With proper installation, operation, and maintenance your gas appliance will provide years of trouble-free service.  If you do 

experience a problem, this troubleshooting guide will assist a qualified service technician in the diagnosis of a problem and 

the corrective action to be taken. This troubleshooting guide can only be used by a qualified service technician.  Contact 

your dealer to arrange a service call by a qualified service technician.

B. Troubleshooting

Intellifire Ignition System

Symptom

Possible Cause

Corrective Action

1. Pilot won’t light. 

The ignitor/module 

makes noise, but no 

spark.

A.  Incorrect wiring.

Verify “S” wire (white) for sensor and “I” wire (orange) for ignitor are 

connected to correct terminals on module and pilot assembly.

B.  Loose connections or electrical 

shorts in the wiring.

Verify no loose connections or electrical shorts in wiring from mod-

ule to pilot assembly. Verify connections underneath pilot assem-

bly are tight; also verify connections are not grounding out to metal 

chassis, pilot burner, pilot enclosure, mesh screen if present, or any 

other metal object. 

C.  Ignitor gap is too large.

Verify gap of igniter to right side of pilot hood. The gap should be 

approximately  .095 in. (2.41 mm) to .135 in. (3.43 mm).

D.  Module.

Turn ON/OFF rocker switch or wall switch to OFF position. Remove 

ignitor wire “I” from module. Place a grounded wire about 3/16 in. (5 

mm) away from “I” terminal on module. Place ON/OFF rocker switch 

or wall switch in ON position. If there is no spark at “I” terminal module 

must be replaced. If there is a spark at “I” terminal, module is fine. 

Inspect pilot assembly for shorted sparker wire or cracked insulator 

around electrode. Replace pilot if necessary.

2. Pilot won’t light, 

there is no noise or 

spark.

A.  No power or transformer installed 

incorrectly.

Verify that transformer is installed and plugged into module. Check 

voltage of transformer under load at spade connection on module 

with ON/OFF switch in ON position. Acceptable readings of a good 

transformer are between 3.2 and 2.8 volts AC.

B.  A shorted or loose connection in 

wiring configuration or wiring har

-

ness.

Remove and reinstall the wiring harness that plugs into module. 

Verify there is a tight fit. Verify pilot assembly wiring to module. Re

-

move and verify continuity of each wire in wiring harness.  Replace 

any damaged components.

C.  Improper wall switch wiring.

Verify that 110-120 VAC power is “ON” to junction box.

D.  Module not grounded.

Verify black ground wire from module wire harness is grounded to 

metal chassis of appliance.

E.  Module.

Turn ON/OFF rocker switch or wall switch to OFF position. Remove 

ignitor  wire  “I”  from  module.  Place  ON/OFF  rocker  switch  or  wall 

switch  in  ON  position.  If  there  is  no  spark  at  “I”  terminal  module 

must be replaced. If there is a spark at “I” terminal, module is fine. 

Inspect pilot assembly for shorted sparker wire or cracked insulator 

around electrode.

3. Pilot sparks, but 

Pilot will not light.

A.  Gas supply.

Verify that incoming gas line  ball valve is “open”. Verify that inlet 

pressure reading is within acceptable limits.

B.  Ignitor gap is too large.

Verify gap of igniter to right side of pilot hood. The gap should be 

approximately  .095 in. (2.41 mm) to .135 in. (3.43 mm).

C.  Module is not grounded.

Verify module is securely grounded to metal chassis of appliance.

D.  Module voltage output / Valve/Pilot 

solenoid ohms readings.

Verify battery voltage is at least 2.7 volts. Replace batteries if volt-

age is below 2.7.

Содержание NDV3630I-B

Страница 1: ...mable vapors and liquids in the vicinity of this or any other appliance What to do if you smell gas DO NOT try to light any appliance DO NOT touch any electrical switch DO NOT use any phone in your b...

Страница 2: ...Pressure Pression xx x in w c Po Col D eau Maximum Manifold Pressure Pression x x in w c Po Col d eau Minimum Manifold Pressure Pression x x in w c Po Col d eau Minimum rate with variable regulator on...

Страница 3: ...Tasks 14 B Maintenance Tasks Homeowner 14 C Maintenance Tasks Qualified Service Technician 16 5 Frequently Asked Questions and Troubleshooting A Frequently Asked Questions 17 B Troubleshooting 18 6 R...

Страница 4: ...te of Product shipment from HHT regardless of the installation or occupancy date The term Lifetime in the table below is defined as 20 years from the beginning date of warranty coverage for gas applia...

Страница 5: ...or handling devices such as exhaust fans or forced air furnaces or other such causes 6 use of fuels other than those specified in the operation instructions 7 installation or use of components not su...

Страница 6: ...ed as primary heat in residential heating calculations NOTICE This installation must conform with local codes In the absence of local codes you must comply with the National Fuel Gas Code ANSI Z223 1...

Страница 7: ...er is not present or help is needed to properly install one Consider not using the fireplace when children will be present Contact your dealer for more information or visit www hpba org Product Info F...

Страница 8: ...CEILING 42 in 12 in 123 F 115 F 120 F 132 F 145 F 170 F 180 F APPLIANCE FRONT APPLIANCE OPENING 110 F NOTICE Surface temperatures listed above are taken with a temperature measuring probe as prescribe...

Страница 9: ...urer and from model to model actual TV temperatures should be validated at the time of each installation TVs should not be used in situations where the actual TV temperature exceeds the manufacturers...

Страница 10: ...all shipping materials have been removed from inside and or underneath the firebox Review proper placement of logs ember material and or other decorative materials Check the wiring Check the air shutt...

Страница 11: ...e person Immediately call your gas supplier from a neighbor s phone Follow the gas sup plier s instructions If you cannot reach your gas supplier call the fire department C Use only your hand to push...

Страница 12: ...while using electrical power to operate the fireplace Remove batteries from battery tray when power has been restored To Operate Fireplace Using Battery Power DC 1 Access the control cavity of the ap...

Страница 13: ...nic system The term Intermittent is used because the pilot burner flame is only present when the main burner is operating When the main burner is off the pilot is also off NOTICE Batteries should not...

Страница 14: ...ace shall be turned off and cooled before servicing When properly maintained your fireplace will give you many years of trouble free service Contact your dealer to answer questions regarding proper op...

Страница 15: ...prevent unin tended operation Remove batteries from remote controls Unplug 3 volt adapter plug on IPI models Clean glass with a non abrasive non ammonia based commercially available gas fireplace gla...

Страница 16: ...should be avoided Remove all foreign objects Verify unobstructed air circulation Figure 4 2 IPI Pilot Flame Pattern Pilot and Burner Ignition and Operation Frequency Annually By Qualified Service Tech...

Страница 17: ...eral hours This is caused by the curing of the paint and the burning off of any oils remaining from manufacturing Odor may also be released from finishing materials and adhesives used around the firep...

Страница 18: ...dule is fine Inspect pilot assembly for shorted sparker wire or cracked insulator around electrode Replace pilot if necessary 2 Pilot won t light there is no noise or spark A No power or transformer i...

Страница 19: ...gnition Verify cor rect pilot orifice is installed and gas inlet is set to pressure specifications Polish flame sensing rod with fine steel wool to remove any contaminants that may have accumulated on...

Страница 20: ...d accessories could result in a safety hazard and will void the warranty Decorative Doors and Fronts WARNING Risk of Fire Install ONLY doors or fronts approved by Hearth Home Technologies Unapproved d...

Страница 21: ...ice Parts Beginning Manufacturing Date Feb 2016 Ending Manufacturing Date Active Manufacturing Reactivation Date May 2022 NDV3630I B NDV3933I B NDV4236I B NDV4842I B NDV4236I NVR Novus Gas Fireplace D...

Страница 22: ...order overlay CUST4018 001 4055 194 9 4055 133 10 Glass Latch Assembly Qty 4 req 2382 400 Y 11 Dry Wall Lip 4031 205 12 Exhaust Baffle 2382 129 13 Glass Shield 4031 217 14 Hearth Pan 2380 111 15 Burn...

Страница 23: ...order overlay CUST4018 001 4055 195 9 4055 133 10 Glass Latch Assembly Qty 4 req 2382 400 Y 11 Dry Wall Lip 4031 206 12 Exhaust Baffle 2382 129 13 Glass Shield 4031 218 14 Hearth Pan 2381 111 15 Burn...

Страница 24: ...tch Assembly Qty 4 req 2382 400 Y 11 Dry Wall Lip 4031 207 12 Exhaust Baffle 2382 129 13 Glass Shield 4031 219 14 Hearth Pan 2382 111 15 Burner Assembly 2382 007 Y 16 Valve Assembly Refer to valve pag...

Страница 25: ...t order overlay CUST4018 001 4055 197 9 4055 133 10 Glass Latch Assembly Qty 4 req 2382 400 Y 11 Dry Wall Lip 4031 208 12 Exhaust Shield 2382 129 13 Glass Shield 4031 220 14 Hearth Pan 2383 111 15 Bur...

Страница 26: ...y 2382 584 16 7 Valve Bracket 4055 205 16 8 Valve NG 750 500 Y Valve Propane 2155 501 Y 16 9 Brass Fitting Pkg of 5 303 315 5 Y 16 10 3 Volt Transformer SRV593 593 Y 16 11 Module 593 592 Y 16 12 Modul...

Страница 27: ...________________________________________________________________________________ ________________________________________________________________________________ ______________________________________...

Отзывы: