Symptom

Possible Cause

Corrective Action

4. Pilot lights but contin-

ues to spark, and main 

burner will not ignite. 

(If the pilot continues 

to spark after the 

pilot flame has been lit, 

flame rectification has 

not occurred.)

A.  A shorted or loose connection in flame 

sensing rod.

Verify all connections to wiring diagram in manual. Verify 

connections underneath pilot assembly are tight. Verify con-

nections are not grounding out to metal chassis, pilot burn-

er, pilot enclosure or screen if present, or any other metal 

object.

B.  Poor flame rectification or contaminated 

flame sensing rod. 

With fixed glass assembly in place, verify that flame is en

-

gulfing flame sensing rod on left side of pilot hood.  Flame 

sensing rod

 

should glow shortly after ignition.  Verify cor-

rect pilot orifice is installed and gas inlet is set to pressure 

specifications. Polish flame sensing rod with fine steel wool 

to remove any contaminants that may have accumulated on 

flame sensing rod.

C.  Module is not grounded.

Verify module is securely grounded to metal chassis of ap-

pliance.  Verify that wire harness is firmly connected to the 

module.

D.  Damaged pilot assembly or contami-

nated flame sensing rod.

Verify that ceramic insulator around the flame sensing rod 

is not cracked, damaged, or loose. Verify connection from 

flame sensing rod to white sensor wire. Polish flame sens

-

ing  rod  with  fine  steel  wool  to  remove  any  contaminants 

that  may  have  accumulated  on  flame  sensing  rod.  Verify 

continuity with a multimeter with ohms set at lowest range. 

Replace pilot if any damage is detected.  

E.  Module.

Turn ON/OFF rocker switch or wall switch to OFF position. 

Remove ignitor wire “I” from module. Place ON/OFF rocker 

switch or wall switch in ON position. If there is no spark at “I” 

terminal module must be replaced. If there is a spark at “I” 

terminal, module is fine. 

Содержание NDV3630I-B

Страница 1: ...mable vapors and liquids in the vicinity of this or any other appliance What to do if you smell gas DO NOT try to light any appliance DO NOT touch any electrical switch DO NOT use any phone in your b...

Страница 2: ...Pressure Pression xx x in w c Po Col D eau Maximum Manifold Pressure Pression x x in w c Po Col d eau Minimum Manifold Pressure Pression x x in w c Po Col d eau Minimum rate with variable regulator on...

Страница 3: ...Tasks 14 B Maintenance Tasks Homeowner 14 C Maintenance Tasks Qualified Service Technician 16 5 Frequently Asked Questions and Troubleshooting A Frequently Asked Questions 17 B Troubleshooting 18 6 R...

Страница 4: ...te of Product shipment from HHT regardless of the installation or occupancy date The term Lifetime in the table below is defined as 20 years from the beginning date of warranty coverage for gas applia...

Страница 5: ...or handling devices such as exhaust fans or forced air furnaces or other such causes 6 use of fuels other than those specified in the operation instructions 7 installation or use of components not su...

Страница 6: ...ed as primary heat in residential heating calculations NOTICE This installation must conform with local codes In the absence of local codes you must comply with the National Fuel Gas Code ANSI Z223 1...

Страница 7: ...er is not present or help is needed to properly install one Consider not using the fireplace when children will be present Contact your dealer for more information or visit www hpba org Product Info F...

Страница 8: ...CEILING 42 in 12 in 123 F 115 F 120 F 132 F 145 F 170 F 180 F APPLIANCE FRONT APPLIANCE OPENING 110 F NOTICE Surface temperatures listed above are taken with a temperature measuring probe as prescribe...

Страница 9: ...urer and from model to model actual TV temperatures should be validated at the time of each installation TVs should not be used in situations where the actual TV temperature exceeds the manufacturers...

Страница 10: ...all shipping materials have been removed from inside and or underneath the firebox Review proper placement of logs ember material and or other decorative materials Check the wiring Check the air shutt...

