background image

32

17789 Rev H

07/03

HEATILATOR WOODBURNING FIREPLACE

LIMITED WARRANTY

As part of its

20-YEAR BUYER PROTECTION PROGRAM

AS PART OF ITS 20 YEAR BUYER PROTECTION PROGRAM (“PROGRAM”), HEARTH & HOME TECHNOLOGIES

INC.  (“HHT”)

 

is  pleased  to  offer  a  Limited  Warranty  and  a  Replacement  Parts Advantage  covering  specific  components  of  your

Heatilator

â

 woodburning fireplace system ( the “Fireplace”), installed in the United States of America or Canada.  Dealers and employees

of 

HHT

 have no authority to make any warranty or authorize any remedies in addition to or inconsistent with the terms of this Program

.

Limited Warranty

HHT

  warrants  the  following  components  of  your  Heatilator  woodburning  fireplace  to  be  free  from  original  defects  in  material  and

workmanship during the applicable periods described: five years for the firebox assembly, chimney system and roof termination; two

years for refractory firebox liners; and one year for the grate, wire mesh screens, fan system, outside air system, and glass doors.  All

limited warranty periods run from the date of initial installation of your Fireplace (the “Installation Date”).  The Limited Warranty is subject

to the conditions, exclusions and limitations of liability listed below.

Replacement Parts Advantage

Under 

HHT

’s Replacement Parts Advantage, for a period of twenty years from your Installation Date of your Fireplace, if available, 

HHT

will provide you with repair or replacement parts for defective components which are no longer under their applicable Limited Warranty,

at 50% of the then current retail list price for such components.  

HHT

 shall have no responsibility for freight and labor charges related to

such parts.

Conditions, Exclusions, & Limitations of Liability

A.

Both the Limited Warranty and Replacement Parts Advantage supplied by 

HHT

 apply only while the Fireplace is in its location of

original installation.  

HHT

’s obligation under this warranty does not extend to damages resulting from (1) installation, operation or

maintenance of the Fireplace not in accordance with the Installation Instructions, Operating Instructions, and the Listing Agent

Identification Label furnished with the Appliance; (2) installation which does not comply with local building codes; (3) shipping,

improper handling, improper operation, abuse, misuse, accident or unworkmanlike repairs; (4) environmental conditions, inadequate

ventilation or drafting caused by tight sealing construction of the structure, air handling devices such as exhaust fans or forced air

furnaces,  or  other  causes;    (5)  use  of  fuels  other  than  those  specified  in  the  Operating  Instructions;  (6)  installation  or  use  of

components not supplied with the Fireplace or any other components not expressly authorized and approved by 

HHT

; and/or (7)

modification of the Fireplace not expressly authorized and approved by 

HHT

 in writing. This warranty is limited to only the component

parts manufactured or supplied by 

HHT

.

B.

During the first year of the Limited Warranty, 

HHT

 will, at its sole option, repair or replace any covered defective component and will

provide replacement parts at no charge. And will pay reasonable labor and freight costs.  During the second through the fifth years

of the Limited Warranty (if applicable), 

HHT

 will provide replacement parts free of charge for any covered defective component, but

will  not  pay  for  freight  or  labor  costs  related  to  the  shipment  of  the  parts  or  the  actual  repair  or  replacement.   After  the  fifth

anniversary of the Installation date, 

HHT

’s sole obligation and your exclusive remedy is set forth in 

HHT

’s Replacement Parts

Advantage described above.  

In no event shall HHT be liable for any incidental or consequential damages caused by defects

in your Fireplace.

C. EXCEPT TO THE EXTENT PROVIDED BY LAW, HHT MAKES NO EXPRESS WARRANTIES OTHER THAN THE   WARRANTY

SPECIFIED HEREIN. THE DURATION OF ANY IMPLIED WARRANTY IS LIMITED TO DURATION OF THE WARRANTY SPECIFIED

ABOVE.

