Heatilator NDV3630I-B Скачать руководство пользователя страница 2

Heatilator  • NDV3630I-B, NDV3933I-B, NDV4236I-B, NDV4236I-NVR, NDV4842I-B Owner’s Manual  •  2382-981 Rev. N  •  5/22 

2

Listing Label Information/Location

A. Congratulations

Congratulations on selecting a Heatilator gas fireplace, an 

elegant and clean alternative to wood burning fireplaces. 

The Heatilator gas fireplace you have selected is designed 

to provide the utmost in safety, reliability, and efficiency.
As the owner of a new fireplace, you’ll want to read and 

carefully follow all of the instructions contained in this 

owner’s manual. Pay special attention to all cautions and 

warnings.

This  owner’s manual

 

should be retained for future 

reference. We suggest that you keep it with your other 

important documents and product manuals.
The information contained in this owner’s manual, unless 

noted otherwise, applies to all models and gas control 

systems.

Your new Heatilator gas fireplace will give you years of 

durable use and trouble-free enjoyment. Welcome to the 

Heatilator family of fireplace products!

Gas and Electric 

Information

Serial Number

Type of Gas

The model information regarding your specific fireplace can be found on 

the rating plate usually located in the control area of the fireplace.

Model Number

Read this manual before operating this appliance. 

Please retain this Owner’s Manual for future reference.

Read the Installation Manual before making any installation or finishing changes.

Welcome  

Brand: ________________________________________________ Model Name: ___________________________

Serial Number: __________________________________________ Date Installed: __________________________

Appliance Information:

Local Dealer Information

DEALER:

 

Fill in 

your name, address, 

phone and email 

information here and 

appliance information 

below.

Dealer Name: ________________________________________________________
Address: ____________________________________________________________
               ____________________________________________________________
Phone:   _____________________________________________________________
Email:    _____________________________________________________________

Minimum Permissible Gas Supply for Purposes of Input Adjustment.

Approved Minimum (De Gaz) Acceptable ............................ x.x in. w.c. (Po. Col. d’eau)

Maximum Pressure (Pression) ............................................xx.x in. w.c. (Po. Col. D’eau)

Maximum Manifold Pressure (Pression)................................x.x in. w.c. (Po. Col. d’eau)

Minimum Manifold Pressure (Pression).................................x.x in. w.c. (Po. Col. d’eau)

Minimum rate with variable regulator on control valve

Total Electrical Requirements: 120Vac, 60Hz., less than 12 Amperes

MADE IN USA

USA

CANADA

ALTITUDE:..............................0-2000 FT................0-4500 FT.
MAX. INPUT BTU/h ................xx,xxxx....................xx.xxx
MIN. INPUT BTU/h .................xx.xxx......................xx.xxx
ORIFICE SIZE ........................#xx DMS .................#xx DMS

Model:

(Modèle): XXXXXXXXX

Serial:

(Série):

Xxxx-xxx

Heatilator, a brand of Hearth & Home Technologies

7571 215th Street West, Lakeville, MN 55044

Vented gas fireplace heater - Not for use with solid fuel. Appareil de

de foyer avec conduit d’évacuation des gaz – n’utilisez pas avec des

NATURAL GAS

Type of Gas (Sorte De Gaz):

This appliance must be installed in accordance with local codes, if any; if none, follow the National Fuel Gas Code, ANSI Z223.1/NFPA 54, or the

Natural Gas and Propane Installation Code, CSA B149.1

le

. Cet appareil doit être installé conformément aux codes locaux, s’il y a lieu; sinon, suivez

National Fuel Gas Code, ANSI Z223.1/NFPA 54, ou le Code d’installation du gaz naturel et du propane (Natural Gas and Propane Installation Code),

CSAB149.1.
For a manufactured home (USA only) or mobile home OEM installation: This appliance must be installed in accordance with the Standard for

Manufactured Housing, CAN/CSA Z240MH

Manufactured Home Construction and Safety Standard, Title 24 CFR, Part 3280

, in Canada; or with the

in

the United States; or when such a standard is not applicable, the Standard for Manufactured Home Installations Standard, ANSI/NCSBCS

A225.1/NFPA 501A. Pour une installation dans une maison préfabriquée (É.-U. seulement) ou dans une maison mobile du constructeur OEM : Ce

poêle doit être installé en conformité avec la norme visant les maisons préfabriquées,

au Canada; ou avec la

d

e

r

u

t

c

a

f

u

n

a

M

,

H

M

0

4

2

Z

A

S

C

/

N

A

C

r

o

f

d

r

a

d

n

a

t

S

0

8

2

3

tr

a

P

,

R

F

C

4

2

e

lt

i

T

,

d

r

a

d

n

a

t

S

y

t

e

f

a

S

d

n

a

n

o

it

c

u

rt

s

n

o

C

e

m

o

H

aux États-Unis; ou, si une telle norme n’est pas applicable, la

Manufactured Home Installations,ANSI/NCSBCSA225.1/NFPA501A.

QRCODE

QRCODE

INSTALLATION MANUAL

OWNER’S  MANUAL

For use only with barrier(s):  N’utiliser qu’avec la (les) barrière(s) :
____________

____________

Follow installation instructions. Suivre les instructions d'installation.

M XXXXX

H

ANSI XX.XX-XXXX · CSA X.XX-XXXX

CAN/CSA- P.X.X-XX · FE: ___%

FO

R E

XA

MP

LE

ON

LY

chauffage 

combustibles solides.

Содержание NDV3630I-B

Страница 1: ...mable vapors and liquids in the vicinity of this or any other appliance What to do if you smell gas DO NOT try to light any appliance DO NOT touch any electrical switch DO NOT use any phone in your b...

