Operating Instructions and Owner’s Manual

Where can the heater be installed?

The enerRadiant HST heater is intended for installation in the
following areas:

 Residential applications, such as:

 garages

 greenhouses

 workshops

 Light industrial/commercial applications, such as:

 entranceways

 lobby areas

 Lunch rooms

 aircraft hangars (see Section 2 for restrictions)

 public garages ( see Section 2 for restrictions)

Where can’t the heater be installed?

The enerRadiant HST heater is not intended for installation in the
following areas:

Residential living or sleeping areas

Basements

Installer’s responsibility

The enerRadiant HST heater, as well as the gas and electrical
supply, and the venting of the heater must be installed in
accordance with applicable specifications and codes. Only firms (or
individuals) well qualified in this type of work should install the
system. Consult local Building Inspectors, Fire Marshals or your
local Enerco Independent Representative for guidance.

Use the information given in this manual together with the cited
codes and regulations to perform the installation. If any aspects of
the installation are unclear, consult your Enerco Independent
Representative for clarification. The installer must furnish all needed
materials that are not furnished as standard equipment. It is also
the installer’s responsibility to see that the materials and
installation methods used, result in a job that is workmanlike in
appearance and is in compliance with all applicable codes and
requirements to this manual. The installer must give this manual to
the owner.

Section 2 PLANNING

General

This section provides the following information:

Defines the gas, electric and venting requirements for the

enerRadiant HST heater.

Specifies the national standards and applicable codes that

apply to the gas, electric and venting requirements.

Specifies the national standards and applicable codes that

apply to non-residential installations.

Gas Service Requirements:
System Requirements

Inlet Connection

Connection: ½” Male NPT

Inlet Pressure

Natural Gas:

Minimum - Inlet 5.0” w.c.

Maximum – Inlet 10.5” w.c.

LP Gas (propane):

Minimum – Inlet 10.5” w.c.

Maximum – Inlet 14.0” w.c.

Manifold Pressure

Natural Gas:  4.0” w.c.

LP Gas (propane): 10.0” w.c.

Type of Gas

The type of gas appearing on the nameplate must be the type of
gas used. Installation must comply with local codes and
recommendations of the local gas company. United States: Refer to
National Fuel Gas Code, ANSI Z223.1 – latest revision, (same as
NFPA Bulletin 54). Canada: Refer to Can 1-B149.1: Installation
Codes for Gas Burning Appliances.

Gas Supply Lines

The size of the gas supply lines must comply with local codes and
recommendations of the local gas company. United States: Refer to
National Fuel Gas Code, ANSI Z223.1 – latest revision, (same as
NFPA Bulletin 54). Canada: Refer to CAN 1-B149.1: Installation
Codes for Gas Burning Appliances.

A 1/8” NPT plugged tap must be installed in the gas line
connection immediately upstream of the heater that is farthest
from the gas supply meter. The tap is required for checking system
gas pressure.

Meter and Service

Meter and service must be large enough to handle all the heaters
being installed plus any other connected load. The gas line which
feeds the system must be large enough to supply the required gas
with a maximum pressure drop of ½” w.c. When gas piping is not
included in the layout drawing, the local gas supplier will usually
help in planning the gas piping.

Содержание enerradiant HST35

Страница 1: ...Installation and service must be performed by a qualified installer service agency or the gas supplier If you cannot reach your gas supplier call the Fire Department Gas Fired Low Intensity Infrared H...

Страница 2: ...pour se conformer aux precautions et aux instructions a fourni avec cet appareil de chauffage avoir pour resultat la mort blessure et la perte de propriete ou les dommages physiques serieuses du dang...

Страница 3: ...ST 45 Kit includes 06050 4 Formed Grille 1 End Grilles Installation Kit 02834 1 1 x 24 Long Stainless Flex Hose 2 1 NPT Ball Shut Off Valve 3 1 NPT Pipe Tee 4 1 x 4 Long Nipple 5 1 NPT Pipe Cap Vent K...

Страница 4: ...y downward to the space to be heated Heat Exchanger A U shaped tube through which the heated products of combustion pass Rear Movable Hanger Provides support for the heat exchanger and reflector at th...