D.

Some states do not allow exclusions or limitations of incidental or consequential damages, so those limitations may not apply to

you. This warranty gives you specific rights; you may also have other rights which vary from state to state.

How to Obtain Service

1.

To obtain service under this warranty you must:

2.

Send written notice of the claimed condition to Heatilator Technical Service Department, Hearth & Home Technologies, 1915 W.

Saunders Street, Mt. Pleasant, Iowa 52641-1563.  You may also register your claim online at www.heatilator.com/contact.asp.

3.

Provide proof of purchase, model number, serial number, and manufacturing date code to 

HHT

.

4.

Provide 

HHT

 reasonable opportunity to investigate the claim, including reasonable opportunity to inspect the Appliance prior to any

repair or replacement work and before the Appliance or any component of the Appliance has been removed from the place of

original installation.

5.

Obtain 

HHT

’s consent to any warranty work before the work is done.

ADDITIONAL INFORMATION: 

If you would like information on current HEATILATOR products or want to locate a dealer in your area,

call 1-800-843-2848.

ã

2003 Heatilator is a Registered Trademark of Hearth & Home Technologies Inc.

Содержание NA36

Страница 1: ...42 WOODBURNING FIREPLACE WARNING Improper installation adjustment alteration service or maintenance can cause injury or property damage Refer to this manual For assistance or additional information co...

Страница 2: ...r related problems that may result from the lack of adequate combustion air It is the responsibility of the builder contractor to ensure that adequate combustion air has been provided for the fireplac...

Страница 3: ...f the home If you desire to put a fireplace in your basement we recommend that you consider a direct vent gas fireplace Basements always have a significant negative air pressure that causes the firepl...

Страница 4: ...illustrations and diagrams used throughout these installation instructions are not drawn to scale Figure 1 Typical Fireplace System B DESCRIPTION OF THE FIREPLACE SYSTEM A LISTINGS AND CODE APPROVALS...

Страница 5: ...i b a C d e h c r A 6 3 0 1 P D 2 4 0 1 P D h s i n i F k c a l B s r o o D s s a l G n o i t p e c r e P B 6 3 0 1 P D B 2 4 0 1 P D h s i n i F s s a r B d e h s i l o P s r o o D s s a l G n o i t...

Страница 6: ...6 17789 Rev H 07 03 NA SERIES INSTALLATION INSTRUCTIONS Fireplace Dimensions OUTSIDE AIR KIT AK14 NAAK14...

Страница 7: ...5 1 3 L S 5 1 n r u t e R t e s f f O y e n m i h C 0 3 3 L S A N 0 3 3 L S 0 3 n r u t e R t e s f f O y e n m i h C 8 3 3 S F A N 8 3 3 S F t h g i a r t S p o t s e r i F 9 3 3 S F 5 1 p o t s e r...

Страница 8: ...ARF370 Roof Flashing Flat to 6 12 Pitch RF371 Roof Flashing 6 12 to 12 12 Pitch CB876 Chimney Bracket AS8 Straight Attic Insulation Shield Chimney Sections Firestop Spacer JB877 Joint Band g o l a t a...

Страница 9: ...TION INSTRUCTIONS LDS33 3 x 3 LDS46 4 x 6 Decorative Shroud TR344 NATR344 Round Termination Cap TR342 Round Telescoping Termination Cap ST375 Square Termination Cap CT35 Chase Top CAK4A Chimney Air Ki...

Страница 10: ...n a basement near frequently opened doors central heat outlets or returns or other locations of considerable air movement can affect the performance and cause intermittent smoke spillage from the fron...

Страница 11: ...opening with the width shown in the Table below x 40 tall The finished cavity depth must be no less than 23 Figure 5 shows a typical framing using 2 x 4 lumber of the fireplace assuming combustible m...

Страница 12: ...fireplace location the chimney construction and necessary clearances must be considered The fireplace system and chimney components have been tested to provide flexibility in construction The followi...

Страница 13: ...Whenever the chimney penetrates a floor ceiling a firestop spacer must be installed 6 The effective height of the fireplace assembly is measured from the base of fireplace to top of starter collar See...

Страница 14: ...e what components must be selected to complete the fireplace installation d Determine the number of firestop spacers stabi lizers roof flashing etc required to complete the fireplace installation 2 Ch...

Страница 15: ...he instructions for framing on pages 10 12 Slide the fireplace into position Be sure to provide the minimum air clearance at the sides and back of the fireplace assembly 2 Placing the Protective Metal...

Страница 16: ...ion meets the stop bead on the lower section The inner flue is placed to the inside of the flue section below it The outer casing is placed outside the outer casing of the chimney section below it See...

Страница 17: ...n insulation shield should be installed when there is a possibility of insulation coming into contact with the factory built chimney system The insulation shield is installed by positioning it over th...

Страница 18: ...r See page 22 for building a chase 14 Installing the Chimney Air Kit Required in Canada When installing the chimney air kit follow the instructions provided with this accessory 13 Installing the Outsi...

Страница 19: ...replace to allow for connection of a certified gas log lighter or a decorative gas appliance with a maximum input of 100 000 BTU hour incorporating an automatic gas shut off device and complying with...

Страница 20: ...fireplace from both radiant heat and sparks The construction of and materials used for a hearth extension are shown in Figures 17 and 18 A hearth extension of this construction may be covered with an...

Страница 21: ...terials are those consisting entirely of steel iron brick tile concrete slate glass or plasters or any combination thereof c Noncombustible Sealant Material Sealants which will not ignite and burn Gen...

Страница 22: ...8 level above the fireplace assembly This reduces heat loss through the chase 4 In cold climates the walls of the chase should be insulated to the level of the false ceiling as shown in Figure 21 Thi...

Страница 23: ...Cap a Install the chimney sections up through the chase enclosure When using a TR344 NATR344 round termination cap the uppermost top section of pipe must extend 6 above the top of the chase collar to...

Страница 24: ...ey system and enclosure To protect against the effects of corrosion on those parts exposed to the weather we recommend that the chase top and termination cap be painted with a rust Figure 24 Installin...

Страница 25: ...ces for Installation in Vented Fireplaces ANSI Z21 60 When operating your fireplace the flue damper must be in the open position This fireplace was not tested and listed for use with an unvented gas l...

Страница 26: ...e a greater density than soft woods A piece of hardwood will contain about 60 more BTU s than an equal size piece of soft wood Firewood is commonly sold by the cord 128 cu ft A cord of seasoned oak ha...

Страница 27: ...od to allow air to circulate freely around and through the woodpile b Elevate the woodpile off the ground to allow air circulation underneath c The smaller the pieces the faster the drying process Any...

Страница 28: ...imney is clean and free of creosote buildup Make sure overhanging trees and branches are cut back within ten feet of the top of the chimney Ensure the chimney cap is clean and free of any buildup of s...

Страница 29: ...d If creosote has accumulated it should be removed to reduce the risk of a chimney fire 3 Chimney Cleaning If you do detect a buildup of creosote contact a qualified chimney sweep or clean it yourself...

Страница 30: ...30 17789 Rev H 07 03 NA SERIES INSTALLATION INSTRUCTIONS HOMEOWNER S NOTES...

Страница 31: ...estop Spacer 8 Installation 16 Firewood 25 26 Flue 25 Framing 11 Fuel 25 26 G Gas Codes 19 25 Gas Knockout Location 6 Gas Log Lighter Provisions 19 General Information 25 Glass Doors 5 21 26 Grate 26...

Страница 32: ...haust fans or forced air furnaces or other causes 5 use of fuels other than those specified in the Operating Instructions 6 installation or use of components not supplied with the Fireplace or any oth...