15
Heatilator • ECLIPSE-32, ECLIPSE-36 Owner’s Manual • 2297-985 Rev. C • 4/15
Venting
Frequency:
Seasonally
By:
Homeowner
Tools needed:
Protective gloves and safety glasses.
• Inspect venting and termination cap for blockage or
obstruction such plants, bird nests, leaves, snow, debris,
etc.
• Verify termination cap clearance to subsequent construc-
tion (building additions, decks, fences, or sheds).
• Inspect for corrosion or separation.
• Verify weather stripping, sealing and
fl
ashing remains
intact.
• Inspect draft shield to verify it is not damaged or missing.
Doors, Surrounds, Fronts
Frequency:
Annually
By:
Homeowner
Tools needed
: Protective gloves, stable work surface.
• Assess condition of screen and replace as necessary.
• Inspect for scratches, dents or other damage and repair
as necessary.
•
Vacuum and dust surfaces.
Remote Control
Frequency:
Seasonally
By:
Homeowner
Tools needed:
Replacement batteries and remote con-
trol instructions.
• Locate remote control transmitter and receiver.
• Verify operation of remote. Refer to remote control
operation instructions for proper calibration and setup
procedure.
• Place batteries as needed in remote transmitters and
battery-powered receivers.
• Place remote control out of reach of children.
If not using your
fi
replace for an extended period of time
(summer months, vacations/trips, etc), to prevent unin-
tended operation:
• Remove batteries from remote controls.
• Unplug 3 volt adapter plug on IPI models.
Figure 4.1 Fixed Glass Assembly
LATCHES
(BOTH BOTTOM
AND TOP)
GLASS
ASSEMBLY