Latches

(both bottom 

and top)

Glass 

Assembly

Figure 4.1  Glass Assembly

Glass Cleaning

Frequency: 

Seasonally

By: 

Homeowner

Tools  Needed

:    Protective  gloves,  gas  fireplace  glass 

cleaner, drop cloth and a stable work surface.

CAUTION! 

Handle  fixed  glass  assembly  with  care. 

Glass is breakable.

•  Avoid striking, scratching or slamming glass

•  Avoid abrasive cleaners

• 

DO NOT

 clean glass while it is hot

 

Prepare a work area large enough to accommodate fixed 

glass assembly and decorative barrier front by placing a 

drop cloth on a flat, stable surface.

Note

: Fixed glass assembly and gasketing may have res

-

idue that can stain carpeting or floor surfaces.

 

Remove decorative barrier front (or decorative front) from 

fireplace and set  aside on work surface.

B.  Maintenance Tasks - Homeowner

The  following  tasks  may  be  performed  annually  by  the 

homeowner.  If you are uncomfortable performing any of 

the listed tasks, please call your dealer for a service ap

-

pointment.
More frequent cleaning may be required due to excessive 

lint from carpeting, bedding material,

 

etc. It is imperative 

that control compartments, burners and circulating air 

passageways of the appliance be kept clean.  Any safety 

screen, guard, or barrier removed for servicing the appli-

ance must be replaced prior to operating the appliance.

CAUTION! 

Risk of Burns! 

The fireplace shall be turned 

off and cooled before servicing. 

When  properly  maintained,  your  fireplace  will  give  you 

many years of trouble-free service.  

Contact your dealer 

to answer questions regarding proper operation, trouble-

shooting and service for your appliance.  Visit www.heati-

lator.com to locate a dealer.  We recommend annual ser-

vice by a qualified service technician. 

IMPORTANT!   Any  safety  screen,  decorative  barrier  front  

or guard removed for servicing must be replaced prior to 

operating the fireplace.

Installation and repair should be done by a qualified service 

technician only. The appliance should be inspected before 

use and at least annually by a professional service person. 

Maintenance and Service 

Task

Frequency

To be completed by

Glass Cleaning

Seasonally 

Homeowner

Surrounds, 

Decorative Barrier 

Fronts

Annually

Remote Control

Seasonally

Venting

Seasonally

Gasket Seal and 

Glass Inspection

Annually

Qualified Service 

Technician

Log Inspection 

Annually 

Firebox Inspection

Annually

Control 

Compartment &  

firebox Top

Annually

Burner Ignition & 

Operation

Annually

Electrical Service 

and Repair

As needed

A.  Maintenance:  Frequency and Tasks

WARNING! 

Risk  of  Asphyxiation! 

Handle  fixed  glass 

assembly  with  care.  Inspect  the  gasket  to  ensure  it  is 

undamaged  and  inspect  the  glass  for  cracks,  chips  or 

scratches. 

• 

DO NOT

 

strike, slam or scratch glass.

• 

DO NOT

 

operate fireplace with glass removed, cracked, 

broken or scratched.

• 

Replace as a complete assembly.

•  Pull the four (two upper and two lower)  glass assembly 

latches out of the groove on the glass frame. Refer to 

Figure 4.1.

•  Remove the glass assembly from the appliance.

Содержание NDV3630I-B

Страница 1: ...mable vapors and liquids in the vicinity of this or any other appliance What to do if you smell gas DO NOT try to light any appliance DO NOT touch any electrical switch DO NOT use any phone in your b...

Страница 2: ...Pressure Pression xx x in w c Po Col D eau Maximum Manifold Pressure Pression x x in w c Po Col d eau Minimum Manifold Pressure Pression x x in w c Po Col d eau Minimum rate with variable regulator on...

Страница 3: ...Tasks 14 B Maintenance Tasks Homeowner 14 C Maintenance Tasks Qualified Service Technician 16 5 Frequently Asked Questions and Troubleshooting A Frequently Asked Questions 17 B Troubleshooting 18 6 R...

Страница 4: ...te of Product shipment from HHT regardless of the installation or occupancy date The term Lifetime in the table below is defined as 20 years from the beginning date of warranty coverage for gas applia...

Страница 5: ...or handling devices such as exhaust fans or forced air furnaces or other such causes 6 use of fuels other than those specified in the operation instructions 7 installation or use of components not su...

Страница 6: ...ed as primary heat in residential heating calculations NOTICE This installation must conform with local codes In the absence of local codes you must comply with the National Fuel Gas Code ANSI Z223 1...

Страница 7: ...er is not present or help is needed to properly install one Consider not using the fireplace when children will be present Contact your dealer for more information or visit www hpba org Product Info F...

Страница 8: ...CEILING 42 in 12 in 123 F 115 F 120 F 132 F 145 F 170 F 180 F APPLIANCE FRONT APPLIANCE OPENING 110 F NOTICE Surface temperatures listed above are taken with a temperature measuring probe as prescribe...

Страница 9: ...urer and from model to model actual TV temperatures should be validated at the time of each installation TVs should not be used in situations where the actual TV temperature exceeds the manufacturers...

Страница 10: ...all shipping materials have been removed from inside and or underneath the firebox Review proper placement of logs ember material and or other decorative materials Check the wiring Check the air shutt...

Страница 11: ...e person Immediately call your gas supplier from a neighbor s phone Follow the gas sup plier s instructions If you cannot reach your gas supplier call the fire department C Use only your hand to push...

Страница 12: ...while using electrical power to operate the fireplace Remove batteries from battery tray when power has been restored To Operate Fireplace Using Battery Power DC 1 Access the control cavity of the ap...

Страница 13: ...nic system The term Intermittent is used because the pilot burner flame is only present when the main burner is operating When the main burner is off the pilot is also off NOTICE Batteries should not...

Страница 14: ...ace shall be turned off and cooled before servicing When properly maintained your fireplace will give you many years of trouble free service Contact your dealer to answer questions regarding proper op...

Страница 15: ...prevent unin tended operation Remove batteries from remote controls Unplug 3 volt adapter plug on IPI models Clean glass with a non abrasive non ammonia based commercially available gas fireplace gla...

Страница 16: ...should be avoided Remove all foreign objects Verify unobstructed air circulation Figure 4 2 IPI Pilot Flame Pattern Pilot and Burner Ignition and Operation Frequency Annually By Qualified Service Tech...

Страница 17: ...eral hours This is caused by the curing of the paint and the burning off of any oils remaining from manufacturing Odor may also be released from finishing materials and adhesives used around the firep...

Страница 18: ...dule is fine Inspect pilot assembly for shorted sparker wire or cracked insulator around electrode Replace pilot if necessary 2 Pilot won t light there is no noise or spark A No power or transformer i...

Страница 19: ...gnition Verify cor rect pilot orifice is installed and gas inlet is set to pressure specifications Polish flame sensing rod with fine steel wool to remove any contaminants that may have accumulated on...

Страница 20: ...d accessories could result in a safety hazard and will void the warranty Decorative Doors and Fronts WARNING Risk of Fire Install ONLY doors or fronts approved by Hearth Home Technologies Unapproved d...

Страница 21: ...ice Parts Beginning Manufacturing Date Feb 2016 Ending Manufacturing Date Active Manufacturing Reactivation Date May 2022 NDV3630I B NDV3933I B NDV4236I B NDV4842I B NDV4236I NVR Novus Gas Fireplace D...

Страница 22: ...order overlay CUST4018 001 4055 194 9 4055 133 10 Glass Latch Assembly Qty 4 req 2382 400 Y 11 Dry Wall Lip 4031 205 12 Exhaust Baffle 2382 129 13 Glass Shield 4031 217 14 Hearth Pan 2380 111 15 Burn...

Страница 23: ...order overlay CUST4018 001 4055 195 9 4055 133 10 Glass Latch Assembly Qty 4 req 2382 400 Y 11 Dry Wall Lip 4031 206 12 Exhaust Baffle 2382 129 13 Glass Shield 4031 218 14 Hearth Pan 2381 111 15 Burn...

Страница 24: ...tch Assembly Qty 4 req 2382 400 Y 11 Dry Wall Lip 4031 207 12 Exhaust Baffle 2382 129 13 Glass Shield 4031 219 14 Hearth Pan 2382 111 15 Burner Assembly 2382 007 Y 16 Valve Assembly Refer to valve pag...

Страница 25: ...t order overlay CUST4018 001 4055 197 9 4055 133 10 Glass Latch Assembly Qty 4 req 2382 400 Y 11 Dry Wall Lip 4031 208 12 Exhaust Shield 2382 129 13 Glass Shield 4031 220 14 Hearth Pan 2383 111 15 Bur...

Страница 26: ...y 2382 584 16 7 Valve Bracket 4055 205 16 8 Valve NG 750 500 Y Valve Propane 2155 501 Y 16 9 Brass Fitting Pkg of 5 303 315 5 Y 16 10 3 Volt Transformer SRV593 593 Y 16 11 Module 593 592 Y 16 12 Modul...

Страница 27: ...________________________________________________________________________________ ________________________________________________________________________________ ______________________________________...

Отзывы: