Heatilator  •  NBV30-IFT, NBV33-IFT, NBV36-IFT, NBV42-IFT Owner’s Manual  •  2624-981 Rev. C 

 

•  8/20      

Figure 3.4  Good Faith TV Guidelines

Good Faith Guidelines for TV Installa ons above a Typical Gas Fireplace  

 

 

Item  Minimum Dimensions

2.5 inches

2 inches minimum to 3 inches 

maximum 

18 inches

Wall Brkt + TV Thi 2.5 

inches 

B

B

Fireplace 

TV 

Mantel 

Notes: 

1. These are good faith recommended clearances only and not a guarantee of compliance with all TV 

manufacturers’ maximum allowable opera ng temperatures.    

2. Since every home has unique air 

fl

ow characteris cs and maximum allowable opera ng temperatures 

can vary from manufacturer to manufacturer and from model to model, actual TV temperatures should 

be validated at the  me of each installa on.  TVs should not be used in situa ons where the actual TV 

temperature exceeds the manufacturers’ maximum allowable opera ng temperatures iden

fi

ed in the 

TV’s technical speci

fi

ca ons. Contact the TV’s manufacturer directly if you cannot locate this 

informa on or have ques ons regarding the informa on. 

3. Mantel height and depth must conform to mantle requirements 

specifi

ed in the 

fi

replace installa on 

manual. 

4.

“C” dimension taken from the top of the hood or 

firepl

ace opening.

 

5.

Sugges ons on how to further reduce TV temperatures:

 

a. Increase “A” dimension. 

b.

Increase “C” dimension, however, increasing “B” dimension beyond maximum recommended 

typically results in higher temperatures.

 

TV Wall 

Bracket 

Fireplace 

C

TV on the wall

TV recessed into the wall

Содержание NBV30-IFT

Страница 1: ...call your gas supplier from a neighbor s phone Follow the gas sup plier s instructions If you cannot reach your gas supplier call the fire department Installation and service must be performed by a q...

Страница 2: ...Pression xx x in w c Po Col D eau Maximum Manifold Pressure Pression x x in w c Po Col d eau Minimum Manifold Pressure Pression x x in w c Po Col d eau Minimum rate with variable regulator on control...

Страница 3: ...pecific Information A Appliance Certification 6 B Glass Specifications 6 C BTU Specifications 6 3 Important Safety and Operating Information A Appliance Safety 7 B General Operating Parts 8 C Fuel Spe...

Страница 4: ...ler distributor whichever occurs earlier However the warranty shall commence no later than 24 months following the date of product shipment from HHT regardless of the installation or occupancy date Th...

Страница 5: ...or improper handling 4 improper operation abuse misuse continued operation with damaged corroded or failed components accident or improperly incorrectly performed repairs 5 environmental conditions i...

Страница 6: ...eat in residential heating calculations 2 2 Product Specific Information This product is listed to ANSI standards for Vented Gas Fireplaces May be installed in a sleeping room when the provisions for...

Страница 7: ...l gas and the products of combustion of such fuels can expose you to chemicals including benzene which is known to the State of California to cause cancer and reproductive harm For more information go...

Страница 8: ...emperatures above the center of the appliance at various heights above the appliance opening NOTICE Surface temperatures listed above are taken with a temperature measuring probe as prescribed by the...

Страница 9: ...turer and from model to model actual TV temperatures should be validated at the me of each installa on TVs should not be used in situa ons where the actual TV temperature exceeds the manufacturers max...

Страница 10: ...ol handle is HOT when fireplace is in operation Adjust BEFORE lighting fire F Before Lighting Appliance Before operating this fireplace for the first time it is rec ommended that a qualified service t...

Страница 11: ...e gas sup plier s instructions C Use only your hand to push in or turn the gas control knob Never use tools If the knob will not push in or turn by hand DO NOT D DO NOT use this appliance if any part...

Страница 12: ...t away Optional Heat Out Gas Kit The Heat Out Gas heat management option is available for use with the NBV IFT appliances and must be used in conjunction with the IFT RC400 control The Heat Out Gas ki...

Страница 13: ...N Position The appliance will ignite and run continuously at the HI flame setting No adjustment in flame height is possible Remote Position The remote position allows operation of the appliance from a...

Страница 14: ...ch to start the appliance appliance will ignite normally if the error condition was corrected If the IFT ECM re enters the lock out condition after these steps call your dealer for service Appliance O...

Страница 15: ...l be turned off and cooled before servicing When properly maintained your fireplace will give you many years of trouble free service Contact your dealer to answer questions regarding proper operation...

Страница 16: ...event unin tended operation Remove batteries from remote controls Unplug the 6 volt adapter plug Clean glass with a non abrasive non ammonia based commercially available gas fireplace glass cleaner Li...

Страница 17: ...ve penetrated the sheet metal are sharp and should be avoided Remove all foreign objects Verify unobstructed air circulation Figure 4 2 IPI Pilot Flame Pattern Pilot and Burner Ignition and Operation...

Страница 18: ...g from manufacturing Odor may also be released from finishing materials and adhesives used around the fireplace These circumstances may require additional curing related to the installation environmen...

Страница 19: ...e intensity based on the difference between the desired room temperature and actual temperature In thermostat mode the hearth appliance will start in HI flame but as the actual temperature approaches...

Страница 20: ...OFF position Verify IFT ECM slider switch is in ON or REM position Verify AC power available to junction box Verify AC DC adaptor is plugged into junction box and ECM Verify AC DC adaptor out put volt...

Страница 21: ...s connected to brown and black wire in 6 pin valve wire harness Check if pressure switch is closed shorted when PV blower is running Refer to PV troubleshooting instructions Appliance lights and runs...

Страница 22: ...3 J After a qualified service technician has installed the heat management system follow the instruction supplied with the kit for operation Contact your dealer if you have questions Optional Refracto...

Страница 23: ...8 20 B Service Parts Service Parts Beginning Manufacturing Date Sept 2020 Ending Manufacturing Date Active 1 2 3 4 5 Part number list on following page Log Set Assembly Novus Gas Fireplace BV 08 20 N...

Страница 24: ...4031 217 10 Glass Latch Assembly Qty 4 req 2382 400 Y 11 Hearth Pan 2380 111 12 Burner Assembly 2380 007 Y 13 Valve Assembly Refer to valve page 14 Gasket Valve Plate Qty 2 req 4055 135 15 Glass Frame...

Страница 25: ...4031 218 10 Glass Latch Assembly Qty 4 req 2382 400 Y 11 Hearth Pan 2381 111 12 Burner Assembly 2381 007 Y 13 Valve Assembly Refer to valve page 14 Gasket Valve Plate Qty 2 req 4055 135 15 Glass Frame...

Страница 26: ...4031 219 10 Glass Latch Assembly Qty 4 req 2382 400 Y 11 Hearth Pan 2382 111 12 Burner Assembly 2382 007 Y 13 Valve Assembly Refer to valve page 14 Gasket Valve Plate Qty 2 req 4055 135 15 Glass Frame...

Страница 27: ...4031 220 10 Glass Latch Assembly Qty 4 req 2382 400 Y 11 Hearth Pan 2383 111 12 Burner Assembly 2383 007 Y 13 Valve Assembly Refer to valve page 14 Gasket Valve Plate Qty 2 req 4055 135 15 Glass Fram...

Страница 28: ...Y 13 7 Valve NG SRV2166 302 Y Valve Propane 2166 303 Y 13 8 Brass Fitting Pkg of 5 303 315 5 Y 13 9 Wire Harness IFT 6 Pin SRV2326 132 Y 13 10 Jumper Wire 2155 003 Y 13 11 Module IFT Control SRV2326 1...