ASSOCIATION GROUPS WITHOUT MULTICHANNEL SUPPORT

When used in a system without Multi  Channel support:

THERMOSTAT DEVICE

THE MAIN THERMOSTAT DEVICE

Group 1

Lifeline

Lifeline. (Normally used by the Z-Wave Control-

ler) Sends: 

- Device Reset Notifications.

- Thermostat Setpoint Reports

- Thermostat Mode Reports

- Thermostat Operating State

- Basic Reports

- Meter Reports 

Max. nodes in group: 5

Group 2

State of relay ON/OFF

Send Binary Switch Set commands representing 

the status of the internal relay.

Max. nodes in group: 5

Group 3

Internal sensor

Send Multilevel Sensor Reports for internal 

temperature sensor. 

Max. nodes in group: 5

Group 4

External sensor

Send Multilevel Sensor Reports for external 

room temperature sensor.

Max. nodes in group: 5

Group 5

Floor sensor

Send Multilevel Sensor Reports for floor sensor.

Max. nodes in group: 5

24.  CONFIGURATION PARAMETERS

Z-Wave products are supposed to work out of the box after inclusion. 
Some device configuration may, however, alter the functionality to 
better serve user needs or unlock further enhanced features.

Parameter 1,

 Parameter Size 1. 

Operation mode

VALUE

DESCRIPTION

0

Off

1

Heating mode (Default)

Parameter 2,

 Parameter Size 1. 

Sensor mode

VALUE

DESCRIPTION

0

F-mode, floor sensor mode

1

A-mode, internal room sensor mode (Default)

2

AF-mode, internal room sensor with floor limitation

3

A2-mode, external room sensor mode

4

A2F-mode, external sensor with floor limitation

Parameter 3, 

Parameter Size 1. 

Floor sensor type

VALUE

DESCRIPTION

0

10K NTC (Default)

1

12K NTC

2

15K NTC

3

22K NTC

4

33K NTC

5

47K NTC

Parameter 4, 

Parameter Size 1. 

Temperature control hysteresis (diF)

VALUE

DESCRIPTION

3 to 30

0.3°C to 3.0°C. Default is 5 (0.5°C)

Parameter 5, 

Parameter Size 2. 

Floor minimum temperature limit (Flo)

VALUE

DESCRIPTION

50 to 400

5.0°C to 40.0°C. Default is 50 (5.0°C)

MULTICHANNEL SUPPORT

Heatit Z-TRM3 has support for the Multichannel Command Class. This 
allows the thermostat to be perceived as many devices by the primary 
controller, where each of the devices has association groups in order to 
send information to other Z-Wave devices. See the chapter concerning 
”Association Groups” for more information. Commands sent to each 
logical device will be interpreted according to the description in the 
section ”Supporting Command Classes”.

NO MULTICHANNEL SUPPORT

If the primary controller or the Z-Wave devices to be associated with 
Heatit Z-TRM3 do not support the Multichannel Command Class 
(Multichannel encapsulation), only the association groups in the root 
device are accessible. This device contains 5 association groups. 
See Chapter 23 concerning ”Association Groups” for more information. 
The root device is the actual thermostat device.

ASSOCIATION GROUPS  WITH MULTICHANNEL SUPPORT

When used in a system with Multichannel support:

THERMOSTAT DEVICE 1

THE MAIN THERMOSTAT DEVICE

Group 1

Group 2

Lifeline. (Normally used by the Z-Wave Control-

ler) Sends:

-Thermostat Setpoint Reports

-Thermostat Mode Reports

-Thermostat Operating State

-Meter Reports

Max. nodes in group: 5

Send Binary Switch Set commands representing 

the status of the internal relay.

Max. nodes in group: 5

MULTILEVEL SENSOR 
DEVICE 2

DEVICE FOR INTERNAL ROOM 
TEMPERATURE SENSOR

Group 1

Group 2

Lifeline

Send Multilevel Sensor Reports. 

Max. nodes in group: 5

Send Multilevel Sensor Reports. 

