NOVUS DIRECT VENT INSTALLATION INSTRUCTIONS
b. Intermittent Pilot Ignition
1)
This appliance requires a 110VAC supply to the appliance junction box for operation. A wiring diagram is
shown in Figure 45.
2)
This appliance is equipped with an intermittent pilot control valve which operates on a 3 volt system.
3)
This appliance is supplied with a battery pack and a 3 volt AC transformer, which requires the installation
of the supplied junction box. We highly recommend that the junction box be installed at this time to avoid
reconstruction. The battery pack requires two D cell batteries (not included). Batteries cannot be placed in
the battery pack while using the 3 volt AC transformer. Conversely, the transformer must be unplugged if the
battery pack is used.
c. Optional Accessories Requirements
Wiring for optional accessories should be done now to avoid reconstruction.
Figure 45 - Intermittent Pilot Ignition Wiring Diagram
Note:
This appliance must be electrically wired and grounded in accordance with local codes or, in
the absence of local codes, with
National Electric Code ANSI/NFPA 70-latest edition
or the
Canadian
Electric Code, CSA C221.1
.
CAUTION:
Battery polarity must be correct or control module damage will occur.