Страница 2: ...Pressure Pression xx x in w c Po Col D eau Maximum Manifold Pressure Pression x x in w c Po Col d eau Minimum Manifold Pressure Pression x x in w c Po Col d eau Minimum rate with variable regulator on...

Страница 3: ...Tasks 14 B Maintenance Tasks Homeowner 14 C Maintenance Tasks Qualified Service Technician 16 5 Frequently Asked Questions and Troubleshooting A Frequently Asked Questions 17 B Troubleshooting 18 6 R...

Страница 4: ...te of Product shipment from HHT regardless of the installation or occupancy date The term Lifetime in the table below is defined as 20 years from the beginning date of warranty coverage for gas applia...

Страница 5: ...or handling devices such as exhaust fans or forced air furnaces or other such causes 6 use of fuels other than those specified in the operation instructions 7 installation or use of components not su...

Страница 6: ...ed as primary heat in residential heating calculations NOTICE This installation must conform with local codes In the absence of local codes you must comply with the National Fuel Gas Code ANSI Z223 1...

Страница 7: ...er is not present or help is needed to properly install one Consider not using the fireplace when children will be present Contact your dealer for more information or visit www hpba org Product Info F...

Страница 8: ...CEILING 42 in 12 in 123 F 115 F 120 F 132 F 145 F 170 F 180 F APPLIANCE FRONT APPLIANCE OPENING 110 F NOTICE Surface temperatures listed above are taken with a temperature measuring probe as prescribe...

Страница 9: ...urer and from model to model actual TV temperatures should be validated at the time of each installation TVs should not be used in situations where the actual TV temperature exceeds the manufacturers...

Страница 10: ...all shipping materials have been removed from inside and or underneath the firebox Review proper placement of logs ember material and or other decorative materials Check the wiring Check the air shutt...

Страница 11: ...e person Immediately call your gas supplier from a neighbor s phone Follow the gas sup plier s instructions If you cannot reach your gas supplier call the fire department C Use only your hand to push...

Страница 12: ...while using electrical power to operate the fireplace Remove batteries from battery tray when power has been restored To Operate Fireplace Using Battery Power DC 1 Access the control cavity of the ap...

Страница 13: ...nic system The term Intermittent is used because the pilot burner flame is only present when the main burner is operating When the main burner is off the pilot is also off NOTICE Batteries should not...

Страница 14: ...ace shall be turned off and cooled before servicing When properly maintained your fireplace will give you many years of trouble free service Contact your dealer to answer questions regarding proper op...

Страница 15: ...prevent unin tended operation Remove batteries from remote controls Unplug 3 volt adapter plug on IPI models Clean glass with a non abrasive non ammonia based commercially available gas fireplace gla...

Страница 16: ...should be avoided Remove all foreign objects Verify unobstructed air circulation Figure 4 2 IPI Pilot Flame Pattern Pilot and Burner Ignition and Operation Frequency Annually By Qualified Service Tech...

Страница 17: ...eral hours This is caused by the curing of the paint and the burning off of any oils remaining from manufacturing Odor may also be released from finishing materials and adhesives used around the firep...

Страница 18: ...dule is fine Inspect pilot assembly for shorted sparker wire or cracked insulator around electrode Replace pilot if necessary 2 Pilot won t light there is no noise or spark A No power or transformer i...

Страница 19: ...gnition Verify cor rect pilot orifice is installed and gas inlet is set to pressure specifications Polish flame sensing rod with fine steel wool to remove any contaminants that may have accumulated on...

Страница 20: ...d accessories could result in a safety hazard and will void the warranty Decorative Doors and Fronts WARNING Risk of Fire Install ONLY doors or fronts approved by Hearth Home Technologies Unapproved d...

Страница 21: ...ice Parts Beginning Manufacturing Date Feb 2016 Ending Manufacturing Date Active Manufacturing Reactivation Date May 2022 NDV3630I B NDV3933I B NDV4236I B NDV4842I B NDV4236I NVR Novus Gas Fireplace D...

Страница 22: ...order overlay CUST4018 001 4055 194 9 4055 133 10 Glass Latch Assembly Qty 4 req 2382 400 Y 11 Dry Wall Lip 4031 205 12 Exhaust Baffle 2382 129 13 Glass Shield 4031 217 14 Hearth Pan 2380 111 15 Burn...

Страница 23: ...order overlay CUST4018 001 4055 195 9 4055 133 10 Glass Latch Assembly Qty 4 req 2382 400 Y 11 Dry Wall Lip 4031 206 12 Exhaust Baffle 2382 129 13 Glass Shield 4031 218 14 Hearth Pan 2381 111 15 Burn...

Страница 24: ...tch Assembly Qty 4 req 2382 400 Y 11 Dry Wall Lip 4031 207 12 Exhaust Baffle 2382 129 13 Glass Shield 4031 219 14 Hearth Pan 2382 111 15 Burner Assembly 2382 007 Y 16 Valve Assembly Refer to valve pag...

Страница 25: ...t order overlay CUST4018 001 4055 197 9 4055 133 10 Glass Latch Assembly Qty 4 req 2382 400 Y 11 Dry Wall Lip 4031 208 12 Exhaust Shield 2382 129 13 Glass Shield 4031 220 14 Hearth Pan 2383 111 15 Bur...

Страница 26: ...y 2382 584 16 7 Valve Bracket 4055 205 16 8 Valve NG 750 500 Y Valve Propane 2155 501 Y 16 9 Brass Fitting Pkg of 5 303 315 5 Y 16 10 3 Volt Transformer SRV593 593 Y 16 11 Module 593 592 Y 16 12 Modul...

Страница 27: ...________________________________________________________________________________ ________________________________________________________________________________ ______________________________________...

Отзывы: