Heatilator • ECLIPSE-32, ECLIPSE-36 Owner’s Manual • 2297-985 Rev. C • 4/15
6
A. Appliance Certi
fi
cation
2
2
Product Speci
fi
c Information
Installation and service of this appliance should be
performed by quali
fi
ed personnel. Hearth & Home
Technologies suggests NFI certi
fi
ed or factory
trained professionals, or technicians supervised by
an NFI certi
fi
ed professional (www.n
fi
certi
fi
ed.org).
B. Glass Speci
fi
cations
Hearth & Home Technologies appliances manufactured
with tempered glass may be installed in hazardous lo-
cations such as bathtub enclosures as de
fi
ned by the
Consumer Product Safety Commission (CPSC). The
tempered glass has been tested and certi
fi
ed to the re-
quirements of
ANSI Z97.1
and
CPSC 16 CFR 1202
(Safety Glazing Certi
fi
cation Council
SGCC# 1595
and
1597
. Architectural Testing, Inc. Reports
02-31919.01
and
02-31917.01
).
This statement is in compliance with
CPSC 16 CFR Sec-
tion 1201.5
“Certi
fi
cation and labeling requirements”
which refers to
15
U.S. Code
(USC) 2063
stating “…Such
certi
fi
cate shall accompany the product or shall otherwise
be furnished to any distributor or retailer to whom the
product is delivered.”
Some local building codes require the use of tempered
glass with permanent marking in such locations. Glass
meeting this requirement is available from the factory.
Please contact your dealer or distributor to order.
NOT INTENDED FOR USE AS A PRIMARY HEAT SOURCE.
This appliance is tested and approved as either supplemen-
tal room heat or as a decorative appliance. It should not be
factored as primary heat in residential heating calculations.
NOTICE:
This installation must conform with local codes.
In the absence of local codes you must comply with the
National Fuel Gas Code, ANSI Z223.1-latest edition in
the U.S.A. and the CAN/CGA B149 Installation Codes in
Canada.
C. BTU Speci
fi
cations
This product is listed to ANSI standards for “Vented Gas
Fireplace Heaters” and applicable sections of “Gas Burn-
ing Heating Appliances for Manufactured Homes and
Recreational Vehicles”, and “Gas Fired Appliances for
Use at High Altitudes”.
Models
(U.S. or Canada)
Maximum
Input BTU/h
Minimum
Input
BTU/h
Ori
fi
ce
Size (DMS)
ECLIPSE-32
(NG)
(0-2000 FT)
17,500
12,000
45
ECLIPSE-32
(LP)
(0-2000 FT)
17,000
13,500
1.25 mm
ECLIPSE-36
(NG)
(0-2000 FT)
23,500
16,500
42
ECLIPSE-36
(LP)
(0-2000 FT)
20,500
16,500
54
MODELS:
ECLIPSE-32, ECLIPSE-36
LABORATORY:
Underwriters Laboratories, Inc. (UL)
TYPE:
Direct Vent Heater
STANDARD:
ANSI Z21.88-2014/CSA 2.33-2014