Heatilator NBV30-IFT Скачать руководство пользователя страница 12

12

Heatilator  •  NBV30-IFT, NBV33-IFT, NBV36-IFT, NBV42-IFT Owner’s Manual  •  2624-981  Rev. C 

 

•  8/20  

I.  Appliance Break-In

Follow the initial break-in procedure below to cure the 

materials  used  to  manufacture  the  fireplace  and  the 

finishing materials around it.

• The fireplace should be run three to four hours 

continuously on high.  

•  Turn the fireplace off and allow it to cool completely.
•  Remove fixed glass assembly. See Section 4.B.
•  Clean fixed glass assembly. See Section 4.B.
•  Replace the fixed glass assembly and run continuously 

on high an additional 6-12 hours.  

Note: 

  Some IPI systems have a safety feature that 

automatically  shuts  down  the  fireplace  after  9  hours  of 

continuous operation without receiving a command from 

the remote control.  If this occurs, restart the appliance.

NOTICE! 

Open windows for air circulation during fire

-

place break-in.

•  Some people may be sensitive to smoke and odors.

•  Smoke detectors may activate.

Option 3:
The optional fan can be used in conjunction with awall 

mounted switch.  See Figure 8.3.  To control fan speed a 

BC10 (Blower Control Wall Switch) must be used:
•  The power supply for the appliance must be brought into 

a switch box.

•  The power can then be supplied from the switch box to 

the appliance using a minimum of 14-2 with ground wire.

•  At the switch box connect the black (hot) wire and red 

(switch leg) wire to the wall switch as shown.

•  At the appliance connect the black (hot), white (neutral) 

and green (ground) wires to the junction box as shown.

•  Add a 1/4 inch insulated female connector to the red 

(switch leg) wire, route it through the knockout in the face 

of the junction box, and connect to the top fan switch 

connector (1/4 inch male) as shown.

Optional Heat-Zone

®

-Gas Kit

The Heat-Zone

®

-Gas heat management option is avail-

able for use with the NBV-IFT appliances. The Heat-Zone 

Kit draws heat from your fireplace to an adjacent room in 

your home, up to 20 feet away.

Optional Heat-Out-Gas Kit

The Heat-Out-Gas heat management option is available 

for use with the NBV-IFT appliances and must be used 

in conjunction with the IFT-RC400 control. The Heat-

Out-Gas kit draws heat from your fireplace and directs it 

outside, up to 25 feet away.

Optional Heat-Duct Kit

The Heat-Duct heat management option is available 

for use with the NBV-IFT appliances.  The Heat-Duct 

redistributes  heat  from  the  fireplace  via  the  furnace 

ductwork. 

An optional heat management system, which allows the 

heat from the appliance to be redirected as desired, may 

be installed with this appliance.   It may be either a Heat-

Zone

®

-Gas, which diverts heat into an adjacent room, 

and/or a HEAT-OUT-GAS which will divert heat outside 

the home/building. 

Refer to Section 6 of the appliance installation manual to 

confirm which of the heat management systems may be 

installed together.  All heat management systems must be 

installed by a qualified service technician at the time of 

appliance installation. 

Optional Heat Management Systems

J.  Heat Management
Burn Rate

The NBV-IFT models have a variable burn rate which is 

controlled by a remote control.  Therefore the flame height 

is adjustable with an optional RC400 remote control. 

The flame height may be adjusted as desired by locating 

the flame option on the remote control and adjusting up or 

down to desired flame height.

K.  Operation During A Power Outage 

NBV-IFT appliances are not approved for use with battery 

backup.  

Optional Fan

A fan can be added to your appliance to push more 

warmth into your space.  
Option 1:
The optional fan can be used in conjunction with the 

optional IFT-RC400 remote control.  Fan speed is 

controlled through the remote control only.  
Option 2:
The optional fan can be used with the fan control module 

that is included in the fan kit.  Fan speed is controlled 

through the control knob on the fan control module.

WARNING! Risk of Fire or Asphyxiation! 

Do 

NOT operate this appliance with battery backup.  

This appliance will not be protected by the high temp 

limit switch if battery backup is installed.  

Содержание NBV30-IFT

Страница 1: ...call your gas supplier from a neighbor s phone Follow the gas sup plier s instructions If you cannot reach your gas supplier call the fire department Installation and service must be performed by a q...

Страница 2: ...Pression xx x in w c Po Col D eau Maximum Manifold Pressure Pression x x in w c Po Col d eau Minimum Manifold Pressure Pression x x in w c Po Col d eau Minimum rate with variable regulator on control...

Страница 3: ...pecific Information A Appliance Certification 6 B Glass Specifications 6 C BTU Specifications 6 3 Important Safety and Operating Information A Appliance Safety 7 B General Operating Parts 8 C Fuel Spe...

Страница 4: ...ler distributor whichever occurs earlier However the warranty shall commence no later than 24 months following the date of product shipment from HHT regardless of the installation or occupancy date Th...

Страница 5: ...or improper handling 4 improper operation abuse misuse continued operation with damaged corroded or failed components accident or improperly incorrectly performed repairs 5 environmental conditions i...

Страница 6: ...eat in residential heating calculations 2 2 Product Specific Information This product is listed to ANSI standards for Vented Gas Fireplaces May be installed in a sleeping room when the provisions for...

Страница 7: ...l gas and the products of combustion of such fuels can expose you to chemicals including benzene which is known to the State of California to cause cancer and reproductive harm For more information go...

Страница 8: ...emperatures above the center of the appliance at various heights above the appliance opening NOTICE Surface temperatures listed above are taken with a temperature measuring probe as prescribed by the...

Страница 9: ...turer and from model to model actual TV temperatures should be validated at the me of each installa on TVs should not be used in situa ons where the actual TV temperature exceeds the manufacturers max...

Страница 10: ...ol handle is HOT when fireplace is in operation Adjust BEFORE lighting fire F Before Lighting Appliance Before operating this fireplace for the first time it is rec ommended that a qualified service t...

Страница 11: ...e gas sup plier s instructions C Use only your hand to push in or turn the gas control knob Never use tools If the knob will not push in or turn by hand DO NOT D DO NOT use this appliance if any part...

Страница 12: ...t away Optional Heat Out Gas Kit The Heat Out Gas heat management option is available for use with the NBV IFT appliances and must be used in conjunction with the IFT RC400 control The Heat Out Gas ki...

Страница 13: ...N Position The appliance will ignite and run continuously at the HI flame setting No adjustment in flame height is possible Remote Position The remote position allows operation of the appliance from a...

Страница 14: ...ch to start the appliance appliance will ignite normally if the error condition was corrected If the IFT ECM re enters the lock out condition after these steps call your dealer for service Appliance O...

Страница 15: ...l be turned off and cooled before servicing When properly maintained your fireplace will give you many years of trouble free service Contact your dealer to answer questions regarding proper operation...

Страница 16: ...event unin tended operation Remove batteries from remote controls Unplug the 6 volt adapter plug Clean glass with a non abrasive non ammonia based commercially available gas fireplace glass cleaner Li...

Страница 17: ...ve penetrated the sheet metal are sharp and should be avoided Remove all foreign objects Verify unobstructed air circulation Figure 4 2 IPI Pilot Flame Pattern Pilot and Burner Ignition and Operation...

Страница 18: ...g from manufacturing Odor may also be released from finishing materials and adhesives used around the fireplace These circumstances may require additional curing related to the installation environmen...

Страница 19: ...e intensity based on the difference between the desired room temperature and actual temperature In thermostat mode the hearth appliance will start in HI flame but as the actual temperature approaches...

Страница 20: ...OFF position Verify IFT ECM slider switch is in ON or REM position Verify AC power available to junction box Verify AC DC adaptor is plugged into junction box and ECM Verify AC DC adaptor out put volt...

Страница 21: ...s connected to brown and black wire in 6 pin valve wire harness Check if pressure switch is closed shorted when PV blower is running Refer to PV troubleshooting instructions Appliance lights and runs...

Страница 22: ...3 J After a qualified service technician has installed the heat management system follow the instruction supplied with the kit for operation Contact your dealer if you have questions Optional Refracto...

Страница 23: ...8 20 B Service Parts Service Parts Beginning Manufacturing Date Sept 2020 Ending Manufacturing Date Active 1 2 3 4 5 Part number list on following page Log Set Assembly Novus Gas Fireplace BV 08 20 N...

Страница 24: ...4031 217 10 Glass Latch Assembly Qty 4 req 2382 400 Y 11 Hearth Pan 2380 111 12 Burner Assembly 2380 007 Y 13 Valve Assembly Refer to valve page 14 Gasket Valve Plate Qty 2 req 4055 135 15 Glass Frame...

Страница 25: ...4031 218 10 Glass Latch Assembly Qty 4 req 2382 400 Y 11 Hearth Pan 2381 111 12 Burner Assembly 2381 007 Y 13 Valve Assembly Refer to valve page 14 Gasket Valve Plate Qty 2 req 4055 135 15 Glass Frame...

Страница 26: ...4031 219 10 Glass Latch Assembly Qty 4 req 2382 400 Y 11 Hearth Pan 2382 111 12 Burner Assembly 2382 007 Y 13 Valve Assembly Refer to valve page 14 Gasket Valve Plate Qty 2 req 4055 135 15 Glass Frame...

Страница 27: ...4031 220 10 Glass Latch Assembly Qty 4 req 2382 400 Y 11 Hearth Pan 2383 111 12 Burner Assembly 2383 007 Y 13 Valve Assembly Refer to valve page 14 Gasket Valve Plate Qty 2 req 4055 135 15 Glass Fram...

Страница 28: ...Y 13 7 Valve NG SRV2166 302 Y Valve Propane 2166 303 Y 13 8 Brass Fitting Pkg of 5 303 315 5 Y 13 9 Wire Harness IFT 6 Pin SRV2326 132 Y 13 10 Jumper Wire 2155 003 Y 13 11 Module IFT Control SRV2326 1...

Страница 29: ...___________________________________________________ ________________________________________________________________________________ ___________________________________________________________________...

Отзывы: