampened with a mild soap 

and water mixture. Wipe the cabinet to remove 

dust.ion air and create odors and possible 

discoloration of walls and ceilings.

Pilot Air Inlet Hole

Pilot Assembly

Figure 17

Correct pilot position.

Incorrect pilot position.

Figure 18

Содержание HSVFBF10LP

Страница 1: ...r from a neighbor s phone Follow the gas supplier s instructions If you cannot reach your gas supplier call the fire department Installation and service must be performed by a qualified installer service agency or the gas supplier WARNING This is an unvented gas fired heater It uses air oxygen from the room in which it is installed Provisions for adequate combustion and ventilation air must be pro...

Страница 2: ...liance Due to high temperatures heater should be kept out of traffic and away from furniture and draperies Surface of heater becomes very hot when running Keep children and adults away from hot surfaces to avoid burns or clothing ignition Heater will remain hot for a time after shutdown Allow heater surfaces to cool before handling Young children should be carefully supervised when they are in the...

Страница 3: ...you provide fresh outside air If heater keeps shutting off it requires servicing 5 Turn off and let cool before servicing Only a qualified service person should service and repair heater 6 Do not run heater Where flammable liquids or vapors are used or stored During dusty conditions 7 Before using furniture polish wax carpet cleaner or similar products turn heater off If heated the vapors from the...

Страница 4: ...nstruction provide adequate combustion and ventilation air by the methods described in the National Fuel Gas Code NFPA 54 ANSI Z223 1 Section 5 3 or applicable local codes 3 Add the Btu hr of all the fuel burning appliances in the space such as Vent free heater Gas water SAFETY DEVICE This heater has a pilot with an Oxygen Depletion Sensor ODS safety shut off system The ODS pilot shuts off the hea...

Страница 5: ...ecause the actual Btu hr used is more than the maximum Btu hr the space can support You must provide additional fresh air Your options are as follows A Rework worksheet and the space of an adjoining room If the extra space provides an unconfined space remove door to adjoining room or add ventilation grills between the rooms See Ventilation Air From Inside Building Fig 2 B Vent room directly to the...

Страница 6: ...t be at least 18 inches above floor Locate heater where moving vehicle will not hit it CAUTION This heater creates warm air currents These currents move heat to wall surfaces next to heater Installing heater next to vinyl or cloth wall covering or operating heater where impurities such as tobacco smoke aromatic candles cleaning fluids oil or kerosene lamps etc are present in the air may discolor w...

Страница 7: ... mounting bracket is firmly fastened to wall studs Attaching to Wall using Anchor For attaching mounting bracket to hollow walls wall areas between studs or solid walls concrete or masonry Note Wall anchors mounting screws and spacer are in hardware package The hardware package is provided with heater 1 Drill holes at marked locations using 5 16 drill bit For solid walls concrete or masonry drill ...

Страница 8: ...r Use of floor mounting feet will require you to use a 3 8 NPT street elbow to make gas connection CAUTION Never connect heater directly to the Propane supply This heater requires an external regulator not supplied Install the external regulator between the heater and Propane LP supply The installer must supply an external regulator The external regulator will reduce the incoming gas pressure to b...

Страница 9: ...Reconnect heater and equipment shutoff valve to gas supply 8 Reconnected fittings must be checked for leaks in next section Low Pressure Test Pressure Equal To or Less Than psig 3 5 kPa 1 Close equipment shutoff valve see figure 13 2 Pressurize supply piping system by either using compressed air or opening propane LP supply valve 3 Check all joints from the propane LP supply valve to equipment shu...

Страница 10: ...ushed in slightly Do not force 4 Wait five 5 minutes to clear out any gas Then smell for gas including near the floor If you smell gas STOP Follow B in the safety information above If you do not smell gas go to the next step 5 Push in gas control know slightly and turn counterclockwise to PILOT IGN and depress for five 5 seconds Note The first time that the heater is operated after connecting the ...

Страница 11: ...rille guard is in place before running heater If screen or grille guard is removed for servicing it must be replaced prior to operating the heater WARNING Failure to keep the primary air opening s of the burner s clean may result in sooting and property damage CLEANING ODS PILOT AND BURNER Use as vacuum cleaner pressurized air or small soft bristled brush to clean CLEANING BURNER PILOT AIR HOLE IN...

Страница 12: ... thermocouple 7 Replace Control valve Burner does not light after ODS pilot is lit 1 Burner orifice is clogged 2 Burner orifice diameter to small 3 Inlet gas pressure is too low 1 Clean burner orifice see Cleaning and Maintenance on page 11 or replace burner orifice 2 Replace burner orifice 3 Contact local gas company Delayed ignition of burner 1 Manifold pressure is too low 2 Burner orifice is cl...

Страница 13: ...ing Gas Connections page 9 2 Replace control valve Gas odor during combustion 1 Foreign matter between control valve and burner 2 Gas leak See WARNING statement at top of page 1 Take apart gas tubing and remove foreign matter 2 Locate and correct all leaks see Checking Gas Connections page 9 Heater produces a clicking ticking noise just after burner is lit or shut off 1 Metal expanding while heati...

Страница 14: ...ner Left Bracket 1 18 N A Heat Shield 1 7 N A ODS Pilot Assembly w Thermocouple LP 1 19 N A Back Heat Shield 1 8 80017 Burner Assembly 1 20 80005 Valve Bracket 1 9 80009 Orifice 1 21 80006 Knob 1 10 N A Burner Right Bracket 1 22 80080 Valve 1 11 80016 Elbow Adapter 90 Regulator Connection 1 23 80034 Glass Bracket 1 12 80078 Regulator 1 70342 Hardware Kit not shown 1 1 2 3 4 5 6 7 8 9 10 11 12 13 1...

Страница 15: ...056 ODS Pilot Assembly w Thermocouple LP 1 15 N A Heat Shield 1 6 N A ODS Bottom Bracket 1 16 N A Back Heat Shield 1 7 N A Fireproof Plate 1 17 80005 Valve Bracket 1 8 70597 3 8 FTP x 3 8 MPT Elbow 1 18 80006 Knob 1 9 80078 Regulator 1 19 80080 Valve 1 10 N A Regulator Mounting Bracket 1 70342 Hardware Kit not shown 1 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 PARTS LIST AND DIAGRAM WARNING F...

Страница 16: ...aterial and workmanship for a period of five years from the date of manufacture During the first two years EGI will repair or replace this product if it is proven to be defective within the first two years and it is returned at customer expense with proof of purchase to the location of EGI s choice EGI will be the sole judge of what is determined to be a defect In year s three to five EGI will pro...