Страница 5: ...NS Electrical Rating 120VAC 60Hz single phase 1 amp Connection 3 pin moulded plug Gas Inlet Connection Connection Male NPT Gas Inlet Pressure The minimum inlet gas supply pressure for the purpose of i...

Страница 6: ...is section provides the following information Defines the gas electric and venting requirements for the enerRadiant HST heater Specifies the national standards and applicable codes that apply to the g...

Страница 7: ...the floor Minimum required safe distances to combustibles must be maintained from vehicles parked below the heater When installed over hoists the minimum required safe distances to combustible must be...

Страница 8: ...as required Choose Location for Heater When selecting a suitable mounting location for the enerRadiant HST heater it is important to consider the following 1 The heater must meet the minimum mounting...

Страница 9: ...3 5kPa WARNING Materials and items when stored under this heater will be subjected to radiant heat and could be seriously damaged 4 All horizontal venting sections must slope away from the heater at...

Страница 10: ...ed through the roof be sure to carefully review the roof option installa tion portion of this section Ensure that the selected mounting site will satisfy the measurement param eters vent length not to...

Страница 11: ...ets The tube ends extend through the flanges to help with alignment 3 Using the four long and four short nuts from the bolt kit 02876 secure the tube set to the burner box As shown in the diagram use...

Страница 12: ...1 Natural Gas and Propane Installation Code 2 In accordance with the current ANSI Z223 1 NFPA 54 National Fuel Gas Code A vent shall not terminate directly above a sidewalk or paved driveway that is l...

Страница 13: ...of the National Fuel Gas Code or the authority having jurisdiction In regions of the country where prevailing winds are consistently higher than 40 mph it may be necessary to terminate the vent system...

Страница 14: ...to be constructed of galvanized sheet metal or other approved noncombustible corrosion resistant material as indicated by state and or local codes 2 For horizontal venting the vent lengths may be as f...

Страница 15: ...flue is a problem the flue length should be shortened or insulated g For vent specifications all of the following conditions must be met The maximum equivalent length of vent pipe should be carefully...

Страница 16: ...ded below the heater for each 1 000 Btu hr of heater input When outside air is used the opening below the heater shall be one square inch of free area for each 4 000 Btu hr of heater input In contamin...

Страница 17: ...lectrical Code ANSI NFPA 70 or Canadian Electrical Code CSA 22 1 if an external electrical source is utilized Gas Service Installation Install Gas Supply Lines A gas supply connection is required as s...

Страница 18: ...burrs 3 Use LP resistant joint compound on all threads 4 Check the pipe and tube connections for leaks before placing heating equipment into service When checking for gas leaks use a soap and water so...

Страница 19: ...hen occur 8 Periodic visual check of burner flame while unit is in operation through sight glass in bottom of unit Section 6 MAINTENANCE Pre Season Maintenance Heater area to be kept clear and free fo...

Страница 20: ...h does not operate Igniter spark gap incorrect Try This Unplug heater power cord from the electrical outlet wait for a minimum of five seconds Plug heater cord back into outlet Unplug heater power cor...

Страница 21: ...essure requirements contact the gas company Check for 24V across valve terminals Check Shutoff On Valve IF NO Check wiring between the ignition module and the valve Repair replace wires as required If...

Страница 22: ...keyed to the associated parts list I B A C J F H G D E ITEM PART NUMBER DESCRIPTION HST 35 HST 45 A 02808 Spark Electrode 1 1 B 02837 Ignition Wire 1 1 C 05735 Orifice HST35 NG 1 05795 Orifice HST 45...

Страница 23: ...er Box for F108847 F102850 HST 45NG Burner Box for F108850 F102851 HST 45LP Burner Box for F108851 B F106000 HST 35 Tube Set Short F106250 HST45 Tube Set Long C 06014 Hanger D 06016 Hanger Clamp E 060...

Страница 24: ...lso supply us with the purchase date and the name and address of the dealer from whom you purchased our product The foregoing is the full extent of the responsibility of the Company There are no other...

Отзывы: