7.1 General

WARNING

DO NOT operate the immersion until the 

water heater has been filled with water.

7.2 Checklist before commissioning

 

`

Check that all installation and discharge pipe 

requirements have been met.

 

`

Check expansion vessel pre-charge pressure. The 

vessel is supplied precharged to 0.35MPa (3.5 

bar) to match the control pressure of the Pressure 

Reducing Valve. The pre-charge pressure is 

checked using a car tyre gauge by unscrewing the 

plastic cap opposite the water connection. 

 

`

Check all water connections are tight.

 

`

Check all electrical connections are tight.

 

`

Check all earth bonding links are connected, tight 

and un-damaged.

 

`

Check earth continuity, short circuits, polarity and 

resistance to earth.

7.3 Commissioning procedure

 

`

Open a hot tap furthest from the water heater and 

turn on the water supply to the water heater.

 

`

Allow water heater to fill and leave hot tap running 

for a short while to purge any air and flush out the 

pipework.

 

`

Open successive hot taps to purge the system of 

air. 

 

`

Check all water connections for leaks and rectify 

as necessary.

 

`

Turn off mains water supply.

 

`

Remove the Pressure Reducing Valve head work 

to access the strainer mesh, clean and re-fit, see 

Figure 9, page 17.

 

`

Turn the water supply back on.

 

`

Manually open, for a few seconds, each relief valve 

in turn, checking that water is discharged and runs 

freely through the tundish and out at the discharge 

point.  

 

`

Ensure that the valve(s) reseat satisfactorily.

 

`

If necessary set the temperature control knob to 

the desired setting (see figure 8, page 16). Factory 

setting is 54

o

C.

 

`

Switch on the electrical supply. The indicator 

light will illuminate during heating. When the set 

temperature is reached the indicator light will go 

out.

 

`

The set temperature can be adjusted by rotating the 

control knob. This can be set to give temperatures 

in the range 10°C to 70°C (see figure 8, page 16). 

In hard water areas it is advised that the maximum 

temperature is restricted to prevent build up of 

scale. Temperatures above 55

o

C can scald so 

consideration should be given to blending at the 

point of use to a safe user temperature.

6.3 Electrical connections

 

`

Check  that  the  electrical  supply  is  of  sufficent 

current rating and voltage, see Technical Data 

page 5.

 

`

A  2  metre  length  of  flexible  cable  is  supplied 

factory  fitted. The  cable  specification  is  H05VV-F 

3G 2.5mm

2

. If replacing or extending the same 

specification of cable should be used.

 

`

The  flexible  cable  must  be  wired  into  an 

appropriately fused switched spur.

 

`

The conductor sheaths are colour coded as follows:

 

Green and Yellow  

EARTH  

 

Brown    

 

LIVE           (L)

 

Blue    

 

NEUTRAL    (N)

In  case  of  difficulty  contact  service  support;  contact 

details are available on page 28

 

of this booklet.

7. Commissioning

WARNING

 

`

Disconnect from the mains electrical 

supply before removing any covers.

 

`

Never attempt to replace the 

immersion heater other than with the 

recommended immersion heater.

 

`

DO NOT bypass the thermal cut-out 

in any circumstances. Ensure the two 

spade terminations on the wires from 

the thermostat and thermal cut-out are 

pushed  firmly  into  the  corresponding 

terminations on the element plate 

assembly.

 

`

All electrical wiring should be carried 

out by a competent electrician and be 

in accordance with the latest I.E.E, 

Wiring  Regulations.

 

`

Each circuit must be protected  by a 

suitable fuse and double pole isolating 

switch with a contact separation of at 

least 3mm in both poles.

 

`

DO NOT operate the immersion heater 

until the appliance has been filled with 

water.

Содержание 7037042

Страница 1: ...Multipoint Vertical 30 100 Litres Installation operation and maintenance manual...

Страница 2: ...manufacturers and installers The purpose is to ensure that customers are provided with the correct equipment for their needs that it is installed commissioned and serviced in accordance with the manuf...

Страница 3: ...ficient maintenance of the appliance Failure to abide by the instructions for installing the product Installer s liability The installer is responsible for the installation and the commissioning of th...

Страница 4: ...ended minimum water pressure 0 08 MPa 0 8 bar Max water pressure1 6 MPa 16 bar see table 1 page 5 If the supply cord is damaged it must be replaced by the manufacturer its service agent or simularly q...

Страница 5: ...duct Name Multipoint 30L V 3kW Multipoint 50L V 3kW Multipoint 80L V 3kW Multipoint 100L V 3kW Suppliers name or trade mark Multipoint Supplier s model identifier 30L V 3kW 50L V 3kW 80L V 3kW 100L V...

Страница 6: ...43 1028 1084 1253 D 626 903 956 1134 E 100 100 100 100 F 371 371 451 451 G 95 95 105 105 H OUTLET 22mm 3 4 BSP M I INLET 22mm 3 4 BSP M J TEMPERATURE PRESSURE RELIEF VALVE DISCHARGE PIPE CONNECTION 15...

Страница 7: ...TY BLACK WIRE A TERMINAL BLOCK ELEMENT EARTH IMMERSION STUD L N E OUTER CLADDING L N THERMOSTAT ADJUSTMENT SPINDLE FACTORY SET AT 54 C 2 1 B A RESET CUT OUT TO ELEMENT CUT OUT SENSOR THERMOSTAT SENSOR...

Страница 8: ...pressure to the tap or shower an unvented water heater uses the incoming mains water pressure To do this the water heater is sealed and not vented However when the volume of water is heated it expands...

Страница 9: ...r consistently contains a high proportion of solids e g suspended matter that could block the strainer unless adequate filtration can be ensured In areas where the water supply contains chloride level...

Страница 10: ...fitted Temperature Pressure Relief valve be removed other than by a competent person To do so would invalidate any warranty claim The cold water controls supplied MUST be fitted on the mains water sup...

Страница 11: ...ical installation table supplied and should be fitted A suitable draining tap should be installed in the cold water supply to the appliance between the Expansion Valve and the appliance at as low a le...

Страница 12: ...ve with no more than 600mm of pipe between the valve outlet and the tundish see Fig 7 Note To comply with the Water Supply Water Fittings Regulations the tundish should incorporate a suitable air gap...

Страница 13: ...able providing that a wire cage or similar guard is positioned to prevent contact whilst maintaining visibility and c discharges at high level e g into a metal hopper and metal downpipe with the end o...

Страница 14: ...p to 27m 1 4m 1 7m 2 3m Table 6 Sizing of copper discharge pipe D2 for common temperature relief valve outlet sizes Safety device e g Temperature relief valve Metal discharge pipe D1 from Temperature...

Страница 15: ...g heating When the set temperature is reached the indicator light will go out The set temperature can be adjusted by rotating the control knob This can be set to give temperatures in the range 10 C to...

Страница 16: ...given under the section headed MAINTENANCE COLD HOT WARNING If the appliance is to be left unused followinginstallationandcommissioning e g unocupied properties the appliance should be drained or regu...

Страница 17: ...pecting the water heater internally Safety valve operation CAUTION Water discharged may be very hot Manually operate the Temperature Pressure Relief Valve for a few seconds Check water is discharged a...

Страница 18: ...ance interior Ensure sealing surfaces are clean and seals are undamaged if in doubt fit a new gasket Replace immersion heater ensuring correct orientation One of the bolt holes uses a larger bolt to e...

Страница 19: ...Check and adjust setting if required Replace if necessary Element Failure Replace EPA Discharge of water from Expansion pressure relief valve continuously Excessive mains water pressure Check pressure...

Страница 20: ...lect The appliance has not been subject to wilful or accidental damage caused by your negligence Regular maintenance has been carried out by a competent person or a Heatrae Sadia authorised engineer i...

Страница 21: ...y Users in Private Households in the European Union This symbol on the product indicates that this product must not be disposed of with your other household waste Instead it is your responsibility to...

Страница 22: ...22 13 Spare parts 18 9 4 15 16 5 17 3 20 21 22 1 2 19 Figure 11 Spare parts...

Страница 23: ...ion relief valve 0 6 Mpa 6 bar not shown 95607986 11 Pressure reducing valve not shown 95605082 12 Tundish not shown 95605838 13 Non return valve 22mm not shown 7037720 14 Indicator light BBSC not sho...

Страница 24: ...24...

Страница 25: ...25...

Страница 26: ...26...

Страница 27: ...27...

Страница 28: ...rporate responsibility and sustainability charters and reduce our printed material we encourage you to download product brochures from our website In designing these files we have taken into account t...

Отзывы: