21
Touch
Series
Section Header
Feature 10 – Optimum Start:
Optimum start will delay the start up of the heating system
to the latest possible moment to avoid unnecessary heating and ensure the building is
warm at the programmed time. The thermostat uses the rate of change information to
calculate how long the heating needs to raise the building temperature 1°C (with a rate
of change of 20, the thermostat has calculated the heating needs 20 minutes to raise the
building temperature 1°C) and starts the heating accordingly.
Feature 11 – Rate Of Change:
This is the number of minutes the thermostat has calculated
it takes to raise your building temperature 1°C. The thermostat will continue to monitor
and learn the heat up time of your home to optimise heating efficiency.
Feature 12 - Programming Mode:
The thermostat offers 2 programming methods.
Weekday/Weekend allows you to program 4 comfort levels for the weekdays and
4 different comfort levels for the weekend. In 7 Day program mode, each day has 4
comfort levels that can be programmed independently.
Optional Features Continued