Страница 11: ...e person Immediately call your gas supplier from a neighbor s phone Follow the gas sup plier s instructions If you cannot reach your gas supplier call the fire department C Use only your hand to push...

Страница 12: ...while using electrical power to operate the fireplace Remove batteries from battery tray when power has been restored To Operate Fireplace Using Battery Power DC 1 Access the control cavity of the ap...

Страница 13: ...nic system The term Intermittent is used because the pilot burner flame is only present when the main burner is operating When the main burner is off the pilot is also off NOTICE Batteries should not...

Страница 14: ...ace shall be turned off and cooled before servicing When properly maintained your fireplace will give you many years of trouble free service Contact your dealer to answer questions regarding proper op...

Страница 15: ...prevent unin tended operation Remove batteries from remote controls Unplug 3 volt adapter plug on IPI models Clean glass with a non abrasive non ammonia based commercially available gas fireplace gla...

Страница 16: ...should be avoided Remove all foreign objects Verify unobstructed air circulation Figure 4 2 IPI Pilot Flame Pattern Pilot and Burner Ignition and Operation Frequency Annually By Qualified Service Tech...

Страница 17: ...eral hours This is caused by the curing of the paint and the burning off of any oils remaining from manufacturing Odor may also be released from finishing materials and adhesives used around the firep...

Страница 18: ...dule is fine Inspect pilot assembly for shorted sparker wire or cracked insulator around electrode Replace pilot if necessary 2 Pilot won t light there is no noise or spark A No power or transformer i...

Страница 19: ...gnition Verify cor rect pilot orifice is installed and gas inlet is set to pressure specifications Polish flame sensing rod with fine steel wool to remove any contaminants that may have accumulated on...

Страница 20: ...d accessories could result in a safety hazard and will void the warranty Decorative Doors and Fronts WARNING Risk of Fire Install ONLY doors or fronts approved by Hearth Home Technologies Unapproved d...

Страница 21: ...ice Parts Beginning Manufacturing Date Feb 2016 Ending Manufacturing Date Active Manufacturing Reactivation Date May 2022 NDV3630I B NDV3933I B NDV4236I B NDV4842I B NDV4236I NVR Novus Gas Fireplace D...

Страница 22: ...order overlay CUST4018 001 4055 194 9 4055 133 10 Glass Latch Assembly Qty 4 req 2382 400 Y 11 Dry Wall Lip 4031 205 12 Exhaust Baffle 2382 129 13 Glass Shield 4031 217 14 Hearth Pan 2380 111 15 Burn...

Страница 23: ...order overlay CUST4018 001 4055 195 9 4055 133 10 Glass Latch Assembly Qty 4 req 2382 400 Y 11 Dry Wall Lip 4031 206 12 Exhaust Baffle 2382 129 13 Glass Shield 4031 218 14 Hearth Pan 2381 111 15 Burn...

Страница 24: ...tch Assembly Qty 4 req 2382 400 Y 11 Dry Wall Lip 4031 207 12 Exhaust Baffle 2382 129 13 Glass Shield 4031 219 14 Hearth Pan 2382 111 15 Burner Assembly 2382 007 Y 16 Valve Assembly Refer to valve pag...

Страница 25: ...t order overlay CUST4018 001 4055 197 9 4055 133 10 Glass Latch Assembly Qty 4 req 2382 400 Y 11 Dry Wall Lip 4031 208 12 Exhaust Shield 2382 129 13 Glass Shield 4031 220 14 Hearth Pan 2383 111 15 Bur...

Страница 26: ...y 2382 584 16 7 Valve Bracket 4055 205 16 8 Valve NG 750 500 Y Valve Propane 2155 501 Y 16 9 Brass Fitting Pkg of 5 303 315 5 Y 16 10 3 Volt Transformer SRV593 593 Y 16 11 Module 593 592 Y 16 12 Modul...

Страница 27: ...________________________________________________________________________________ ________________________________________________________________________________ ______________________________________...

Отзывы: