background image

10

Enerco | enerRadiant® HST Series Heater

Operating Instructions and Owner’s Manual

Hang the Heater

Residential garages come in a variety of sizes, shapes, styles and
methods of construction. Because of all these variables, it is not
possible to include mounting hardware with the enerRadiant HST
heater. Although wooden rafters and joists are the most common
overhead structural members in residential garage applications,
other structural configurations are also illustrated below.

In the typical suspension methods shown below, lengths of chain
are shown as a means of lowering the heater. However, for most
residential applications it may not be necessary to lower the heater.
Instead, it may be possible to screw hook-type hardware into the
underside of a beam. The exposed hook could directly engage one
of the two mounting holes in the front fixed hanger, while another
hook could engage in one of the three suspension loops of the
rear movable hanger.

Whichever method of suspension is selected, the two required

suspension points must be capable of supporting a minimum
of 150 pounds each.

Heater Orientation

The enerRadiant HST heater may be installed in any of the three
orientations indicated below. Select the heater orientation that is

best suited for the location that you have chosen for your heater.

 Horizontally

 Tilted 45° Right

 Tilted 45°° Left

 NOTE:

 If the heater is going to be vented through the roof,

be sure to carefully review the roof option installa-
tion portion of this section. Ensure that the selected
mounting site will satisfy the measurement param-
eters (vent length not to exceed 25 feet) described in
that section. Horizontal Installation

Horizontal Installation

1. Using S-hooks, attach two equal lengths of 2/0 chain, or

equivalent, to the two uppermost holes in the front fixed
hanger.

2. Slip the free end of both chains onto another S-hook, as shown.

3. The uppermost S-hook can now be installed on the suspension

hardware that you have installed for suspension of the unit. An
additional length of chain may also now be installed, if required,
to lower the heater.

 NOTE: 

The hook portion of hook-type suspension hardware

may directly engage the two holes in the front fixed
hanger and the center loop of the rear moveable
hanger.

45° Tilted Installation

1. Determine if the heater is going to be tilted left, or tilted right.

The front and rear suspension points selected must be on the
same side (left or right) of the heater as shown below.

2. Attach suspension hooks and/or chains to the selected

suspension points of the heater.

Wood Beam

Threaded Hook

Most common for
residential
applications

Locknut

Washer

Wood Beam

Washer

Screw Hook

min. 3/8" (10 mm)

I-Beam

Beam Clamp

As Req'd

S-Hook

Bar Joist Clip

Truss

Concrete Beam

Anchor

Most common for non-residential applications

Front Fixed Hanger

Rear Movable Hanger

Use these two suspension
points for 

Tilted 45

°

Right 

Installation

Tilted Right

Use these two suspension points for

Tilted 45

°

 Lef t

 Installation

Tilted Left

Содержание enerradiant HST35

Страница 1: ...Installation and service must be performed by a qualified installer service agency or the gas supplier If you cannot reach your gas supplier call the Fire Department Gas Fired Low Intensity Infrared H...

Страница 2: ...pour se conformer aux precautions et aux instructions a fourni avec cet appareil de chauffage avoir pour resultat la mort blessure et la perte de propriete ou les dommages physiques serieuses du dang...

Страница 3: ...ST 45 Kit includes 06050 4 Formed Grille 1 End Grilles Installation Kit 02834 1 1 x 24 Long Stainless Flex Hose 2 1 NPT Ball Shut Off Valve 3 1 NPT Pipe Tee 4 1 x 4 Long Nipple 5 1 NPT Pipe Cap Vent K...

Страница 4: ...y downward to the space to be heated Heat Exchanger A U shaped tube through which the heated products of combustion pass Rear Movable Hanger Provides support for the heat exchanger and reflector at th...

Страница 5: ...NS Electrical Rating 120VAC 60Hz single phase 1 amp Connection 3 pin moulded plug Gas Inlet Connection Connection Male NPT Gas Inlet Pressure The minimum inlet gas supply pressure for the purpose of i...

Страница 6: ...is section provides the following information Defines the gas electric and venting requirements for the enerRadiant HST heater Specifies the national standards and applicable codes that apply to the g...

Страница 7: ...the floor Minimum required safe distances to combustibles must be maintained from vehicles parked below the heater When installed over hoists the minimum required safe distances to combustible must be...

Страница 8: ...as required Choose Location for Heater When selecting a suitable mounting location for the enerRadiant HST heater it is important to consider the following 1 The heater must meet the minimum mounting...

Страница 9: ...3 5kPa WARNING Materials and items when stored under this heater will be subjected to radiant heat and could be seriously damaged 4 All horizontal venting sections must slope away from the heater at...

Страница 10: ...ed through the roof be sure to carefully review the roof option installa tion portion of this section Ensure that the selected mounting site will satisfy the measurement param eters vent length not to...

Страница 11: ...ets The tube ends extend through the flanges to help with alignment 3 Using the four long and four short nuts from the bolt kit 02876 secure the tube set to the burner box As shown in the diagram use...

Страница 12: ...1 Natural Gas and Propane Installation Code 2 In accordance with the current ANSI Z223 1 NFPA 54 National Fuel Gas Code A vent shall not terminate directly above a sidewalk or paved driveway that is l...

Страница 13: ...of the National Fuel Gas Code or the authority having jurisdiction In regions of the country where prevailing winds are consistently higher than 40 mph it may be necessary to terminate the vent system...

Страница 14: ...to be constructed of galvanized sheet metal or other approved noncombustible corrosion resistant material as indicated by state and or local codes 2 For horizontal venting the vent lengths may be as f...

Страница 15: ...flue is a problem the flue length should be shortened or insulated g For vent specifications all of the following conditions must be met The maximum equivalent length of vent pipe should be carefully...

Страница 16: ...ded below the heater for each 1 000 Btu hr of heater input When outside air is used the opening below the heater shall be one square inch of free area for each 4 000 Btu hr of heater input In contamin...

Страница 17: ...lectrical Code ANSI NFPA 70 or Canadian Electrical Code CSA 22 1 if an external electrical source is utilized Gas Service Installation Install Gas Supply Lines A gas supply connection is required as s...

Страница 18: ...burrs 3 Use LP resistant joint compound on all threads 4 Check the pipe and tube connections for leaks before placing heating equipment into service When checking for gas leaks use a soap and water so...

Страница 19: ...hen occur 8 Periodic visual check of burner flame while unit is in operation through sight glass in bottom of unit Section 6 MAINTENANCE Pre Season Maintenance Heater area to be kept clear and free fo...

Страница 20: ...h does not operate Igniter spark gap incorrect Try This Unplug heater power cord from the electrical outlet wait for a minimum of five seconds Plug heater cord back into outlet Unplug heater power cor...

Страница 21: ...essure requirements contact the gas company Check for 24V across valve terminals Check Shutoff On Valve IF NO Check wiring between the ignition module and the valve Repair replace wires as required If...

Страница 22: ...keyed to the associated parts list I B A C J F H G D E ITEM PART NUMBER DESCRIPTION HST 35 HST 45 A 02808 Spark Electrode 1 1 B 02837 Ignition Wire 1 1 C 05735 Orifice HST35 NG 1 05795 Orifice HST 45...

Страница 23: ...er Box for F108847 F102850 HST 45NG Burner Box for F108850 F102851 HST 45LP Burner Box for F108851 B F106000 HST 35 Tube Set Short F106250 HST45 Tube Set Long C 06014 Hanger D 06016 Hanger Clamp E 060...

Страница 24: ...lso supply us with the purchase date and the name and address of the dealer from whom you purchased our product The foregoing is the full extent of the responsibility of the Company There are no other...