1. APPLIANCE LOCATIONS AND SPACE
REQUIREMENTS
Figure 1 illustrates a variety of ways the appliance
may be located in a room. The CALIBER Series may
be installed directly on the floor or raised on a hearth.
These appliances are certified for installation in a bed-
room or a bed/sitting room in the U.S. and Canada
provided that the bedroom or bathroom have a volume
of at least 1500 cubic feet.
Common venting of this gas appliance with other gas
appliances is NOT allowed in multi-family dwellings.
12-97
4i
28887A
DUE TO HIGH TEMPERATURES, THE APPLIANCE SHOULD BE LOCATED OUT OF TRAFFIC AND
AWAY FROM FURNITURE AND DRAPERIES.
B. LOCATION AND CLEARANCES
Figure 1
Appliance Locations
A hearth extension is not required for this appliance.
2. CLEARANCES
Figure 2 shows all clearances that must be main-
tained around the appliance. See page 9 for ter-
mination cap clearances. See Figures 4 and 15
for vent clearances.
Unit Dimensions
Figure 2
Appliance Clearances to Combustible Materials
Right Hand
Side
Left Hand
Side
Model
A
B
C
36" Series
36"
41"
24
1
/
2
"
42" Series
42"
47"
30
1
/
2
"
Model
A
B
C
36" Series
50
5
/
8
" 71
5
/
8
"
42
"
42" Series
55
1
/
4
" 77
5
/
8
"
48
"