background image

9

Touch 

Series

Section Header

To set the clock, follow these steps.

•   Press PROG  ...............................................................................................................
•   Press CLOCK  .............................................................................................................
•   Use the Down key to set the hours  .................................................................
•   Use the Up key to set the minutes  ..................................................................
•   Use the Day key to set the day of the week  .................................................
•   Press DONE to confirm and exit ........................................................................

Setting the Clock

Hours

Change Hours

Minutes

Day

Change Minutes

Содержание touch-n

Страница 1: ...Model Touch N...

Страница 2: ...1 Touch Series Model Touch N...

Страница 3: ...ature Display Comfort Levels Explained Clean Screen Locking the Keypad Temperature Control 15 16 17 18 19 21 22 23 24 25 26 27 28 Temperature Hold Holiday Programming Frost Protection Heating ON OFF O...

Страница 4: ...t will allow you to select different temperatures in your home at different times of the day and days of the week to meet your particular needs and preferences Setting a room thermostat to a higher te...

Страница 5: ...diator valves TRVs on individual radiators If you don t have TRVs you should choose a temperature that is reasonable for the whole house If you do have TRVs you can choose a slightly higher setting to...

Страница 6: ...tom face of the thermostat Step 2 Place the thermostat front somewhere safe Terminate the thermostat as shown in the diagrams on pages 27 28 of this booklet Step 3 Screw the thermostat back plate secu...

Страница 7: ...Section Header Model Touch N 6 1 2 3 4...

Страница 8: ...7 Touch Series Section Header 1 4 3 2 5 10 19 18 14 6 11 12 13 16 20 7 15 9 8 17...

Страница 9: ...rn off display 9 Frost Icon Displayed when the thermostat is in frost protection mode 10 Floor Temp Achieved Icon Displayed when the floor set point temperature is reached 11 Room Floor Temp Indicates...

Страница 10: ...follow these steps Press PROG Press CLOCK Use the Down key to set the hours Use the Up key to set the minutes Use the Day key to set the day of the week Press DONE to confirm and exit Setting the Cloc...

Страница 11: ...rature Pressing FLOOR again will return the thermostat to the room temperature display Room Floor Temperature SET Temperature Temperature Display The temperature display information is driven by two d...

Страница 12: ...ng options 5 2 Day Programming 4 levels for the weekdays and 4 different levels for the weekend 7 Day Programming 4 levels for each day See page 21 for details on how to switch between these modes Tip...

Страница 13: ...e temperature Repeat these steps for the LEAVE RETURN SLEEP periods Press DAY to select the next day to program and repeat When complete press DONE to confirm settings and exit In 5 2 Day mode the the...

Страница 14: ...tom right corner of the display and hold for 10 secs When activated you will see the Keypad Lock symbol To cancel press the bottom right corner of the display again for 10 secs Clean Screen Pressing w...

Страница 15: ...these keys you will see the temperature and the word SET appear on screen Select the desired temperature and press to confirm and exit Note This new temperature is maintained only until the next prog...

Страница 16: ...fferent temperature for a desired period Press HOLD Use the top set of Up Down keys to set the hold period Use the center set of Up Down keys to set the hold temperature Press DONE to confirm and exit...

Страница 17: ...n to the program mode on your return Press HOLIDAY Enter the desired duration in days Press DONE to confirm and exit To cancel a Holiday setting reduce the Holiday time to 00 days Holiday Holiday Icon...

Страница 18: ...stat will display the frost icon and will only turn the heating on should the room temperature drop below the set frost temperature see page 19 Should the heating be turned on whilst in frost mode the...

Страница 19: ...t for heating to achieve the set temperature but the thermostat remains active To turn the thermostat OFF completely press and hold the OFF key The display and heating output will be turned off comple...

Страница 20: ...erature is achieved Feature 03 Frost Protect You can set whether the thermostat will maintain the frost temperature when the thermostat display is turned off As a default this is enabled Feature 04 Fr...

Страница 21: ...the set temperature by monitoring the remote air sensor 02 Floor sensor In this mode the thermostat will maintain the set temperature by monitoring the remote floor temperature 03 Floor sensor and bu...

Страница 22: ...0 minutes to raise the building temperature 1 C and starts the heating accordingly Feature 11 Rate Of Change This is the number of minutes the thermostat has calculated it takes to raise your building...

Страница 23: ...ress PROG Press SETUP Use the Up Down keys at the top of the screen to select the feature number shown on pages 19 21 and then use the Up Down keys in the center to adjust the setting Press DONE to co...

Страница 24: ...Mode DESCRIPTION 00 C 01 F C Default 0 5 3 0 C 1 C Default 00 Disabled 01 Enabled 01 Default 07 17 C 12 C Default Enter Value 00 15 Minutes 00 Default Enter number 01 32 00 10 C 00 Default 00 Built i...

Страница 25: ...ault You should contact your thermostat retailer for assistance E1 The remote floor probe has not been connected has been wired incorrectly or the probe is faulty E2 The remote air probe has not been...

Страница 26: ...low these steps Press and hold the OFF key to turn the thermostat OFF Press and hold the ON key until the temperature appears on the screen Use the Up Down keys to configure the new temperature Press...

Страница 27: ...ettings to their factory defaults To perform a factory reset follow these steps Press hold the OFF key to turn the thermostat display OFF Press and hold the bottom left corner of the LCD for 10 second...

Страница 28: ...required Y B A1 RT1 Floor Sensor UH1 ZONE X A2 A1 B Y _ A2 A1 B Y _ Connecting Touch N to the UH1 The UH1 is an 8 zone wiring centre that can be expanded to control up to 32 zones When connecting Touc...

Страница 29: ...r 230V switched live output link mains L to C Y B A1 RT1 RT2 A2 B2 NO NC C NO NC C N E L 230V SUPPLY IN COMMS CABLE Volt Free Output POWERED RELAY CARD 12V Touch N A2 12VDC Network Air Floor Recommend...

Страница 30: ...Model Manual REF 29 Notes 29 Touch Series...

Страница 31: ...Model Touch N 30 Notes...

Страница 32: ...More Information PDF FAQ Call our support team on 44 0 1254 669090 Or view technical specifications directly on our website www heatmiser com Twitter heatmiseruk Facebook facebook com thermostats Rev...

Отзывы: