background image

07/03

17789 Rev H

21

NA SERIES INSTALLATION INSTRUCTIONS

Figure 19 - Position the Hearth Extension

19. Position the Hearth Extension

Position  and  secure  the  hearth  extension  over  the

protective metal strips that have been placed partially

under  the  fireplace  front.  These  strips  should  be

protruding approximately 2” from under the fireplace

front  and  2”  on  both  sides  of  the  fireplace  opening.

Seal the crack between the hearth extension and

fireplace with a bead of noncombustible sealant.

See  Figure  19. Apply  a  noncombustible  finishing

material of your choice to the hearth extension.

20. Finishing Material

Do not install combustible materials over the black

face of the fireplace! This poses a safety hazard

and may start a fire. 

You may only use noncombustible

material over the black face of the fireplace.

a. Combustible Material

Material which is made of or surfaced with wood,

compressed  paper,  plant  fibers,  plastics,  or  any

material capable of igniting and burning, whether

flame proofed or not, plastered or unplastered.

b. Noncombustible Material

Material  which  will  not  ignite  and  burn.  Such

materials  are  those  consisting  entirely  of  steel,

iron, brick, tile, concrete, slate, glass or plasters,

or any combination thereof.

c. Noncombustible Sealant Material

Sealants which will not ignite and burn; General

Electric  RTV103  Black  (or  equivalent),  Rutland,

Inc. Fireplace Mortar #63 (or equivalent).
After  completing  the  framing  and  applying  the

facing material (dry wall) over the framing, a ½”

wide (maximum) bead of noncombustible sealant

must be used to close off any gaps at the top and

sides between the fireplace and facing to prevent

cold air leaks.
Only  noncombustible  materials  may  be  used  to

cover the black metal fireplace front.

21. Mantel

A combustible mantel may be positioned no lower than

12”  above  the  top  of  the  fireplace  opening.  The

combustible  mantel  may  have  a  maximum  depth  of

12”. Combustible trim pieces that project no more than

1½” from the face of the fireplace can be placed no

closer than 6” from the top of the fireplace opening.

Combustible  trim  must  not  cover  the  black  metal

surfaces of the fireplace. This mantel clearance is in

accordance with 

Section 7-3.3.3 of ANSI/NFPA211

.

22. Glass Doors

This fireplace has been tested and listed for use with

doors as specified in Section C, “System Components”.

Please  refer  to  the  manual  packed  with  each  set  of

doors for installation instructions.

Содержание NA36

Страница 1: ...42 WOODBURNING FIREPLACE WARNING Improper installation adjustment alteration service or maintenance can cause injury or property damage Refer to this manual For assistance or additional information co...

Страница 2: ...r related problems that may result from the lack of adequate combustion air It is the responsibility of the builder contractor to ensure that adequate combustion air has been provided for the fireplac...

Страница 3: ...f the home If you desire to put a fireplace in your basement we recommend that you consider a direct vent gas fireplace Basements always have a significant negative air pressure that causes the firepl...

Страница 4: ...illustrations and diagrams used throughout these installation instructions are not drawn to scale Figure 1 Typical Fireplace System B DESCRIPTION OF THE FIREPLACE SYSTEM A LISTINGS AND CODE APPROVALS...

Страница 5: ...i b a C d e h c r A 6 3 0 1 P D 2 4 0 1 P D h s i n i F k c a l B s r o o D s s a l G n o i t p e c r e P B 6 3 0 1 P D B 2 4 0 1 P D h s i n i F s s a r B d e h s i l o P s r o o D s s a l G n o i t...

Страница 6: ...6 17789 Rev H 07 03 NA SERIES INSTALLATION INSTRUCTIONS Fireplace Dimensions OUTSIDE AIR KIT AK14 NAAK14...

Страница 7: ...5 1 3 L S 5 1 n r u t e R t e s f f O y e n m i h C 0 3 3 L S A N 0 3 3 L S 0 3 n r u t e R t e s f f O y e n m i h C 8 3 3 S F A N 8 3 3 S F t h g i a r t S p o t s e r i F 9 3 3 S F 5 1 p o t s e r...

Страница 8: ...ARF370 Roof Flashing Flat to 6 12 Pitch RF371 Roof Flashing 6 12 to 12 12 Pitch CB876 Chimney Bracket AS8 Straight Attic Insulation Shield Chimney Sections Firestop Spacer JB877 Joint Band g o l a t a...

Страница 9: ...TION INSTRUCTIONS LDS33 3 x 3 LDS46 4 x 6 Decorative Shroud TR344 NATR344 Round Termination Cap TR342 Round Telescoping Termination Cap ST375 Square Termination Cap CT35 Chase Top CAK4A Chimney Air Ki...

Страница 10: ...n a basement near frequently opened doors central heat outlets or returns or other locations of considerable air movement can affect the performance and cause intermittent smoke spillage from the fron...

Страница 11: ...opening with the width shown in the Table below x 40 tall The finished cavity depth must be no less than 23 Figure 5 shows a typical framing using 2 x 4 lumber of the fireplace assuming combustible m...

Страница 12: ...fireplace location the chimney construction and necessary clearances must be considered The fireplace system and chimney components have been tested to provide flexibility in construction The followi...

Страница 13: ...Whenever the chimney penetrates a floor ceiling a firestop spacer must be installed 6 The effective height of the fireplace assembly is measured from the base of fireplace to top of starter collar See...

Страница 14: ...e what components must be selected to complete the fireplace installation d Determine the number of firestop spacers stabi lizers roof flashing etc required to complete the fireplace installation 2 Ch...

Страница 15: ...he instructions for framing on pages 10 12 Slide the fireplace into position Be sure to provide the minimum air clearance at the sides and back of the fireplace assembly 2 Placing the Protective Metal...

Страница 16: ...ion meets the stop bead on the lower section The inner flue is placed to the inside of the flue section below it The outer casing is placed outside the outer casing of the chimney section below it See...

Страница 17: ...n insulation shield should be installed when there is a possibility of insulation coming into contact with the factory built chimney system The insulation shield is installed by positioning it over th...

Страница 18: ...r See page 22 for building a chase 14 Installing the Chimney Air Kit Required in Canada When installing the chimney air kit follow the instructions provided with this accessory 13 Installing the Outsi...

Страница 19: ...replace to allow for connection of a certified gas log lighter or a decorative gas appliance with a maximum input of 100 000 BTU hour incorporating an automatic gas shut off device and complying with...

Страница 20: ...fireplace from both radiant heat and sparks The construction of and materials used for a hearth extension are shown in Figures 17 and 18 A hearth extension of this construction may be covered with an...

Страница 21: ...terials are those consisting entirely of steel iron brick tile concrete slate glass or plasters or any combination thereof c Noncombustible Sealant Material Sealants which will not ignite and burn Gen...

Страница 22: ...8 level above the fireplace assembly This reduces heat loss through the chase 4 In cold climates the walls of the chase should be insulated to the level of the false ceiling as shown in Figure 21 Thi...

Страница 23: ...Cap a Install the chimney sections up through the chase enclosure When using a TR344 NATR344 round termination cap the uppermost top section of pipe must extend 6 above the top of the chase collar to...

Страница 24: ...ey system and enclosure To protect against the effects of corrosion on those parts exposed to the weather we recommend that the chase top and termination cap be painted with a rust Figure 24 Installin...

Страница 25: ...ces for Installation in Vented Fireplaces ANSI Z21 60 When operating your fireplace the flue damper must be in the open position This fireplace was not tested and listed for use with an unvented gas l...

Страница 26: ...e a greater density than soft woods A piece of hardwood will contain about 60 more BTU s than an equal size piece of soft wood Firewood is commonly sold by the cord 128 cu ft A cord of seasoned oak ha...

Страница 27: ...od to allow air to circulate freely around and through the woodpile b Elevate the woodpile off the ground to allow air circulation underneath c The smaller the pieces the faster the drying process Any...

Страница 28: ...imney is clean and free of creosote buildup Make sure overhanging trees and branches are cut back within ten feet of the top of the chimney Ensure the chimney cap is clean and free of any buildup of s...

Страница 29: ...d If creosote has accumulated it should be removed to reduce the risk of a chimney fire 3 Chimney Cleaning If you do detect a buildup of creosote contact a qualified chimney sweep or clean it yourself...

Страница 30: ...30 17789 Rev H 07 03 NA SERIES INSTALLATION INSTRUCTIONS HOMEOWNER S NOTES...

Страница 31: ...estop Spacer 8 Installation 16 Firewood 25 26 Flue 25 Framing 11 Fuel 25 26 G Gas Codes 19 25 Gas Knockout Location 6 Gas Log Lighter Provisions 19 General Information 25 Glass Doors 5 21 26 Grate 26...

Страница 32: ...haust fans or forced air furnaces or other causes 5 use of fuels other than those specified in the Operating Instructions 6 installation or use of components not supplied with the Fireplace or any oth...

Отзывы: