Frequently Asked Questions and Troubleshooting 

A.  Frequently Asked Questions

Contact your dealer

 for additional information regarding operation and troubleshooting.  Visit www.heatilator.com to 

locate a dealer.

ISSUE

SOLUTIONS

 Condensation on the glass

This is a result of gas combustion and temperature variations. Prior to appliance being turned 

on, the inside of the glass has cooled below the dew point producing a byproduct of combus-

tion:  water in the form of condensation.  As the fireplace glass warms, the condensation will 

disappear. 

 

In the summer, the inside of your fireplace contains hot humid air from outdoors. When the air 

from outdoors contacts glass cooled below the dew point by your air conditioning, moisture in 

that air will condense.

 Blue flames

This is a result of normal operation and the flames will begin to yellow as the fireplace is 

allowed to burn for 20 to 40 minutes.

 Erratic flames

Verify that the glass assembly is correctly installed and that all glass latches are engaged over 

the tabs on the glass frame.

 Odor from fireplace

When first operated, this fireplace may release an odor for the first several hours. This is caused 

by the curing of the paint and the burning off of any oils remaining from manufacturing. Odor 

may also be released from finishing materials and adhesives used around the fireplace.  These 

circumstances may require additional curing related to the installation environment.

 Film on the glass

This is a normal result of the curing process of the paint and logs. Glass should be cleaned 

within 3 to 4 hours of initial burning to remove deposits left by oils from the manufacturing pro-

cess. A non-abrasive cleaner such as gas fireplace glass cleaner may be necessary. 

Contact

 

your dealer.

 Metallic noise

Noise is caused by metal expanding and contracting as it heats up and cools down, similar to 

the sound produced by a furnace or heating duct. This noise does not affect the operation or 

longevity of the fireplace.

Is it normal to see the pilot flame burn  

continually?

In an intermittent pilot ignition system (IPI), the pilot flame should turn off when appliance is 

turned off. Some optional control systems available with IPI models may allow pilot flame to 

remain lit.

Power Outages

(battery backup)

NBV-IFT appliances are not approved for use with battery backup. 

 

Do NOT operate 

this appliance with battery backup.  This appliance will not be protected by the high 

temp limit switch if battery backup is installed.  

Refer to Section 3 for more details.

Wall above appliance feels hot to   

 the touch.

No action necessary.  This appliance ships with a non-combustible material attached. Speci-

fications of the attached non-combustible material are listed in the Installer’s Manual for this 

appliance.

Содержание NBV30-IFT

Страница 1: ...call your gas supplier from a neighbor s phone Follow the gas sup plier s instructions If you cannot reach your gas supplier call the fire department Installation and service must be performed by a q...

Страница 2: ...Pression xx x in w c Po Col D eau Maximum Manifold Pressure Pression x x in w c Po Col d eau Minimum Manifold Pressure Pression x x in w c Po Col d eau Minimum rate with variable regulator on control...

Страница 3: ...pecific Information A Appliance Certification 6 B Glass Specifications 6 C BTU Specifications 6 3 Important Safety and Operating Information A Appliance Safety 7 B General Operating Parts 8 C Fuel Spe...

Страница 4: ...ler distributor whichever occurs earlier However the warranty shall commence no later than 24 months following the date of product shipment from HHT regardless of the installation or occupancy date Th...

Страница 5: ...or improper handling 4 improper operation abuse misuse continued operation with damaged corroded or failed components accident or improperly incorrectly performed repairs 5 environmental conditions i...

Страница 6: ...eat in residential heating calculations 2 2 Product Specific Information This product is listed to ANSI standards for Vented Gas Fireplaces May be installed in a sleeping room when the provisions for...

Страница 7: ...l gas and the products of combustion of such fuels can expose you to chemicals including benzene which is known to the State of California to cause cancer and reproductive harm For more information go...

Страница 8: ...emperatures above the center of the appliance at various heights above the appliance opening NOTICE Surface temperatures listed above are taken with a temperature measuring probe as prescribed by the...

Страница 9: ...turer and from model to model actual TV temperatures should be validated at the me of each installa on TVs should not be used in situa ons where the actual TV temperature exceeds the manufacturers max...

Страница 10: ...ol handle is HOT when fireplace is in operation Adjust BEFORE lighting fire F Before Lighting Appliance Before operating this fireplace for the first time it is rec ommended that a qualified service t...

Страница 11: ...e gas sup plier s instructions C Use only your hand to push in or turn the gas control knob Never use tools If the knob will not push in or turn by hand DO NOT D DO NOT use this appliance if any part...

Страница 12: ...t away Optional Heat Out Gas Kit The Heat Out Gas heat management option is available for use with the NBV IFT appliances and must be used in conjunction with the IFT RC400 control The Heat Out Gas ki...

Страница 13: ...N Position The appliance will ignite and run continuously at the HI flame setting No adjustment in flame height is possible Remote Position The remote position allows operation of the appliance from a...

Страница 14: ...ch to start the appliance appliance will ignite normally if the error condition was corrected If the IFT ECM re enters the lock out condition after these steps call your dealer for service Appliance O...

Страница 15: ...l be turned off and cooled before servicing When properly maintained your fireplace will give you many years of trouble free service Contact your dealer to answer questions regarding proper operation...

Страница 16: ...event unin tended operation Remove batteries from remote controls Unplug the 6 volt adapter plug Clean glass with a non abrasive non ammonia based commercially available gas fireplace glass cleaner Li...

Страница 17: ...ve penetrated the sheet metal are sharp and should be avoided Remove all foreign objects Verify unobstructed air circulation Figure 4 2 IPI Pilot Flame Pattern Pilot and Burner Ignition and Operation...

Страница 18: ...g from manufacturing Odor may also be released from finishing materials and adhesives used around the fireplace These circumstances may require additional curing related to the installation environmen...

Страница 19: ...e intensity based on the difference between the desired room temperature and actual temperature In thermostat mode the hearth appliance will start in HI flame but as the actual temperature approaches...

Страница 20: ...OFF position Verify IFT ECM slider switch is in ON or REM position Verify AC power available to junction box Verify AC DC adaptor is plugged into junction box and ECM Verify AC DC adaptor out put volt...

Страница 21: ...s connected to brown and black wire in 6 pin valve wire harness Check if pressure switch is closed shorted when PV blower is running Refer to PV troubleshooting instructions Appliance lights and runs...

Страница 22: ...3 J After a qualified service technician has installed the heat management system follow the instruction supplied with the kit for operation Contact your dealer if you have questions Optional Refracto...

Страница 23: ...8 20 B Service Parts Service Parts Beginning Manufacturing Date Sept 2020 Ending Manufacturing Date Active 1 2 3 4 5 Part number list on following page Log Set Assembly Novus Gas Fireplace BV 08 20 N...

Страница 24: ...4031 217 10 Glass Latch Assembly Qty 4 req 2382 400 Y 11 Hearth Pan 2380 111 12 Burner Assembly 2380 007 Y 13 Valve Assembly Refer to valve page 14 Gasket Valve Plate Qty 2 req 4055 135 15 Glass Frame...

Страница 25: ...4031 218 10 Glass Latch Assembly Qty 4 req 2382 400 Y 11 Hearth Pan 2381 111 12 Burner Assembly 2381 007 Y 13 Valve Assembly Refer to valve page 14 Gasket Valve Plate Qty 2 req 4055 135 15 Glass Frame...

Страница 26: ...4031 219 10 Glass Latch Assembly Qty 4 req 2382 400 Y 11 Hearth Pan 2382 111 12 Burner Assembly 2382 007 Y 13 Valve Assembly Refer to valve page 14 Gasket Valve Plate Qty 2 req 4055 135 15 Glass Frame...

Страница 27: ...4031 220 10 Glass Latch Assembly Qty 4 req 2382 400 Y 11 Hearth Pan 2383 111 12 Burner Assembly 2383 007 Y 13 Valve Assembly Refer to valve page 14 Gasket Valve Plate Qty 2 req 4055 135 15 Glass Fram...

Страница 28: ...Y 13 7 Valve NG SRV2166 302 Y Valve Propane 2166 303 Y 13 8 Brass Fitting Pkg of 5 303 315 5 Y 13 9 Wire Harness IFT 6 Pin SRV2326 132 Y 13 10 Jumper Wire 2155 003 Y 13 11 Module IFT Control SRV2326 1...

Страница 29: ...___________________________________________________ ________________________________________________________________________________ ___________________________________________________________________...

Отзывы: