30
29
TouchScreen
Series
Model:
PRT-ETS / PRT-ENTS
Wiring Diagram - PRT-ENTS
Optional Remote Air Sensor Connection For Use In Wet Areas
Wiring Diagram - PRT-ENTS to PRC
PRT-ENTS for use in wet area where floor temperature control or limiting is required.
PRT-ENTS
Y
B
A2
A1
-
+
Network
RT1
RT2
Floor
Sensor
12VDC
Remote
Air Sensor
UH1
ZONE X
A2
A1
B
Y
_
+
ZONE X
A2
A1
B
Y
_
+
Connecting PRT-ENTS to the UH1
The UH1 is an 8 zone wiring centre that
can be expanded to control up to 32 zones.
When connecting PRT-ENTS to the UH1 use
CAT5-FTP or BELDEN 9538.
Connect the screen to Earth at the UH1.
Floor
Air
PRT-ENTS
Y
B
A2
A1
-
+
12VDC
Network
Air
Floor
RT1
RT2
A2
B2
NO NC C
NO NC C
N E
L
230V SUPPLY IN
COMMS
CABLE
Volt Free Output
POWERED RELAY CARD
+
_
For 230V switched live output, link mains L to C
12V
Recommendations
Max Cable Size - 1.5MM
Back Box Depth - 35MM
Max Load - 3 Amps