Max. nodes in group: 5

MULTILEVEL SENSOR 
DEVICE 3

DEVICE FOR EXTERNAL ROOM 
TEMPERATURE SENSOR

Group 1

Group 2

Lifeline

Send Multilevel Sensor Reports. 

Max. nodes in group: 5

Send Multilevel Sensor Reports. 

Max. nodes in group: 5

MULTILEVEL SENSOR 
DEVICE 4

DEVICE FOR FLOOR SENSOR

Group 1

Group 2

Lifeline

Send Multilevel Sensor Reports. 

Max. nodes in group: 5

Send Multilevel Sensor Reports. 

Max. nodes in group: 5

Содержание HEATIT Z-TRM3

Страница 1: ...etwork to communicate with the other devices within it Devices may also be removed from a network The add remove processes are initiated by the primary controller of the Z Wave network The primary controller has a mode for adding or removing devices Please refer to your primary controller manual on how to set the primary controller in add remove mode The device may only be added or removed from th...

Страница 2: ...ller is in add remove mode When the device is removed from the network it will NOT revert to factory settings There are two ways to add the Heatit Z TRM3 to a Z Wave network 6 1 METHOD 1 STANDARD MANUAL 1 Press Center confirm for 10 seconds The display will show OFF 2 Press Right down 5 times until you see Con on the display 3 Start the add remove device process in your primary controller 4 Start ...

Страница 3: ...cture OFF Turns the thermostat off Sensors CHOICE OF SENSORS F Depending on your choice of sensors the menu will change SEn Select the right Ohm value for your external floor sensor NTC type 10 12 15 22 33 or 47kΩ Default 10kΩ CAE Calibration for external sensor CAF Calibration for floor sensor CAr Calibration for internal sensor br1 The display brightness may be adjusted in this menu Con Activati...

Страница 4: ... pressing Left and Right up and down buttons for 10 seconds OPn will appear on the display 19 ERROR CODES Err Adding fail See Chapter 6 1 Add Remove Er1 Internal error Contact your local dealer Er2 Z Wave error Contact your local dealer Er3 Internal error Contact your local dealer Er4 Floor sensor error You have chosen F AF or A2F sensor mode without having a floor sensor connected or the sensor m...

Страница 5: ...PTION 50 to 400 5 0 C to 40 0 C Default is 50 5 0 C MULTICHANNEL SUPPORT Heatit Z TRM3 has support for the Multichannel Command Class This allows the thermostat to be perceived as many devices by the primary controller where each of the devices has association groups in order to send information to other Z Wave devices See the chapter concerning Association Groups for more information Commands sen...

Страница 6: ...1 Display brightness active state Configure the brightness of the display in active state VALUE DESCRIPTION 0 to 100 0 to 100 Default 100 Parameter 18 Parameter Size 2 Temperature report interval Time interval between consecutive temperature reports Temperature reports can also be sent as a result of polling VALUE DESCRIPTION 30 to 32767 30 seconds to 32767 seconds Default is 60 seconds Parameter ...

Страница 7: ...umulated Watt instant andVolt instant The thermostat will report when asked Rate import Import 0x01 Meter type Electric meter 0x01 Precision 1 decimal 0x01 PRECISION VALUE SCALE SUPPORTED VALUE SIZE 1 decimal 0x01 kWh 0x01 4 2 decimals 0x01 W 0x02 4 1 decimal V 0x04 2 THERMOSTAT DEVICE 1 Supported Command Classes Association version 2 Z Wave Plus Information version 2 Association version 2 Associa...

Страница 8: ...12 15 22 33 and 47 kΩ 25 C IP Code IP 21 Approvals Z Wave Plus CE EN 60730 1 EN 60730 2 9 EMC 2014 30EU RoHS 2011 65 EU LVD 2014 35 EU Approved for use in bathrooms TERMINAL Use 1 5mm or 2 5mm according to load MAINTENANCE The product is maintenance free but must not be covered ART NO PRODUCT COLOR Z WAVE FREQUENCY 54 305 99 Heatit Z TRM3 thermostat 3600W 16A White RAL 9003 EU 868 4MHz 54 305 98 H...

Отзывы: