480-1091 30 4-03
Constitution
EPA Certified Fireplace
9. Fan Replacement
Fan Cord Location
The Constitution Fireplace comes standard
equipped with two fans, installed at the
factory with electric access on the right side
of fireplace (as you face it).
Fan Replacement Instructions
Power must be OFF prior to servicing!
The fan assembly may be accessed before
or after the fireplace has been installed.
Before
Fireplace Installation:
1. Remove the 2 screws located at the
outside edge of the bottom panel as
show in Figure 30A.
2. Pull panel forward and remove from
fireplace.
After
Fireplace Installation:
1. Remove the firebrick from the bottom of
the fireplace.
2. Remove the 2 screws from the access
panel in the firebox floor.
3. Pry up the access panel using the
screwdrive slot and completely remove
the panel.
Removing the Fan Assembly
1. Unplug the wire harness.
2. Lift fan off of studs and remove. Repeat for
second fan if necessary. See Figure 30B.
3. Inspect the gasket and ensure it is in good
condition.
4. Replace with new fan.
5. Reinstall bottom panel or firebox access panel
in reverse order as descibed above.
Screwdriver Slot
Screws
Remove 2 screws and pull panel forward
(Before fireplace installation)
After
fireplace
installation
Unplug wire harness before
removing fan
Figure 30B - Fan Motor
Figure 30A - Accessing Fan Motor