Operating Instructions and Owner’s Manual

Enerco | enerRadiant® HST Series Heater

BEFORE YOU BEGIN

Read this manual carefully before installing or servicing this
equipment. Improper installation, servicing or maintenance will
cause death, injury or property damage. Check the minimum
required safe distances from combustibles given on the outside of
each burner to make sure that the product is suitable for your
application. The minimum required safe distances from
combustibles is also found on page 9 of this manual. Installer must
be a licensed contractor of representative. After the installation is
complete, check product operation as provided in these
instructions.

Unpacking the Heater

Manpower Requirements

To prevent personal injury and damage to the heater, two persons
will be required to remove the heater from the carton. Both ends
of the heater should be lifted from the carton at the same time.
The burner box should be lifted by gripping the bottom of the box.
The reflector end of the heater should be lifted using the rear
moveable hanger.

Safety

Thin sheet metal parts, such as the reflector portion of the heater
and the various venting components, have sharp edges. To prevent
injury, the use of work gloves is recommended. The use of gloves
will also prevent the transfer of body oils from the hands to the
surface of the reflector.

Available Accessories

(2) 

Protective Grille Kits

HST-35 Kit includes

 (06035):

(3) Formed Grille

(1) End Grille

HST-45 Kit includes

 (06050):

(4) Formed Grille

(1) End Grilles

Installation Kit

 (02834)

1. (1) ½” x 24" Long Stainless

Flex Hose

2. (1) ½”NPT Ball Shut-Off

Valve

3. (1) ½”NPT Pipe Tee
4. (1) ½” x 4" Long Nipple
5. (1) ½”NPT Pipe Cap

Vent Kit

 (F102840)

1. (2) 3" x 2' Pipe 26GA.
2. (1) 36" x 3" B-Vent
3. (1) Gas Vent Top 3"
4. (1) Adj. Wall Thimble
5. (1) Storm Collar
6. (1) 3" Elbow
7. (1) Adj. Roof Flashing

Section 1 INTRODUCTION

About The Heater

The enerRadiant HST is a factory-assembled, gas fired, low-intensity
heating system. The system has been designed for easy installation
and will provide years of economical operation and trouble-free
service. Not only is infrared heat efficient, it also provides the most
comfortable conditions in open areas, such as garages.

Gas-Fired

 means it uses clean-burning Natural or LP gas.

Low-Intensity

 means that the radiant surface of the heat

exchanger tube does not glow red. Instead, it operates at a lower
temperature (less than 1000 F) and radiates energy at a lower
intensity per square foot of radiating surface. The lower
temperature and intensity levels are within a range that is most
effective in establishing and maintaining personal comfort levels.
An aluminum reflector directs the radiant energy downward to the
occupied area.

Radiant

 refers to the energy radiated by the enerRadiant HST

heater. Because the energy is in the form of infrared rays, it does
not directly heat the air. Instead, the rays heat objects such as the
floor, cars, machines and people. The warm objects, in turn, heat
the air. These combined features are the key to the exceptional
comfort and fuel efficiency provided by the enerRadiant HST
heater.

1

2

3

4

5

6

7

1

2

3

4

5

End Grille

Formed Grille

Содержание enerradiant HST35

Страница 1: ...Installation and service must be performed by a qualified installer service agency or the gas supplier If you cannot reach your gas supplier call the Fire Department Gas Fired Low Intensity Infrared H...

Страница 2: ...pour se conformer aux precautions et aux instructions a fourni avec cet appareil de chauffage avoir pour resultat la mort blessure et la perte de propriete ou les dommages physiques serieuses du dang...

Страница 3: ...ST 45 Kit includes 06050 4 Formed Grille 1 End Grilles Installation Kit 02834 1 1 x 24 Long Stainless Flex Hose 2 1 NPT Ball Shut Off Valve 3 1 NPT Pipe Tee 4 1 x 4 Long Nipple 5 1 NPT Pipe Cap Vent K...

Страница 4: ...y downward to the space to be heated Heat Exchanger A U shaped tube through which the heated products of combustion pass Rear Movable Hanger Provides support for the heat exchanger and reflector at th...

Страница 5: ...NS Electrical Rating 120VAC 60Hz single phase 1 amp Connection 3 pin moulded plug Gas Inlet Connection Connection Male NPT Gas Inlet Pressure The minimum inlet gas supply pressure for the purpose of i...

Страница 6: ...is section provides the following information Defines the gas electric and venting requirements for the enerRadiant HST heater Specifies the national standards and applicable codes that apply to the g...

Страница 7: ...the floor Minimum required safe distances to combustibles must be maintained from vehicles parked below the heater When installed over hoists the minimum required safe distances to combustible must be...

Страница 8: ...as required Choose Location for Heater When selecting a suitable mounting location for the enerRadiant HST heater it is important to consider the following 1 The heater must meet the minimum mounting...

Страница 9: ...3 5kPa WARNING Materials and items when stored under this heater will be subjected to radiant heat and could be seriously damaged 4 All horizontal venting sections must slope away from the heater at...

Страница 10: ...ed through the roof be sure to carefully review the roof option installa tion portion of this section Ensure that the selected mounting site will satisfy the measurement param eters vent length not to...

Страница 11: ...ets The tube ends extend through the flanges to help with alignment 3 Using the four long and four short nuts from the bolt kit 02876 secure the tube set to the burner box As shown in the diagram use...

Страница 12: ...1 Natural Gas and Propane Installation Code 2 In accordance with the current ANSI Z223 1 NFPA 54 National Fuel Gas Code A vent shall not terminate directly above a sidewalk or paved driveway that is l...

Страница 13: ...of the National Fuel Gas Code or the authority having jurisdiction In regions of the country where prevailing winds are consistently higher than 40 mph it may be necessary to terminate the vent system...

Страница 14: ...to be constructed of galvanized sheet metal or other approved noncombustible corrosion resistant material as indicated by state and or local codes 2 For horizontal venting the vent lengths may be as f...

Страница 15: ...flue is a problem the flue length should be shortened or insulated g For vent specifications all of the following conditions must be met The maximum equivalent length of vent pipe should be carefully...

Страница 16: ...ded below the heater for each 1 000 Btu hr of heater input When outside air is used the opening below the heater shall be one square inch of free area for each 4 000 Btu hr of heater input In contamin...

Страница 17: ...lectrical Code ANSI NFPA 70 or Canadian Electrical Code CSA 22 1 if an external electrical source is utilized Gas Service Installation Install Gas Supply Lines A gas supply connection is required as s...

Страница 18: ...burrs 3 Use LP resistant joint compound on all threads 4 Check the pipe and tube connections for leaks before placing heating equipment into service When checking for gas leaks use a soap and water so...

Страница 19: ...hen occur 8 Periodic visual check of burner flame while unit is in operation through sight glass in bottom of unit Section 6 MAINTENANCE Pre Season Maintenance Heater area to be kept clear and free fo...

Страница 20: ...h does not operate Igniter spark gap incorrect Try This Unplug heater power cord from the electrical outlet wait for a minimum of five seconds Plug heater cord back into outlet Unplug heater power cor...

Страница 21: ...essure requirements contact the gas company Check for 24V across valve terminals Check Shutoff On Valve IF NO Check wiring between the ignition module and the valve Repair replace wires as required If...

Страница 22: ...keyed to the associated parts list I B A C J F H G D E ITEM PART NUMBER DESCRIPTION HST 35 HST 45 A 02808 Spark Electrode 1 1 B 02837 Ignition Wire 1 1 C 05735 Orifice HST35 NG 1 05795 Orifice HST 45...

Страница 23: ...er Box for F108847 F102850 HST 45NG Burner Box for F108850 F102851 HST 45LP Burner Box for F108851 B F106000 HST 35 Tube Set Short F106250 HST45 Tube Set Long C 06014 Hanger D 06016 Hanger Clamp E 060...

Страница 24: ...lso supply us with the purchase date and the name and address of the dealer from whom you purchased our product The foregoing is the full extent of the responsibility of the Company There are no other...

Отзывы: