Feature 07 – Floor Temp Limit:
When the Floor Sensor has been enabled in
feature 06, you can set a floor limiting temperature between 20-45°C, this
protects the floor from overheating.
(27°C is the default).
Feature 08 – Optimum Start:
Optimum start will delay the start up of the heating
system to the latest possible moment to avoid unnecessary heating and ensure
the building is warm at the programmed time. The thermostat uses the rate of
change information to calculate how long the heating needs to raise the building
temperature 1°C (with a rate of change of 20, the thermostat has calculated the
heating needs 20 minutes to raise the building temperature 1°C) and starts the
heating accordingly.
Feature 09 – Rate Of Change:
This is the number of minutes the thermostat has
calculated it takes to raise your building temperature 1°C. The thermostat will
continue to monitor and learn the heat up time of your home to optimise heating
efficiency.
Feature 10 – Programming Mode
: The following program modes are available;
5/2 Day Programming – 4 levels for the weekdays and 4 different levels for
the weekend.
7 Day Programming – 4 levels for each day.
24 Hours – 4 levels over a 24-hour period.
Feature 11 – Thermostat Mode:
Here you can set in which mode you would
like the thermostat to operate. The options are, manual (non-programmable) or
programmable (Comfort Levels).
Model: Slimline-E V3
22
Содержание Slimline Series
Страница 1: ...Model Slimline E V3 ...
Страница 2: ...1 Slimline Series Model Slimline E V3 ...
Страница 7: ...1 2 3 4 Model Slimline E V3 6 ...
Страница 9: ...Mode 1 Thermostat Model Slimline E V3 8 ...
Страница 10: ...1 2 3 4 5 13 6 7 8 9 10 11 12 9 Slimline Series ...
Страница 29: ...7 1 2 3 5 6 4 8 Model Slimline E V3 28 ...
Страница 40: ... Model Manual REF 39 Notes 39 Slimline Series ...
Страница 41: ... Notes Model Slimline E V3 ...